SNAS605AR – MARCH 2013 – REVISED DECEMBER 2015
9.7.9.7 RB_DAC_VALUE(MSB), RB_CLKinX_SEL, RB_CLKinX_LOS
This register provides read back access to CLKinX selection indicator and CLKinX LOS indicator. The 2 MSBs
are shared with the RB_DAC_VALUE. See RB_DAC_VALUE section.
Table 80. Register 0x184
BIT
NAME
DESCRIPTION
7:6
RB_DAC_VALUE[9:8]
See RB_DAC_VALUE section.
Read back 0: CLKin2 is not selected for input to PLL1.
5
RB_CLKin2_SEL
Read back 1: CLKin2 is selected for input to PLL1.
Read back 0: CLKin1 is not selected for input to PLL1.
4
RB_CLKin1_SEL
Read back 1: CLKin1 is selected for input to PLL1.
Read back 0: CLKin0 is not selected for input to PLL1.
3
RB_CLKin0_SEL
Read back 1: CLKin0 is selected for input to PLL1.
2
N/A
Read back 1: CLKin1 LOS is active.
1
RB_CLKin1_LOS
Read back 0: CLKin1 LOS is not active.
Read back 1: CLKin0 LOS is active.
0
RB_CLKin0_LOS
Read back 0: CLKin0 LOS is not active.
9.7.9.8 RB_DAC_VALUE
Contains the value of the DAC for user readback.
FIELD NAME
MSB
LSB
RB_DAC_VALUE
0x184 [7:6]
0x185 [7:0]
Table 81. Registers 0x184 and 0x185
POR
BIT
REGISTERS
NAME
DESCRIPTION
DEFAULT
RB_DAC_
DAC value is 512 on power on reset, if PLL1 locks upon power-up the DAC
7:6
0x184
2
VALUE[9:8]
value will change.
RB_DAC_
7:0
0x185
0
VALUE[7:0]
9.7.9.9 RB_HOLDOVER
Table 82. Register 0x188
BIT
NAME
DESCRIPTION
7:5
N/A
Reserved
Read back 0: Not in HOLDOVER.
4
RB_HOLDOVER
Read back 1: In HOLDOVER.
3:0
N/A
Reserved
Copyright © 2013–2015, Texas Instruments Incorporated