Quick Start
The panel on the left of the main window shows a list of control pages available to the user. Upon
selecting “Low Level Configuration” the following page will be shown.
Figure 5.
The “Low Level Configuration” page gives direct access to the internal registers of the LMP92066.
Selecting a line in the “Register Map” will bring up the “Register Data” set of controls, which lets the user
set and un-set the individual bit fields. The new values are set to the device by clicking “Write Register”
button. “Read Register” button will report the state of the selected LMP92066 register.
“Access Level” buttons send series of transfers that set the device’s memory Access Level. The default
access level is “L0”, and it gives only READ access to all internal registers.
Click “L2” prior to leaving this control page.
7
SNAU153 – MARCH 2014
LMP92066 Dual Temperature-Controlled DAC Evaluation Module
Copyright © 2014, Texas Instruments Incorporated