4-2 DC/AC Voltage Measurements 

WARNING

 

Maximum Input Voltage at DC/AC Voltage Range is 600V 
AC/DC.  Do not attempt to take any voltage measurement 
that may exceed to avoid electrical shock hazard and/or 
damage to this instrument.

 

(1)  Connect red test lead to “ V

Ω

” terminal and black test lead to 

“ COM ” terminal. 

(2)  Set Range Switch to 

V

 or 

V

range. 

(3)  Connect the test leads IN PARALLEL to the circuit being 

measured. 

(4)  Read the Voltage value on LCD. 

 
4-3 DC/AC Current Measurement  

WARNING

 

Continuous measurements can be applied in 10A Range. 
less that 30 seconds per measurements can be applied in 
20A Range.

 

(1)  Connect red test lead to the “mA/uA“ Terminal for Current 

measurements up to 320mA.  (For measuring Current between 
320mA to 20A, Connect red test lead to “20A” terminal. ) 

Connect black test lead to “COM” terminal. 

(2)  Set Range Switch to desired A range.  and press AC/DC switch 

to DC/AC function. 

(3)  Cut the power to the circuit to be tested and Connect the 

instrument IN SERIES with the circuit with the black test lead on 
the negative “

” side and the red lead on the positive “

“ side 

being measured. 

(4)  Apply power and read the Current  value on LCD. 

10 

4-4 Diode Tests  

WARNING

 

Before taking  any in-circuit  measurement, remove  power  from 
the circuit being tested and discharge all capacitors in the circuit.

 

(1)  Connect red test lead to the " V

Ω

 " terminal and black test lead to 

the " COM" terminal. 

(2)  Set range switch to the diode test " 

 " position and press 

 

 

button to 

 

function. 

(3)  Connect the red test lead to the anode side and black test lead to 

the cathode side of the diode being tested. 

(4)  Read forward voltage (Vf) Value on LCD. 
(5)  If the polarity of test leads are reversed with diode polarity (3), the 

digital reading should nearly equal to the reading in the open 
circuit condition. This can be used for distinguishing anode and 
cathode poles of a diode. 

 

4-5 Resistance Measurement 

WARNING

 

Before taking any in-circuit resistance measurement, remove 
power from the test circuit being tested and discharge all 
Capacitors.

 

(1)  Connect red test lead to “ V

Ω

 “terminal and black test lead to 

“ COM” terminal. 

(2)  Set Range Switch to 

Ω

 range. 

(3)  Connect test lead to the circuit being measured and read the 

resistance Value on LCD. 

11 

Summary of Contents for TES-2700

Page 1: ... bus bars Accidental contact with the conductor could result in electric shock Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Read the operating instructions before use and follow all safety information Caution when working with voltages above 60V DC or 30 V AC RMS Such voltages pose a shock hazard Before taking resistance measurements...

Page 2: ...rasives or solvents on this instruments Operating Principle Dual slope integration Numerical Display 3 1 2 digit liquid crystal display LCD maximum reading 3260 and Bargraph indication 2 Display Symbol Definition Decimal point AC Alternating current or voltage DC Direct current or voltage V Voltage mV Millivolt 1 10 3 volt A Ampere amps Current mA Milliampere 1 10 3 amp Ω Ohm Resistance KΩ Kilohm ...

Page 3: ...V 1V 0 8 2 10MΩ AC DC 750V 4 AC Voltage 40Hz 400Hz Autorange Manual range Range Resolution Accuracy Input Impedance Overload Protection 3 2V 100uV 11MΩ 32V 1mV 320V 10mV 600V 1V 1 2 4 10MΩ AC DC 750V DC Current uA mA Autoranging Manual Range Range Resolution Accuracy Burden Voltage Overload Protection 320uA 0 1uA 0 2V max 3200uA 1uA 1 8V max 32mA 10uA 1 2V max 320mA 100uA 1 2 1 8V max 0 5A 250V fa...

Page 4: ...100Ω 3 2MΩ 1KΩ 0 8 2 30MΩ 10KΩ 1 5 3 1 3V 660Vrms Diode Test Range Resolution Short Circuit Current Accuracy Open Circuit Voltage Overload Protection 1mV 0 8mA typical 1 2 3V 660Vrms Audible Continuity Range Resolution Max Open Circuit Voltage Overload Protection 20Ω 1 3V 660Vrms 6 4 PARTS CONTROLS 4 1 Name of Parts and Positions Fig 1 7 ...

Page 5: ...t range the meter wraps around to the lowest range To exit the Manual Range mode and return to Auto Range mode Press and hold down RANGE for 2 seconds the AUTO annunciator turns back on 6 AC DC Current Select and select Button a To select function DC or AC current b To select continuity measurements or Diode tests 7 Date Hold Button Press it once to hold the measured value in dark place when readi...

Page 6: ...black test lead on the negative side and the red lead on the positive side being measured 4 Apply power and read the Current value on LCD 10 4 4 Diode Tests WARNING Before taking any in circuit measurement remove power from the circuit being tested and discharge all capacitors in the circuit 1 Connect red test lead to the VΩ terminal and black test lead to the COM terminal 2 Set range switch to th...

Page 7: ... hazard or shock turn off multi meter and disconnect test leads before removing back cover 5 1 Battery Check Up Replacement 1 As battery power is not sufficient LCD will display Replacement of Two new batteries type AAA 1 5V is required 2 Set Range Switch to OFF position Use a screw drive to remove the rear cover Take out the battery and replace them with two new batteries of type AA 1 5V 3 Place ...

Page 8: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net Home page http www tes com tw Feb 2002 4 ...

Page 9: ......

Reviews: