Copyright Tes Drying Systems, 2014
35
On occasion the processor on the E-TES SD units will lock up. When this happens, the E-TES SD will not
function and the display will show only a line of rectangles or will remain blank when the power switch is
turned on. This problem can easily be corrected in the field by resetting the processor. Sometimes simply
clicking the Power Switch OFF and back ON quickly will unlock and reset the processor. If not, follow these
instructions:
E-TES SD machines have a small hole in the front face plate just above the USB port and below the indicator
light. With the E-TES SD unplugged and the Power Switch in the OFF position, poke a toothpick or paper
clip through the small hole to push the reset button behind the front faceplate. Hold the button for 2-3
seconds.
After resetting the processor, the E-TES SD Date & Time Clock must be reset.
Use the UP & DOWN buttons to move through the menu to the current date & time screen.
♦
Press
SELECT
to set the E-TES SD Date & Time Clock.
♦
HOUR will flash first. Use the
UP/DOWN
buttons to change the HOUR setting. When correct, press
SELECT
to move to MINUTES.
♦
Use the
UP/DOWN
buttons to change the MINUTES setting. When correct, press
SELECT
to move
to SECONDS & press SELECT again to move to the MONTH setting.
♦
Use the
UP/DOWN
buttons to change the MONTH setting. When correct, press
SELECT
to move to
DAY NUMBER. (The DAY NAME will change as you adjust the MONTH, DAY NUMBER & YEAR.)
♦
Use the
UP/DOWN
buttons to change the DAY NUMBER setting. When correct, press
SELECT
to
move to YEAR.
Use the
UP/DOWN
buttons to change the YEAR setting. When correct, press
SELECT
to save setting
and exit the date & time screen. Use the
UP/DOWN
buttons to move through the menu to check and reset
your activation or shutdown settings on Air Temperature, Surface Temperature, Moisture 1, Moisture 2,
Remote Setup & Air Flow Setup as needed.
Access hole used to reset the
microprocessor on the E-TES SD
E-TES SD 120 Resetting the Processor