7.4. Stove assembly
ATTENTION! All the stove assembly and stones setting into the stones section works shall be carried out
only after total cooling off of the stove.
ATTENTION! The stove is heavy. Make sure that you have the possibilities and equipment for its moving.
ATTENTION! It is prohibited to install the stove in the places where the stove will create obstacles for
people moving during evacuation.
ATTENTION! It is necessary to carry out the installation of smoke sensors and gas detectors in the rooms
where the stove is installed.
Place the stove
on a specially prepared
place
for its operation.
Make sure
that the
stove
is assembled and
installed
properly
.
If the installation instructions are not completely understood, or if
you have doubts on whether the stove is
properly installed consult an experienced expert
who knows all details
concerning the procedure of the stove safe
and proper installation
.
Installation drawings are shown in Figure 6
.
The distance from the firebox
door to the opposite wall should be
not less than 1250 mm. The distance between the
stove top and unprotected ceiling
should be not less than 1200
mm.
1 - Bonnet
2 - Finish sandwich
«
Termofor
»
3
–
Flue module insulated (sandwich)
«
Termofor
»
4 - Non-combustible
ceiling
5 - Ceiling making
6 - Start-sandwich
«
Termofor
»
7 - Walls of combustible material
8
–
Stove base of fire-resistant material
9
–
Pre-fireb
ox sheet
10 - Metal sheet on asbestos board to protect the walls of
combustible materials
1
2
0
0
m
in
7
0
Figure 12:
«
Battery-Fire
7» installation i
n the room decorated with
combustible materials (wood)
on the base of
non-combustible material
;
5
0
0
380
À
3
8
0
700
5
0
0
1
5
3
7
8
10
4
2
5
0
À
9
6
2
a metal plate on a heat-insulation material (an
asbestos paper with thickness 10 mm)
wood (inflammable material)
a thermal insulation of a nonflammable material
(haydite/dross/ basalt wool)
bricks and so on (a nonflammable material)