ATTENTION! To avoid injuries and burns it is necessary to provide maximum reliable fastening of the tank 
to the wall.

ATTENTION! The wall at which the remote tank is installed shall support the weight of the tank fully filled 
in with water.

When water starts to boil cold water shall be added into the tank. Don't pour the water in tank up to the top 

because when water starts to boil it may spill over.

ATTENTION! It is prohibited to misuse the tank.

ATTENTION! It is prohibited to use defective tank having visual damages and (or) leakages.

ATTENTION! It is prohibited to use the tank under excessive pressure that differs from the atmospheric 
one.

ATTENTION! It is prohibited to touch the warmed up to high temperatures surfaces of the tank with bare 
hands or with other parts of body in order to avoid burns and damages.

«Termofor» company recommends to use «Battery-Fire» sauna stove along with tanks of «Termofor» 

trademark.

ATTENTION!

 

Before the stove firing up make sure that there is draft in the flue. Home draft testing is 

performed as follows set a lighted match to the open firebox door, if the flame is pulled into the firebox 
there is draft in the flue

.

ATTENTION!

 

Those who did not read the operating instructions must not use the stove in order to avoid 

personal injury

.  

Check the firebox and ash

 drawer b

efore every stove firing

, and if necessary, clean them 

of ashes and other 

items (unburnt firewood

, foreign objects that were in wood (nails)) remain

ing since

 the previous use.

Firewood should be put through the door on the grate. When firing

 

up put firewood loosely, pull out the ash 

drawer, and open the damper flap to provide intense fuel firing and access of air to the combustion zone

.

Do not top up the stove, it may

 cause 

a dangerous situation when opening the door

Do not leave the door 

open after firing

 up.

ATTENTION!

 

Do not place burning firewood close to the door. Failure to comply with this instruction may 

result in door deformation, glass damage

and room smoke

.

ATTENTION!

 

Do not fire the stove with the door open. This can lead to dangerous

 

stove operation 

conditions

room smoke

and a fire

 accident.

ATTENTION!

 

Forced air-feeding into the ash drawer

 

is strictly forbidden

.

To reduce the amount of harmful emissions

 you should first fire 

the upper portion of wood

 and during 

further 

operation add firewood in small portions.

 

It takes some time a stable draft to arise after the stove firing up. Therefore, light smoke is possible if you open

the door when the stove operates in raising temperature conditions. T

he first fuel portion

 burning 

is enough for the 

flue warming and draft effect

 to 

prevent smoke.

Later on

 the air supply, which affects the 

combustion intensity, can be controlled by opening or closing the ash 

drawer and damper flap

.

To put the next wood

 portion, 

fully open the damper flap and close the ash drawer, in a few seconds after that 

gradually open the door

While putting the next firewood

 portion, be careful not to put out the fire.

To terminate the stove operation

, you should wait until the fuel is completely burned, then clean the 

stove

 

of

 

ashes and close the door and the ash drawer.

ATTENTION!

 

Do not extinguish with water

.

7.8. Stove operation

Summary of Contents for Battery Fire 11

Page 1: ...Battery Fire USER MANUAL ...

Page 2: ...ication 2 Product line 3 Design features 4 Specifications 5 Stove structure 7 Marking and packaging 8 Proper use 9 Maintenance 10 Preventive maintenance 11 Warranty 12 Storage 13 Transportation 14 Disposal 15 Delivery package ...

Page 3: ...ners All models have two versions with an internal heat exchanger tank and without it Heat exchanger tank is intended to heat water for domestic use The stove version with an internal heat exchanger tank marked with the letter WT tank in its designation as follows Battery Fire 7WT Table 1 Battery Fire model line 3 DESIGN FEATURES All Battery Fire models have design features that distinguish them a...

Page 4: ...s sawdust briquettes for closed type heaters and pellets IMPORTANT The maximum capacity of heated space defined by the conditions for effective convection heat transfer and the walling overall heat transfer resistance standards according to SNiP 23 02 2003 construction norms and regulations or according to the technical standards of the country in which the stove is used Figure 2 Battery Fire 5WT ...

Page 5: ...odels Battery Fire 7 Battery Fire 7WT Heated space capacity max cu m 150 150 Nominal power kW 10 10 Overall dimensions WDH mm 370 680 760 370 680 760 Weight kg 52 54 Firebox door opening mm 150 300 150 300 Combustion chamber capacity l 47 45 Fuel maximum amount l 42 40 Firewood length max mm 420 400 Flue diameter mm 120 120 Flue recommended height m 5 5 Heat exchanger tank capacity l 1 3 Models Ba...

Page 6: ...esistant glass SCHOTT ROBAX 5 When firing primary air required for burning is supplied to the fuel through the ash drawer 8 door left ajar and cast iron grate 13 to provide supplemental firing and a powerful high temperature flame at the moment of ignition ATTENTION The stove is designed to operate only in smouldering conditions Never use the stove in open fire conditions open flame is permitted o...

