www.ti.com
Getting Started
1.2
Quick Start Board Setup
The DRV2700EVM-HV500 comes with preprogrammed firmware to provide a 0- to 500-Vp signal between
the output and GND.
1. Out of the box, the jumpers are set to begin demo mode using USB power. The default jumper settings
are found in
Table 2
.
2. Connect a mini-USB cable to the USB connector on the DRV2700EVM-HV500 board.
3. Connect the other end of the USB cable to an available USB port on a computer, USB charger, or USB
battery pack.
4. If the board is powered correctly, the 5-V LED is on.
5. Enable the output using the GUI or programmatically through the computer, see
GUI Interface
for
additional assistance. If using an external input signal, EN the output by changing the jumper (JP3) or
equivalent control signal.
6. Once the output is EN, the device allows for the high-voltage output.
Table 2. Default Jumper Settings
Jumper
Parameter
Default
Specification
Setting
Open
Disconnected PWM input and I/O of MSP430
JP1 PWM
Connected
X
Connected PWM input and I/O of MSP430
Open
DRV2700 not connected to either power supply
JP4 DRV
VIN
(1)
DRV2700 connected to VIN power supply
USB
(1)
X
DRV2700 connected to USB power supply
Open
EN pulled internally to GND through DRV2700 internal resistance
JP3 EN
PU
(1)
EN pulled up to MSP power supply through external pull up resistor
MSP
(1)
X
EN tied to I/O of MSP430
Open
DRV2700 not connected to either power supply
JP4 DRV
VIN
(1)
DRV2700 connected to VIN power supply
USB
(1)
X
DRV2700 connected to USB power supply
(1)
In the table, jumper setting name means that side of the terminal is connected to the middle of the 3-terminal header. For
questions, refer to
Figure 1
.
1.3
Connecting a Load
1. With the power supply off, connect the negative terminal of the load to GND and connect the positive
terminal of the load to the "HIGH VOLTAGE" side of JP2.
2. Ensure the terminals are connected correctly, then enable the supply
CAUTION
Before connecting the load, ensure that the load is rated for the selected output
voltage. If not, see the
Programming the HV Maximum Output Voltage
section
to adjust the DRV2700 maximum output voltage.