Safety Summary

 

 

To avoid personal injury and/or product damage, review and comply  
with the following safety precautions. These precautions apply to both operating and 
maintenance personnel and must be followed during all phases of operation, service, 
and repair of this probe.

 

 

WARNING

 statement calls attention to an operating procedure, practice, 

or condition, which, if not followed correctly, could result in injury or death to 
personnel.

 

  

CAUTION

  statement  calls  attention  to  an  operating  procedure,  practice,  or 

condition, which, if not followed correctly, could result in damage to or destruction 
of parts or the entire product.

 

  

Do Not Work Alone

 

Do not work alone when working with high voltages.

 

 

Inspect the Probe

 

Inspect the probe and accessories for cracks and frayed or broken leads before each 
use. If defects or damages are noted, DO NOT USE the probe.

 

 

Dry Conditions

 

Hands, shoes, floor, and work bench must be dry. Avoid making 
measurements under humidity, dampness, or other environmental conditions 
that might affect safety.

 

 

Do Not Remove the Probe’s Casing

 

Removal of the probe’s casing may expose you to electric shock. If necessary, 
disconnect the inputs and outputs of the probe before opening the case.

 

 

Hazardous Contact

 

To avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do 
not touch exposed connections and components when power is present.

 

 

Unexpected Charges

 

Hazardous voltages may be present in unexpected locations in circuitry being 
tested when a fault condition in the circuit exists.

 

Capacitors inside the instrument may retain a charge even if the instrument is 
disconnected from its source of supply.

 

 

Use Only in Office-Type Indoor Setting

 

The probe is designed to be used in office-type indoor environments.  
Do not operate the probe:

 

 

 

In the presence of noxious, corrosive, flammable fumes, gases, vapors, 
chemicals, or finely-divided particulates.

 

 

 

In environments where there is a danger of any liquid 

spilled

 on the probe.

 

 

In air temperatures exceeding the specified operating

 

temperatures.

 

 

In atmospheric pressures outside the specified altitude limits or

 

where the 

surrounding gas is not air.

 

 
 
 

Summary of Contents for TT-SI 8000 Series

Page 1: ...ACTIVE DIFFERENTIAL PROBES INSTRUCTION MANUAL TT SI 8000 SERIES...

Page 2: ......

Page 3: ...idity dampness or other environmental conditions that might affect safety Do Not Remove the Probe s Casing Removal of the probe s casing may expose you to electric shock If necessary disconnect the in...

Page 4: ...king voltage ranges See specifications on page 7 Use Proper Power Source Do not operate this probe from a power source that applies more than the voltage specified Must be Grounded This probe is groun...

Page 5: ...in the test set up Compliance Statements EC Declaration of Conformity The product conforms to the applicable European Union requirements per IEC 61010 031 2015 Safety requirements for electrical equip...

Page 6: ...rm High accuracy 2 Powered through USB or USB to mains adapter Over range indicator LED Initial Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An...

Page 7: ...ring instrument Getting Started 1 Connect the BNC output connector to the vertical input of a general purposed oscilloscope The oscilloscope must have a ground referenced 2 Connect power through USB o...

Page 8: ...fferential Voltage Common Mode Voltage and Maximum Input Voltage to Earth Overrange Indicator Attenuation Selection Button and Indicators Bandwidth Limit Button and Indicators Audible Overrange On Off...

Page 9: ...V 7000V Maximum Input Voltage each Side to Ground Vrms 450V CAT II 600V 600V CAT III 1000V CAT II 600V CAT III 1000V CAT II 1000V CAT III 2300V Input Impedance Single Ended to Ground 2 5M 5M 5M 20M Be...

Page 10: ...Man_8000_0120 www testec de 8 5 Voltage Derating Curve Derating Curve TT SI 8071 TT SI 7005 Voltage Derating Derating Curve TT SI 8050 8051 8052...

Page 11: ...Man_8000_0120 www testec de 9 Derating Curve TT SI 8110 Derating Curve TT SI 8010A 8010B...

Page 12: ...d 1000V CAT III 600V CAT IV 1000V CAT III 600V CAT IV TT SI GR82 Pincer Clips TT SI GR81 Hook Clips one pair black and red one pair black and red 1000V CAT III 1000V CAT III TT SI TL8 Extension Test L...

Page 13: ...ecessary clean the case with a soft cloth WARNING Dry the probe thoroughly before attempting to make voltage measurements CAUTION Avoid immersing or using abrasive cleaners or solvents containing Benz...

Page 14: ...will not be covered by this warranty Testec Elektronik GmbH reserves the right to discontinue models change specifications price or design of this device at any time without notice and without incurri...

Page 15: ...Man_700_0919 www testec de 1...

Page 16: ...obe User s Manual 2020 TESTEC Elektronik GmbH All rights reserved Unauthorized duplication of TESTEC documentation materials is strictly prohibited Customers are permitted to duplicate and distribute...

Reviews: