6.9.1
Via Web Interface
To set the LUN’s backup mode via the Web Management Interface:
•
Click on the “Management Control Processor” graphic.
•
Click on the “LUN Config” tab.
•
Select the LUN to edit by clicking on the LUN graphic.
•
Click the “Modify LUN” button.
•
Select the backup mode from the “Backup Mode” listbox.
•
Click the “OK” button.
6.9.2
Via Text Management
To set a LUN’s backup mode via the Text Management Interface:
•
From the Telnet Main Menu, select “LUN Setup”
•
Select “Modify LUN(s)”
•
Select LUN (See instructions in Section 6.5 )
•
Select “Set backup mode for this LUN”
•
Choose the backup mode from the sub-menu and press
[ENTER]
•
Select “Exit to the LUN configuration menu”
•
To save the changes once you have completed all LUN
configuration, select “Save changes and exit”
Datasync mode
In DataSync mode, reads and writes are done to memory only. The
disk remains offline during normal operation. If power loss occurs
and the shutdown timer reaches zero, or the user requests a
shutdown, the system takes the Fibre Channel interfaces offline
and synchronizes all data to the internal hard drive.
Volatile mode (optional)
This operational mode disables the backup functionality for the LUN
making it completely volatile. In the case of system shutdown or
failure, all data stored in the selected LUN will be lost intentionally.
6.10
Initializing LUNs
The RamSan-120 allows the administrator to initialize each LUN. The
initialization process erases the first few blocks of the selected LUN to
remove any stale file system information.
6.10.1
Via Web Interface
To initialize a LUN via the Web Management Interface:
•
Click on the “Management Control Processor” graphic.
•
Click on the “LUN Config” tab.
•
Select the LUN to edit by clicking on the LUN graphic.
•
Click the “Modify LUN” button.
•
Click the “Initialize” button.
RamSan-120
User’s Manual
- 73 -