ATTENTION! To avoid injuries and burns it is necessary to provide maximum reliable fastening of the tank
to the wall.
ATTENTION! The wall at which the remote tank is installed shall support the weight of the tank fully filled
in with water.
When water starts to boil cold water shall be added into the tank. Don't pour the water in tank up to the top
because when water starts to boil it may spill over.
ATTENTION! It is prohibited to misuse the tank.
ATTENTION! It is prohibited to use defective tank having visual damages and (or) leakages.
ATTENTION! It is prohibited to use the tank under excessive pressure that differs from the atmospheric
one.
ATTENTION! It is prohibited to touch the warmed up to high temperatures surfaces of the tank with bare
hands or with other parts of body in order to avoid burns and damages.
«Termofor» company recommends to use «Battery-Fire» sauna stove along with tanks of «Termofor»
trademark.
ATTENTION!
Before the stove firing up make sure that there is draft in the flue. Home draft testing is
performed as follows set a lighted match to the open firebox door, if the flame is pulled into the firebox
there is draft in the flue
.
ATTENTION!
Those who did not read the operating instructions must not use the stove in order to avoid
personal injury
.
Check the firebox and ash
drawer b
efore every stove firing
, and if necessary, clean them
of ashes and other
items (unburnt firewood
, foreign objects that were in wood (nails)) remain
ing since
the previous use.
Firewood should be put through the door on the grate. When firing
up put firewood loosely, pull out the ash
drawer, and open the damper flap to provide intense fuel firing and access of air to the combustion zone
.
Do not top up the stove, it may
cause
a dangerous situation when opening the door
.
Do not leave the door
open after firing
up.
ATTENTION!
Do not place burning firewood close to the door. Failure to comply with this instruction may
result in door deformation, glass damage
,
and room smoke
.
ATTENTION!
Do not fire the stove with the door open. This can lead to dangerous
stove operation
conditions
,
room smoke
,
and a fire
accident.
ATTENTION!
Forced air-feeding into the ash drawer
is strictly forbidden
.
To reduce the amount of harmful emissions
you should first fire
the upper portion of wood
and during
further
operation add firewood in small portions.
It takes some time a stable draft to arise after the stove firing up. Therefore, light smoke is possible if you open
the door when the stove operates in raising temperature conditions. T
he first fuel portion
burning
is enough for the
flue warming and draft effect
to
prevent smoke.
Later on
the air supply, which affects the
combustion intensity, can be controlled by opening or closing the ash
drawer and damper flap
.
To put the next wood
portion,
fully open the damper flap and close the ash drawer, in a few seconds after that
gradually open the door
.
While putting the next firewood
portion, be careful not to put out the fire.
To terminate the stove operation
, you should wait until the fuel is completely burned, then clean the
stove
of
ashes and close the door and the ash drawer.
ATTENTION!
Do not extinguish with water
.
7.8. Stove operation
Summary of Contents for Battery Fire 11
Page 1: ...Battery Fire USER MANUAL ...