Name fan-state-notif
Description The fan state has changed
Includes
Message
Fan State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState
N/A
1 error
One or more fan channels have stopped;
temperature warnings that will cause the system
to shutdown are imminent.
2 warn
Single fans in one or more fan channels have
stopped or are running slowly. There is no
immediate danger, but the fans may need to be
serviced.
3 good
All fans are working properly.
4 warnHigh
One or more fans are spinning too fast. The
system is in no immediate danger but may need
to be serviced.
5 errorHigh
N/A
6 noDevice
N/A
7 notMonitored
Fan monitoring has been turned off to suppress
warnings.
Name disk-state-notif
Description The disk state has changed
Includes
Message
Device Number
Disk State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState
N/A
1 error
N/A
2 warn
N/A
3 good
The disk is working properly
4 warnHigh
The disk is rebuilding.
5 errorHigh
The disk has failed, or is missing from the system.
6 noDevice
N/A
7 notMonitored
Monitoring has been turned off to suppress
warnings.
RamSan-300/320/325
User’s Manual
- 117 -
Summary of Contents for 320
Page 1: ...TEXAS MEMORY SYSTEMS INC RamSan 300 320 325 User s Manual Version 2 1 ...
Page 12: ...Figure 2 1 RamSan 320 325 Layout RamSan 300 320 325 User s Manual 8 ...
Page 110: ...Figure B 3 Power Supply Module Figure A 5 Memory Blade RamSan 300 320 325 User s Manual 106 ...
Page 111: ...Figure A 6 120 Gigabyte Replacement Hard Drive RamSan 300 320 325 User s Manual 107 ...