CPU21
(continued)
CPU Module
IDE/Compiler
Version Number
Notes
IAR Embedded Workbench
Not affected
TI MSP430 Compiler Tools (Code
Composer Studio)
v4.0.x or later
User is required to add the compiler
or assembler flag option below. --
silicon_errata=CPU21
MSP430 GNU Compiler (MSP430-
GCC)
MSP430-GCC 4.9 build 167 or later
CPU22
CPU Module
Category
Compiler-Fixed
Function
Indirect addressing mode with the Program Counter as the source register may produce
unexpected results
Description
When using the indirect addressing mode in an instruction with the Program Counter (PC)
as the source operand, the instruction that follows immediately does not get executed.
For example in the code below, the ADD instruction does not get executed.
mov @PC, R7
add #1h, R4
Workaround
Refer to the table below for compiler-specific fix implementation information.
IDE/Compiler
Version Number
Notes
IAR Embedded Workbench
Not affected
TI MSP430 Compiler Tools (Code
Composer Studio)
v4.0.x or later
User is required to add the compiler
or assembler flag option below. --
silicon_errata=CPU22
MSP430 GNU Compiler (MSP430-
GCC)
MSP430-GCC 4.9 build 167 or later
CPU37
CPU Module
Category
Functional
Function
Wrong program trace display in the debugger while using conditional jump instructions
Description
The state storage window displays an incorrect sequence of instructions when:
1. Conditional jump instructions are used to form a software loop
AND
2. A false condition on the jump breaks out of the loop
In such cases the trace buffer incorrectly displays the first instruction of the loop as the
instruction that is executed immediately after exiting the loop.
Example:
Advisory Descriptions
SLAZ669P – MAY 2015 – REVISED AUGUST 2021
MSP430FG6426 Microcontroller
7