SAFETY INFORMATION

The following safety information must be observed to

ensure maximum personal safety during the operation of

this meter:

Use the meter only as specified in this manual or the

protection provided by the meter might be impaired.Test

the meter on a known voltage before using it to

determine if hazardous voltages are present.

Do not use the meter if the meter or test leads look

damaged, or if you suspect that the meter is not

operating properly. Never ground yourself when taking

electrical measurements. 

Do not touch exposed metal pipes,outlets, fixtures, etc.,

which might be at ground potential. Keep your body

isolated from ground by using dry clothing, rubber shoes,

rubber mats, or any approved insulating material. Turn off

power to the circuit under test before cutting,

unsoldering, or breaking the circuit. Small amounts of

current can be dangerous. Use caution when working

above 60V DC or 30V AC rms. Such voltages pose a

shock hazard.

When using the probes, keep your fingers behind the

finger guards.

Measuring voltage which exceeds the limits of the

multimeter may damage the meter and expose the

operator to a shock hazard. Always observe the meter

voltage limits as stated on the front of the meter.

SPECIFICATIONS

Display: 3½ digit liquid crystal display (LCD) with a

maximum reading of 1999

Polarity: Automatic, positive implied, negative polarity

indication

Overrange: (OL) or (-OL) is displayed

Zero: Automatic

Low battery indication: The "

" is displayed when the

battery voltage drops below the operating level

Measurement rate: 2 times per second, nominal

Auto power off: Approx. 10 minutes

Operating environment:

0°C to 50°C at < 70% relative humidity

Storage temperature: 

-20°C to 60°C at <  80% relative humidity

Accuracy: 

Stated accuracy at 23°C ± 5°C, <75% relative humidity

Temperature Coefficient: 0.1 × (specified accuracy)

per °C. (0°C to 18°C, 28°C to 50°C)

Altitude: 6561.7 Feet (2000m)

Power: 1.5V batteries x2, R03/SIZE AAA

Battery life: 200 hours typical with carbon-zinc

Dimensions: 145mm (H) × 70mm (W) × 34mm (D)

Weight: Approx. 11.1 oz. (315g) including holster

Accessories: One pair test leads, 1.5V battery x2

(installed) and Operating Instructions

DC VOLTS

Ranges: 200mV, 2V, 20V, 200V, 600V

Resolution: 0.1mV

Accuracy: ±(1.0% rdg + 2 dgts)

Input impedance:

200mV: >100M

Ω

: 2V:10M

Ω 

20V ~ 600V:9.1M

Ω

Overload protection: 600VDC or AC rms

AC VOLTS (50Hz - 500Hz)

Ranges: 200mV, 2V, 20V, 200V, 600V

Resolution: 0.1mV

Accuracy:

±(2.0% rdg + 5 dgts) 50Hz ~ 100Hz on 200mV range

±(2.0% rdg + 5 dgts)

Input impedance:

200mV:>100M

Ω

: 2V:10M

Ω

20V ~ 600V:9.1M

Ω

Overload protection: 600V DC or AC rms 

CURRENT

Ranges: 10A

Resolution: 0.01A

DC accuracy: ± (3.0% rdg + 3 dgts)

AC accuracy: (50Hz ~ 500Hz) ± (3.5% rdg + 5 dgts)

Voltage burden: 0.2V

Input protection:10A/500V fast blow ceramic fuse

RESISTANCE

Ranges: 200

Ω

, 2k

Ω

, 20k

Ω

, 200k

Ω

, 2M

Ω, 

20M

Ω

Resolution: 0.1

Ω

Accuracy:

±(1.5% rdg + 4 dgts) on 200

Ω

to 200k

Ω

ranges

±(2.5% rdg +4 dgts) on 2M

Ω

range

±(5.0% rdg + 5 dgts) on 20M

Ω

range

Open circuit volts: -0.45Vdc (-1.2Vdc on 200

Ω

range)

Overload protection: 500V DC or AC rms

DIODE  TEST

Test current: 1.0mA (approximate)

Accuracy: ±(3.0% rdg + 3 dgts)

Resolution: 10mV

Audible indication: <0.25V

Open circuit volts: 3.0Vdc typical

Overload protection: 500VDC or AC rms

CONTINUITY

Audible indication: Less than 25

Ω

Response time: 500ms

Overload protection: 500VDC or AC rms

MM39