In case of installation of thick-walled metal, ceramic, asbestos-cement or other chimney stack of greater weight
it is necessary to unload the stove from its weight.
ATTENTION! The manufacturer shall not be responsible for the influence of external factors on the
reduction of natural draught in the stove pipe.
ATTENTION! It is prohibited to use chimney stacks with galvanic coating.
ATTENTION! Do not use pipes from different manufacturers in the stove pipe.
ATTENTION! To avoid the smoke blowing into the heated room all the places of chimney stack units
connection against each other and the stove it is necessary to compact with high-temperature sealant (not
less than 1000°Ñ) providing the air-tightness of the pipe junctions.
ATTENTION! The junction of stove pipe units in overlaps and fire block is prohibited.
ATTENTION! The section of chimney stack located in the zone of sub-zero temperatures shall be obligatory
heat insulated by non-combustible material, withstanding temperatures not less than +400 °Ñ.
The ideal solution for chimney stack – is the installation of ready-made pipe units with heat insulation of
«
sandwich
»
type of «Termofor» trademark.
In case of connection of the stove to fixed built-in stove pipe or in other cases it is not recommended to deflect
the axis of chimney stack from the vertical line for more than 45°.
ATTENTION! sauna stove and chimney stack assembly shall be carried out by qualified workers from the
specialized construction and installation company in compliance with the requirements of SNIP 41-01-
2003 (construction norms and rules) or in compliance with technical norms of the country where the
stove will be used.
ATTENTION! It is strictly prohibited to make dismountable the connections of the stove with the stove pipe
or other structural elements of the room.
ATTENTION! In case of fire in the stove pipe shut the dampers of air supply into the fire chamber, leave the
room and immediately call the firemen.
In case of fire in the stove pipe it is necessary to have a clear scheme of actions that shall be elaborated by
consulting the specialist. After the fire in the stove pipe will die down, the stove pipe shall be cleaned and checked
for the destructions. Make sure that there are no flammables around the stove pipe.
The interior wood air heating stove
«
Battery-Fire
»
of
«WT»
version
includes the heat
exchanger tank
to heat
water for domestic use
ATTENTION! Don't connect a heating system to a heat exchange unit.
The general scheme of water heating system installation is shown in Figure 15
.
The water heating components
,
with the exception of an internal
heat exchanger tank
,
are not supplied (optional).
A water heating system consists of:
n
A heat exchange unit (3) with two fitting adapter;
n
Connective pipes (pipeline) (7);
n
An outboard tank (5) for hot water with two fitting adapters for connecting to a heat transfer system and
one fitting adapter for installation of a tap of hot water distribution;
n
A tap for hot water (6), a tap for water drain from a system (8).
At the time of installation of a water heating system, a bottom of an outboard tank for hot water shall be over
of a level of a top fitting adapter of a heat transfer device no less than 30 cm.
7.6. Water heating system installation