Models with magnetic clamping device
Place a filled concrete mould on the vibratory plate of the table.
Set the desired vibration time (from a minimum of 1 second to a maximum of 9,999 sec-
onds)
Start the vibration function by using the START/STOP button.
After the pre-selected time has elapsed, or if the Operator presses the STOP button be-
fore this time has run out, the vibration function will stop.
5.
How to set the timer switch ST64-31.07
5.1 General description
The microprocessor-controlled timer switch is equipped with a timer with a simple START-
STOP function. When the timer switch is turned on, it displays the time at which it will run
out (the setpoint value). The Operator uses the downward button (
) and the upward
button (
) to set the required value for the timer. When the Operator presses the START-
STOP button, the time begins to run. When the elapsed time reaches the setpoint value,
the timer switch will switch off the Vibrating Table. When the time has run out, the auto-
matic-reset function will return the timer switch back to its starting state.
After the timer has started, it can be interrupted at any time and returned to its starting
state. To do this, the Operator presses the START-STOP button.
5.2 Setting the timer-switch parameters
Connect the Vibrating Table with Timer Switch to the power source.
Press the downward button (
) and the upward button (
) at the same time and hold
both buttons down for at least four (4) seconds. The display will then show the param-
eter list for timer-switch parameters (beginning with P1).
Use the upward button (
) to page upward in the list, and use the downward button
(
) to page downward.