4.2.8 FP1
The connector for MINICUBE2.
MINICUBE2 switch setting
4.2.9
CON2
Usually the jumper is short-circuited. If you want to measure the current
consumed on the RF boards, you can measure it here.
4.2.10
U1
U1 is a temperature sensor.
The temperature sensor is being connected to the MCU pin of "P27/ANI7".
Therefore you can measure the output of the sensor using the analogue to
digital converter, embedded in the MCU. You can convert the measured output
voltage to a tempareture, referring to the conversion formul, available in the
datasheet of the sensor, SII S-80120CNB. Please download the datasheet of
the sensor from the internet web site of Seiko Instruments.
4.3
Universal Area
The kit has the universal area. Users can use this to develop custom circuit.
4.4
Solder-short pad
With using the solder-short pad to cut the circuit, users can customize the circuit.
The solder-short pad looks like the picture below.
To open, use cutter to cut the dent part. To short, put solder on the pad.
Solder-short
pad
Solder-short
pad
(Open)
(Short)
M1, T
Solder-short pad name
Before
Shipment
Connection
1M
Ω
Pull-down
P
150
~
P153
Short
Open when
P
150
~
P153 on CN1 is
used.
- 85 -