Specify DAC
sampling rate
Set tone output
frequency
Press ‘Create and
Save/Run
TSW3100’ to load
data into TSW3100
Specify serial LVDS
as data format
Ensure match on data format with
AFE722x setup (e.g. 2s complement)
Select ‘Load and
Run’ option
Initial EVM Setup and Basic Test Procedure
The DAC output should show something like this on the spectrum analyzer (example with sample rate =
122.88 MSPS, input tone = 10 MHz).
8
EVM Description
SLOU330
–
December 2011
Copyright
©
2011, Texas Instruments Incorporated