![Texas Instruments SM320F2812-HT Data Data Manual Download Page 111](http://html.mh-extra.com/html/texas-instruments/sm320f2812-ht-data/sm320f2812-ht-data_data-manual_1097111111.webp)
Data Valid
11
SPISOMI
SPISIMO
SPICLK
(clock polarity = 1)
SPICLK
(clock polarity = 0)
Master In Data
Must Be Valid
Master Out Data Is Valid
1
7
6
10
3
2
SPISTE
(see Note A)
SM320F2812-HT
www.ti.com
SGUS062B
–
JUNE 2009
–
REVISED JUNE 2011
A.
In the master mode, SPISTE goes active 0.5tc(SPC) before valid SPI clock edge. On the trailing end of the word, the
SPISTE will go inactive 0.5tc(SPC) after the receiving edge (SPICLK) of the last data bit.
Figure 6-25. SPI Master External Timing (Clock Phase = 1)
Copyright
©
2009
–
2011, Texas Instruments Incorporated
Electrical Specifications