2-2
Page 4
TESCO EQUIPMENT LLC
ML50-20 MAINTENANCE LIFT
2.
HYDRAULIC ADJUSTMENTS - HYDRAULIC POWER MODULE
ITEM
FUNCTION
SETTING
PROCEDURE
A Pressure Gauge
N/A
Used for reading system pressures.
B
Lift Down Speed
Control
60 sec
+/- 10
-- Raise lift fully. Activate lift down function and record the time
it takes the lift to lower fully (not including stabilizer retract).
-- Adjust valve to increase/decrease lift lower speed. Loosen
locknut and turn valve clockwise to slow lift speed, counter-
clockwise to increase lift speed. Tighten locknut when
adjustment is complete.
C
Main Relief
1800 PSIG
+/- 25
-- With the engine running, extend the stabilizers to the
maximum and hold control in “Extend”. Read the pressure at
the gauge.
-- To adjust the pressure, loosen the locknut on valve. Turn
valve clockwise to increase pressure, counter-clockwise to
lower pressure. Tighten locknut when adjustment is
complete.
D
Stabilizer Speed
Control
(Left Rear Stab.)
N/A
-- Make certain that left rear stabilizer is last to fully extend and
last to fully retract.
-- Loosen locknut and turn valve clockwise to slow stabilizer
speed, counter-clockwise to increase stabilizer speed.
Tighten locknut when adjustment is complete.
E
Stabilizer
Pressure
Reducing Valves
N/A
-- Fully retract lift and stabilizers. Turn valve fully clockwise and
extend/retract stabilizers till all stabilizers operate smoothly
and consistently with the left rear stabilizer last to extend and
last to retract (See Adjustment D).
-- Then turn valve counter-clockwise till chassis is lifted
between 1 & 2 in. (2.54 cm & 5.08 cm). Fully retract
stabilizers between adjustments. Chassis must be level +/- 1
in. (2.54 cm) side to side.
F
Stabilizer
Pressure Switch
(Left Rear)
N/A
-- Ensure Stabilizer Pressure Switch still just activates when
stabilizers are extended. Screw in adjustment to increase the
pressure needed to activate the switch. Screw out to
decrease.
-- Retract stabilizers and verify pressure switch deactivates.
G
Lift Pressure
Adjustment Valve
900 PSIG
+/- 25
-- Add pressure gauge in-line to back of valve when testing for
pressure
-- Fully extend lift and read pressure on gauge.
-- Loosen the locknut and turn valve clockwise to increase
pressure and counter-clockwise to lower pressure. Tighten
locknut when adjustment is complete.
Jan. 14
Property of American Airlines
Summary of Contents for ML50-20
Page 5: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 13: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 19: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 27: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 41: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...
Page 43: ...THIS PAGE INTENTIONALLY LEFT BLANK P r o p e r t y o f A m e r i c a n A i r l i n e s ...