4-24
GTH-1256
Part No. 1272856
September 2016
Section 4 • Fault Codes
110
0
High coolant temperature; warning threshold exceeded
110
0
High coolant temperature; shut off threshold exceeded
110
3
Sensor error coolant temperature; signal range check high
110
4
Sensor error coolant temperature; signal range check low
111
1
Coolant level too low
132
11
Air
fl
ow sensor load correction factor exceeding the maximum drift limit; plausibility error
132
11
Air
fl
ow sensor load correction factor exceeding drift limit; plausibility error
132
11
Air
fl
ow sensor low idle correction factor exceeding the maximum drift limit
132
11
Air
fl
ow sensor load correction factor exceeding the maximum drift limit
157
3
Sesnor error rail pressure; signal range check high
157
4
Sensor error rail pressure; signal range check low
164
2
Rail pressure safety function is not executed correctly
168
0
Physikal range check high for battery voltage
168
1
Physikal range check low for battery voltage
168
2
High battery voltage; warning threshold exceeded
168
2
Low battery voltage; warning threshold exceeded
168
3
Sensor error battery voltage; signal range check high
168
4
Sensor error battery voltage; signal range check low
171
3
Sensor error environment temperature; signal range check high
171
4
Sensor error environment temperature; signal range check low
172
0
Physical range check high for intake air temperature
172
1
Physical range check low for intake air temperature
172
2
Sensor ambient air temperature; plausibility error
172
2
Intake air sensor; plausibility error
172
3
Sensor error intake air; signal range check high
172
4
Sensor error intake air sensor; signal range check low
174
0
High low fuel temperature; warning threshold exceeded
174
0
High Low fuel temperature; shut off threshold exceeded
175
0
Physical range check high for oil temperature
175
0
High oil temperature; warning threshold exceeded
175
0
High oil temperature; shut off threshold exceeded
175
0
High customer oil temperature; warning threshold exceeded
175
0
High customer oil temperature; shut off threshold exceeded
175
1
Physical range check low for oil temperature
175
2
Sensor oil temperature; plausibility error
175
2
Sensor oil temperature; plausibility error oil temperature too high
FAULT CODES