61
5 TECHNICAL DATA
5.1 Technical specifications
5.1.1 NSG 5500
Instrument power supply:
100 to 120 VAC ±10%, 47 - 63 Hz
220 to 240 VAC ±10%, 47 - 63 Hz
DUT supply:
From an external source, e.g. battery or PA 5840 power amplifier / battery
simulator
Computer interface:
IEEE 488 (recommended) USB
Input DC voltage range:
60 V max.
DC current:
100 A (250 A for 200 ms)
Voltage drop of battery
< 2 V @ 100 A
Switch:
~ 1.5 V @ 25 A
(for positive serial coupled pulses in battery mode upc (under program
control): 3.5 V @ 100 A)
Battery switch on/off time:
~ 2 µs (1Ω load)
Protection class:
IP20
5.1.2 MT 5511
Micro transient generator for the pulses 1, 2, 6 and variants.
Pulse
Voltage range
(v)
Rise tim
Pulse
width
Internal
Ri (Ω)
Repetition rate
t1 (s)
Polarity
Ext. Ri
available
Pulse 1
0-330 (1 V steps) 1 µs, 2 µs, 3 µs 2 ms, 6 ms
40, 10, 20,
30, 50 , 90
0,5-60 (0,01 steps)
Neg., Pos.
NO
0-200 (1 V steps) 1 µs
2 ms
10
0,5-60 (0,01 steps) Neg., Pos.
No
0-600 (1 V steps) 1 µs, 3 µs
1 ms
20, 50
0,5-60 (0,01 steps) Neg., Pos., BNC Yes
Pulse 1
(24 V)
0-600 (1 V steps) 1 µs, 3 µs
2 ms, 2.3 ms 10, 20, 30,
50
0,5-60 (0,01 steps)
Neg., Pos., BNC Yes
Pulse 2a
0-330 (1 V steps) 1 µs
50 µs
2, 4, 10,
20, 50, 90
0,5-60 (0,01 steps)
Neg., Pos., BNC Yes
Pulse 6
0-330 (1 V steps) 60 µs
300 µs
30
0,5-60 (0,01 steps) Neg., Pos., BNC Yes
Others
0-330 (1 V steps) 1 µs
50 µs, 35 µs
2, 50
0,5-60 (0,01 steps) Neg., Pos., BNC Yes
0-330 (1 V steps) 1 µs
50 µs, 150 µs
200µs, 350 µs
40, 10, 30 0,5-60 (0,01 steps)
Neg., Pos., BNC Yes
0-330 (1 V steps) 2 µs
50 µs
10
0,5-60 (0,01 steps) Neg., Pos., BNC Yes
Table 5–1: Technical specifications MT 5511
Note! Repetition rate of 0.2 are only valid for negative pulses or positive pulses with batter ”ON”.
Note! Pulse 1 and pulse 2a are used here for easy reference. All pulses from the MT 5511 can be both positive or negative.