Step 8: For ultra-fast startup time (less than 100 ms) it is recommended to follow below steps.
• Disable auto-handoff [AUTO_HANDOFF].
• Configure Open loop handoff cycles [OL_HANDOFF_CYCLES] to 3.
• Configure INTEG_ZC_METHOD to Integration.
• Enable Dynamic degauss [DYN_DEGAUSS_EN]
• Configure open to closed loop handoff threshold [OPN_CL_HANDOFF_THR] to a value lesser than or equal
to 20 Hz.
For startup times above 100ms, it is recommended to follow below steps.
• Enable auto-handoff [AUTO_HANDOFF].
• Configure Open loop handoff cycles [OL_HANDOFF_CYCLES] to 6.
• Enable Dynamic degauss [DYN_DEGAUSS_EN]
Note
If Abnormal speed fault [ABN_SPEED] gets triggered, it is recommended to decrease open loop
acceleration constants [OL_ACC_A1] and [OL_ACC_A2] and also retune IPD by increasing the IPD
current threshold [IPD_CURR_THR] and IPD repeat times [IPD_REPEAT].
Step 9: Increase Closed loop acceleration rate [CL_ACC]
Closed loop acceleration rate [CL_ACC] can be increased until closed loop current reaches Lock detection
current threshold [LOCK_ILIMIT]. Closed loop current can be measured using oscilloscope. Increasing closed
loop acceleration rate [CL_ACC] might trigger LOCK_LIMIT. If this happens, reduce closed loop acceleration rate
[CL_ACC] until no longer triggers.
Option 2: Align
Step 1: Select align as the motor startup method in [MTR_STARTUP].
Step 2: Configure align time [ALIGN_TIME] to 5 ms.
Step 3: Follow Step 6 to Step 9 in Option 1.
Basic Controls
SLLU336 – MAY 2021
MCT8316A Tuning Guide
17
Copyright © 2021 Texas Instruments Incorporated