4-6 Continuity Measurements 

(1)  Connect red test lead to “ V

Ω

” terminal and black test lead to 

“ COM” terminal. 

(2)  Set Range Switch to the 

 

 

position, and press 

 

 

button to 

 function. 

(3)  Remove power from the circuit being tested and discharge all 

capacitors. 

(4)  Connect the Test Lead to the circuit being measured. 
(5)  When the impedance between the test terminal is lower than 20

Ω

, it will activate a continuous beeper. 

Note: 

Continuity Test is available to check open/short of the circuit. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

12 

5. BATTERY & FUSE REPLACEMENT 

 

WARNING

 

To prevent electrical hazard or shock, turn off multi-meter and 
disconnect test leads before removing back cover.

 

 

5-1 Battery Check-Up & Replacement 

(1)  As battery power is not sufficient, LCD will display “ 

 

". 

Replacement of Two new batteries type AAA 1.5V is required. 

(2)  Set Range Switch to “ OFF “ position. Use a screw drive to 

remove the rear cover. Take out the battery and replace them 
with two new batteries of type AA 1.5V. 

(3)  Place back the rear cover and secure it with the original screw. 

 
 

5-2 FUSE Replacement 

(1)  Set Range Switch to “ OFF “ position. Use a screw drive to 

remove rear cover. Take out the malfunction fuse and replace it 
with a new fuse rate 0.5A/250A ( or 20A/600V ) of fast blow type. 

(2)  Place back the rear cover and secure it with the original screw. 

 
 
 
 
 
 

13 

Summary of Contents for TES-2700

Page 1: ... bus bars Accidental contact with the conductor could result in electric shock Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Read the operating instructions before use and follow all safety information Caution when working with voltages above 60V DC or 30 V AC RMS Such voltages pose a shock hazard Before taking resistance measurements...

Page 2: ...rasives or solvents on this instruments Operating Principle Dual slope integration Numerical Display 3 1 2 digit liquid crystal display LCD maximum reading 3260 and Bargraph indication 2 Display Symbol Definition Decimal point AC Alternating current or voltage DC Direct current or voltage V Voltage mV Millivolt 1 10 3 volt A Ampere amps Current mA Milliampere 1 10 3 amp Ω Ohm Resistance KΩ Kilohm ...

Page 3: ...V 1V 0 8 2 10MΩ AC DC 750V 4 AC Voltage 40Hz 400Hz Autorange Manual range Range Resolution Accuracy Input Impedance Overload Protection 3 2V 100uV 11MΩ 32V 1mV 320V 10mV 600V 1V 1 2 4 10MΩ AC DC 750V DC Current uA mA Autoranging Manual Range Range Resolution Accuracy Burden Voltage Overload Protection 320uA 0 1uA 0 2V max 3200uA 1uA 1 8V max 32mA 10uA 1 2V max 320mA 100uA 1 2 1 8V max 0 5A 250V fa...

Page 4: ...100Ω 3 2MΩ 1KΩ 0 8 2 30MΩ 10KΩ 1 5 3 1 3V 660Vrms Diode Test Range Resolution Short Circuit Current Accuracy Open Circuit Voltage Overload Protection 1mV 0 8mA typical 1 2 3V 660Vrms Audible Continuity Range Resolution Max Open Circuit Voltage Overload Protection 20Ω 1 3V 660Vrms 6 4 PARTS CONTROLS 4 1 Name of Parts and Positions Fig 1 7 ...

Page 5: ...t range the meter wraps around to the lowest range To exit the Manual Range mode and return to Auto Range mode Press and hold down RANGE for 2 seconds the AUTO annunciator turns back on 6 AC DC Current Select and select Button a To select function DC or AC current b To select continuity measurements or Diode tests 7 Date Hold Button Press it once to hold the measured value in dark place when readi...

Page 6: ...black test lead on the negative side and the red lead on the positive side being measured 4 Apply power and read the Current value on LCD 10 4 4 Diode Tests WARNING Before taking any in circuit measurement remove power from the circuit being tested and discharge all capacitors in the circuit 1 Connect red test lead to the VΩ terminal and black test lead to the COM terminal 2 Set range switch to th...

Page 7: ... hazard or shock turn off multi meter and disconnect test leads before removing back cover 5 1 Battery Check Up Replacement 1 As battery power is not sufficient LCD will display Replacement of Two new batteries type AAA 1 5V is required 2 Set Range Switch to OFF position Use a screw drive to remove the rear cover Take out the battery and replace them with two new batteries of type AA 1 5V 3 Place ...

Page 8: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net Home page http www tes com tw Feb 2002 4 ...

Page 9: ......