2-3
Page 4
TESCO EQUIPMENT LLC
ML50-20 MAINTENANCE LIFT
Stabilizers will not extend.
Vehicle not in lift mode (Parking brake off)
Emergency stop activated
Circuit breaker tripped or blown fuse
Defective solenoid coil or relay
Damaged wiring or bad ground
Damaged or defective control switch
Defective valve cartridge
Damaged Power Take Off (P.T.O.) or pump drive
components
Emergency lowering handpump is not operating.
Manual overrides not open
Upper controls will not operate with the vehicle's
engine running.
Vehicle not in lift mode (Parking brake off)
Stabilizers not fully deployed
Emergency stop activated
Circuit breaker tripped or blown fuse
Damaged or defective control switch
Defective solenoid coil or relay
Damaged wiring or bad ground
Damaged Power Take Off (P.T.O.) or pump drive
components
Vehicle’s engine will not turn off when the ENGINE
STOP SWITCH on the upper control station is
actuated.
Damaged or defective control switch
TROUBLESHOOTING
TROUBLE
PROBABLE CAUSE
May 08
Property of American Airlines
Summary of Contents for ML50-20
Page 5: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 13: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 19: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 27: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 41: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 43: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...