FLOODING THE DEVICE
The air intake valve under the device opens. The automatic air drain
located through the circulation pump is loosened. The filling valve is
opened in half and slowly flooded. Water will come from the air in-
take valve at the end of the air. Until this process, the flooding contin-
ues. When water comes from the air intake valve, the air intake valve
is closed. The pressure is brought to 1.5 bar and the water pressing
process is completed. When the water pressure of the device falls
below 1 bar, it causes a low pressure error. In this case, the filling
valve is opened and the pressure is brought to 1,5 bar. If this situa-
tion is constantly happening, there is a possibility of leakage in the
installation. This may also damage the device. Contact Authorized
Service.
Air Intake
Valve
Manometer
Water Pressure Valve
3 Bar
Safety
Valve
Outlet