IFM8-IA and IFM8-I Industrial Mux User’s Guide

 

Ver. 1.9 

 

 

 

BASF Corporation 

Temperature Sensing Group 

46820 Fremont Blvd. 

Fremont, CA  94538-6540 

Phone: (510) 490-2150 

Fax: (510) 252-1871 

BASF Corporation 

Temperature Sensing Group 

4011 SE International Way, Suite 604 

Portland, OR 97222 

Phone: (503) 794-4073 

Fax: (503) 794-5591 

 

http://www.catalysts.basf.com/tempsensing

 

 

Copyright© 2014 BASF Corporation.  All rights reserved. 

 

Exactus and TemperaSure are registered trademarks of BASF Corporation.  The data contained in this publication are based on our current 
knowledge and experience. In view of the many factors that may affect processing and application of our product, these data do not relieve 
processors from carrying out their own investigations and tests; neither do these data imply any guarantee of certain properties, nor the suitability of 
the product for a specific purpose. Any descriptions, drawings, photographs, data, proportions, weights, etc. given herein may change without prior 
information and do not constitute the agreed contractual quality of the product. It is the responsibility of the recipient of our products to ensure that 
any proprietary rights and existing laws and legislation are observed.  

Although all statements and information in this publication are believed to be accurate and reliable, they are presented gratis and for guidance only, 
and risks and liability for results obtained by use of the products or application of the suggestions described are assumed by the user. NO 
WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET 
FORTH. Statements or suggestions concerning possible use of the products are made without representation or warranty that any such use is free of 
patent infringement and are not recommendations to infringe any patent. The user should not assume that toxicity data and safety measures are 
indicated or that other measures may not be required. ©2014 BASF Corporation. 

Summary of Contents for EXACTUS IFM8-I

Page 1: ...weights etc given herein may change without prior information and do not constitute the agreed contractual quality of the product It is the responsibility of the recipient of our products to ensure th...

Page 2: ...ault Parameters 4 Configuration Communication 5 Configuration Menu 6 Alarm Configuration 7 Analog Output Wiring 8 Mounting 9 Maintenance 10 Warnings Appendix 1 MODBUS TCP Implementation 1 Product Over...

Page 3: ...2 Figure 1 1 IFM8 IA Balloon View Note Pyrometer channel numbering sequence varies on some hardware configurations...

Page 4: ...3 Figure 1 2 IFM8 IA Overview...

Page 5: ...tts 600mA 24VDC Pin Assignments Pin 1 V Pin 2 V circuit ground Pin 3 earth chassis ground Terminal Type Removable 3 pin 5 00 5 08mm plug NOTE Relay drive current 17mA for each relay is not factored in...

Page 6: ...d Ethernet Ports 23 Telnet Port for configuration 502 Modbus TCP Port 6789 Mux Server Port 6790 UDP Announcement Port Pyrometer Ports Number of input Ports channels 8 Connectors RJ 45 Pin Assignments...

Page 7: ...utput Ripple 0 003 of Full Scale Reverse Polarity Protection Yes up to 85V Over Current Protection Yes limited to 40mA Maximum Voltage At Output Pins 48VDC 24VDC recommended Minimum Voltage At Output...

Page 8: ...imits are exceeded Pyrometers will remain powered down until power to the Industrial Mux is cycled off and back on The Pyrometer Supply Voltage is set to 6200mV adequate for standard pyrometer power c...

Page 9: ...e of any LAN type 2 Set the IP address of the PC a Right click on My Network Places and choose Properties from the pop up menu See Figure 4 1 Figure 4 1 Selecting Properties of My Network Places b Dou...

Page 10: ...9 c The following screen Figure 4 3 will appear Click the Properties button Figure 4 3...

Page 11: ...10 d Double click the Internet Protocol TCP IP line Figure 4 4 this will bring up the screen shown in Figure 4 5 Figure 4 4 Figure 4 5...

Page 12: ...not be the last number of the Industrial Mux e g if the Default Address is used this would be 80 iii The last number of the Default Gateway must be 1 iv The Subnet Mast must be 255 255 255 0 as shown...

Page 13: ...the TCP IP Winsock option from the Connect using drop down box then enter the Mux s IP address and click OK See Figure 4 8 Figure 4 8 d When you hit the OK buttons you should get the menu shown in Fi...

Page 14: ...ustrial Mux f HyperTerminal may not automatically display user keystrokes to the screen To turn on the echo feature press the Properties button circled in red in Figure 4 10 below and select the Setti...

Page 15: ...14 Figure 4 10 Check the Echo typed characters locally check box and close the dialog windows Figure 4 11...

Page 16: ...d remain at default value of 6200mv Mode Options Used to configure the alarms for individual pyrometers More detail is provided in Alarm Configuration section Mux Ambient Alarm Configuration Brings up...

Page 17: ...Menu See Figure 4 9 will bring up the Alarm configuration menu shown in Figure 6 1 Pyrometer Internal Temperature Selecting Option 3 brings up the Pyrometer Internal Temperature configuration setup sc...

Page 18: ...17 Figure 6 1 Alarm configuration menu Figure 6 2 Pyrometer Internal Temperature Alarm Configuration Menu...

Page 19: ...d to do so energize one of the relays When the Pyrometer Analog Watchdog Item 4 in Figure 6 1 is enabled then item 5 Pyrometer Watchdog Actions should be configured This offering has a self explanator...

Page 20: ...xternally Many data logging systems are configured to supply this voltage if yours is not you can use the same power supply driving the Industrial Mux to provide the power This is outlined in the sche...

Page 21: ...ount top tabs and pull the instrument away for the rail It is recommended that the Mux be mounted in a cabinet or NEMA enclosure rated for area of use See mounting examples in section 8 1 8 1 Electron...

Page 22: ...Cooling Air Inlet Valve D Covered Punch out holes for Power Input and Signal Output Cables E Pyrometer Channel Expansion Locations F Conduit Contains either the fiber optic transmission or power data...

Page 23: ...may affect the temperature measurement accuracy If the temperature exceeds 80 C failure is possible Use radiation shielding or the optional purge air to keep the electronics cool Periodically check M...

Page 24: ...aging_Implementation_Guide_V1_0b pdf TCP IP Port MODBUS TCP is implemented over port 502 the standard port number for MODBUS TCP MODBUS Addressing Each MODBUS device has an 8 bit address All of the py...