Page 7: ...ess ATTENTION Cooking top is heated to a high temperature The stove external surface is coated with a heat resistant organosilicon enamel of KO 868 type ATTENTION The manufacturer reserves the right to change the stove design without impairing its consumer properties Fire gases are directed into the flue through the flue outlet of 120 mm diameter disposed at the rear of the stove There is a damper...

Page 8: ...d explosion safety in accordance with NPB ÍÏÁ 105 95 classification of premises and buildings of fire and explosion safety ATTENTION Don t use matters as fuel which aren t mentioned under point 4 ATTENTION Expressly prohibited using charcoal and coal briquettes as fuel ATTENTION Don t use alcohol containing means benzene kerosene and other highly inflammable matters for ignition Don t use a glossy...

Page 9: ...ut damage burnouts and cracks n the ash drawer moves freely and fits tightly to the body in the closed position n the fine adjustment valve flap rotates freely and tightly covers the opening in the closed position n the heat exchanger tank is sealed without cracks or leaks Place the stove on a specially prepared place for its operation Protect from fire constructions of premises n Walls or partiti...

Page 10: ...details concerning the procedure of the stove safe and proper installation Installation drawings are shown in Figure 6 The distance from the firebox door to the opposite wall should be not less than 1250 mm The distance between the stove top and unprotected ceiling should be not less than 1200 mm 1 Bonnet 2 Finish sandwich Termofor 3 Flue module insulated sandwich Termofor 4 Non combustible ceilin...

Page 11: ... from the outside of the stove makes the air move into the area of lower pressure into the area of fire box Thus the air intake into the fire chamber happens This constant air inflow is the draught The stove won t be operating effectively if there is no draught of the definite value The optimal draught for operation of stoves of Termofor trademark equals to 12 2 Pa Provided the excessive draught t...

Page 12: ...ible smoke generation The manufacturer recommends the use of Termofor modular light wall superalloy rust resisting steel stacks with diameter of 120 mm They are effective long life and require minimal effort for installation and operation Steel stack installation with upward outlet is shown in Figure 13 a When installing the stove with the stack backward outlet it is recommended that the stove sho...

Page 13: ...ments of SNIP 41 01 2003 construction norms and rules or in compliance with technical norms of the country where the stove will be used ATTENTION It is strictly prohibited to make dismountable the connections of the stove with the stove pipe or other structural elements of the room ATTENTION In case of fire in the stove pipe shut the dampers of air supply into the fire chamber leave the room and i...

Page 14: ...d connections by plumbing sealant or PTFE 4 band GOST24222 80 GOST national state standard ATTENTION Hot water tank is the unit of extra high hazard that is why it is necessary to exercise caution while being near it ATTENTION Termofor company is not responsible for improper fastening of the tank ATTENTION Avoid corrosive substances entering the hot water tank and water heating system ATTENTION It...

Page 15: ... should be put through the door on the grate When firing up put firewood loosely pull out the ash drawer and open the damper flap to provide intense fuel firing and access of air to the combustion zone Do not top up the stove it may cause a dangerous situation when opening the door Do not leave the door open after firing up ATTENTION Do not place burning firewood close to the door Failure to compl...

Page 16: ... prevent free convective stream ATTENTION Don t dry any things and objects on a partly cold surface of the stove ATTENTION Carbon monoxide generation may be deathful Carbon monoxide has neither smell nor colour and is generated during the combustion of wood coal oil gas and other combustion agents It is important to have good draught and reliable ventilation system so that combustion products were...

Page 17: ...e And if afterwards they ignite this creates extreme temperatures in the chimney stack and may lead to ignition of materials surrounding the pipe and cause fire ATTENTION Provided the creosote ignition in the stove pipe shut all air dampers of the stove leave the room and call the firemen ATTENTION The heating stove is a fire hazard source Open and close the door only by the handle Raked out ashes...

Page 18: ...eplace and stove glasses in accordance with the instruction It is prohibited to use the stove with damaged translucent screen In case of glass damages for its replacement it is necessary to install only high temperature ceramic glass with thickness of 4 mm and correct dimensions For correct replacement order see cl 9 Do not use instead of the glass the heat strengthened glass or thickened window g...

Page 19: ...has established that a defect is in 12 months from the date of transfer the Products to the Consumer 2 It has established that a defect is due to the fault of the company Termofor Warranty doesn t apply to the Products and also its units or elements which have been changed by the Consumer Warranty doesn t apply to elements of the Products which shall be substituted at the time of normal operation ...

Page 20: ...he time of end of operating life or breakdown of the stove in consequence of improper operation At the time of disconnect the stove and its elements from the flue shall protect eyes and anatomical airways from a dust and soot in the elements of the system which have arisen during the operation ATTENTION Dismantle the stove only after its full cooling The product does not contain in its composition...

Reviews: