INITIAL OPERATION OF THE DEVICE

•  Ensure that the installation connections of the device are made 

correctly.

•  It should be sure that the air of the device and the installation 

system (radiator or underfloor heating) is taken and the pressure 

on the manometer should be 1.5 bar.

•  Ensure that the electrical connection of the device is made cor-

rectly, that the cable is drawn in the appropriate section, that the 

leakage current relay is installed in the appropriate amperes, and 

that the ground line is connected. These procedures must be 

done by authorized electricians.

•  Ensure that the voltage supplied to the device is appropriate, low 

or not high.

•  The radiator temperature and external hot water tank temperature 

should be set to 40 °C during the first operation of the device. 

When it is operated for a while and made sure there is no air in it, 

the consumer can adjust the temperature he wants.

•  The device must be activated by our technical services in order 

to operate efficiently and smoothly and to be valid under warranty 

conditions.

Warning 

The circulation pump can be locked due to calcareous water 

and corrosion in devices that have not been run for 3 months 

or more after water pressing. The pump should be given way.

For the devices in this case, contact the Authorized Service 

must be made before starting.

Summary of Contents for GALAXI SMART Series

Page 1: ...heating systems GALAXI SMART SERIES ELECTRIC COMBI BOILER User Manual and Warranty Certificate Certificate No AQ TR 2165 TS EN ISO 9001 2000 ...

Page 2: ...boilerandfloorheatingveryclosely Weaimtomakeourcustomersbenefitfromthelatesttechnologybyapplyingtechnologi caldevelopmentstoourproducts Warmingandproducinghotwaterwillnolongerbeaproblem wewillcontinuetopro ducethebestproductsforyou Thankyouforchoosingus Hopetouseyourproductongooddays BestRegards Always read the operating instructions before using the product heating systems ...

Page 3: ... Connection 6 Electrical Connection Of The Device 7 Flooding The Device 9 Initial Operation Of The Device 10 Using The Control Panel Of The Device 11 Device Error Information 15 ElectricalConnectionDiagramandPanelOutputInformation 16 Safety Precautions Of The Device 17 Periodic Maintenance Of The Device 17 Rules That Must Be Followed 18 CONTENTS ...

Page 4: ...t 3 Manometer 4 Expansion Tank 5 Reset Safety Thermostat 6 Power Distribution Board 7 Boiler Body 8 Boiler Heat Probe 9 Resistances 10 Automatic Air Evacuation 11 Circulation Pump 12 3 Bar Safety Valve 13 Filling Valve PARTS OF ELECTRIC BOILER Cold Water Inlet 1 2 Heating Return 3 4 Heating Going 3 4 ...

Page 5: ... with the device in the event of a technical failure or maintenance a gap must be left around the device in the following dimensions If the installation of the device has not been carried out according to the standards specified in the user guide and the dimensions specified below are not left around the device the Authorized Service will charge a fee regardless of warranty status Warning It is th...

Page 6: ... The easy to open and close cover is designed by Termoakım for easy intervention in the device To open the cover the bottom right and top screws are removed as shown in the picture below and the cover opens to the left side Easy to opencoveropeningshapeanddirection ...

Page 7: ...s and records are complete as shown in Fig 1 The air intake valve outlet under the device is used to take the air out of the device When air is being taken from here the air intake valve should be connected to any outlet for the future of water Fig 2 The drain outlet under the device should be connected to any outlet because it will automatically open and drain itself out in 3 bars when too much w...

Page 8: ... must exit the device and be connected to the external hot water tank As this feature is optional the three way valve cable and heat sensor are not supplied with the device If the device is to be used in external hot water tank mode external hot water tank mode is switched on from the menu of the device The device can be used in this mode External hot water tank heat sensor and three way valve cab...

Page 9: ... be pulled into the device must comply with TSE Turkish Standards Institute norms Electrical connections of the device should only be made by au thorized electricians The cable to be drawn to the device must be pulled from the main network panel The cable to be pulled must be in one piece with no attachment The cable section to be cut into the device the leakage current relay ampere and the ground...

Page 10: ...tion From the R S T phase ends at the input terminal input is made to R phase and bridged to S and T phas es 3 phases are bridged together Neutral and ground line are connect ed Is shown in the figure Triphase Connection Input to R S T phase ends at the input terminal Neutral and ground line are connected Is shown in the figure ...

Page 11: ...es from the air intake valve the air intake valve is closed The pressure is brought to 1 5 bar and the water pressing process is completed When the water pressure of the device falls below 1 bar it causes a low pressure error In this case the filling valve is opened and the pressure is brought to 1 5 bar If this situa tion is constantly happening there is a possibility of leakage in the installati...

Page 12: ...horized electricians Ensure that the voltage supplied to the device is appropriate low or not high The radiator temperature and external hot water tank temperature should be set to 40 C during the first operation of the device When it is operated for a while and made sure there is no air in it the consumer can adjust the temperature he wants The device must be activated by our technical services i...

Page 13: ... com PUMP POSITION EXTERNAL HOT WATER TANK TEMPERATURE CLOCK DEVICE RATING EXTERNAL HOT WATER TANK MODE KEY HEATING MODE KEY INPUT CONFIRMATION KEY ON OFF KEY MENU INPUT KEY EXIT KEY DOWN ARROW DECREASE KEY TIME CLOCK ACTIVATION KEY UP ARROW INCREASE KEY RADIATOR TEMPERATURE DEVICE MODE POWER LEVEL ...

Page 14: ...k Mode 9 Service Setting The Set Temperature Of The Device Radiator temperature adjustment Press the menu button scroll to the radiator temperature setting press enter press the arrow keys to the desired degree and press enter the degree will be stored Exit with the Esc key Repeat this process while adjusting again External hot water tank temperature adjustment Press the menu key press the arrow k...

Page 15: ...press enter to position the square full if you do not want it to work with the arrow key past the empty square to leave the device will not work on the day with the empty square Exit with the Esc key The timer setting is now in memory To run in the timer position press the timer key in the panel and the device switches to my timer position In the upper left corner of the screen the mode section ex...

Page 16: ...vice has seen high temperatures 8 Safety Thermostat Counts how many times the device sees a safety thermostat 9 Boiler Sensor Counts the boiler sensor failure of the device 10 External hot water tank Sensor Counts the external hot water tank sensor failure of the device 11 Pump Counts the working time of the circulation pump 12 Power outage Counts how many times the device has suffered a pow er fa...

Page 17: ...remove the cover of the reset thermostat After waiting for a while press the reset button If the rating is still high the button will not fit in When you press it after the degree has dropped it will snap into place with the click sound The device is reseted with this way When the device is turned off and turned on the error information on the display will be erased You can now use your device in ...

Page 18: ... 3 1 SAFETY THERMOSTAT 2 RELAY CARD 3 INPUT TERMINAL 4 SAFETY THERMOSTAT SOCKET 5 3 WAY VALVE CABLE SOCKET T1 6 CIRCULATION PUMP SOCKET T2 7 CONTROL PANEL 8 ROOM THERMOSTAT SOCKET T3 9 PRESSURE SWITCH WATER KIT T4 10 EXTERNAL HOT WATER TANK HEAT PROBE 11 BOILER SENSOR 12 DATA CABLE 13 GROUND LINE CONNECTION ...

Page 19: ...INTENANCE OF THE DEVICE The following maintenance must be performed by the Authorized Service every year regardless of whether the device is guaranteed or not Water circuit is checked whether there is any leakage if any seal ing is provided Whether the resistances are working is controlled by measuring instrument Check the seals of the resistances Replaced if necessary The safety parts in the devi...

Reviews: