![Terbly GL2P User Manual Download Page 36](http://html.mh-extra.com/html/terbly/gl2p/gl2p_user-manual_1088590036.webp)
GL2P User Manual XM1460-V1.0-NR
35
defective (or its driving IC on the main PCB). The CTO - movement is not located in the default
position after the reset.
ROT_GOBO wheel Er
(ROT_GOBO wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The ROT_GOBO - movement is not located in the
default position after the reset.
ROT_GOBO_R wheel Er
(ROT_GOBO_R wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The ROT_GOBO_R - movement is not located in
the default position after the reset.
FIX_GOBO wheel Er
(FIX_GOBO wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The FIX_GOBO - movement is not located in the
default position after the reset.
IRIS wheel Er
(IRIS wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The IRIS - movement is not located in the default
position after the reset.
PRISM wheel Er
(PRISM wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The PRISM - movement is not located in the
default position after the reset.
PRISM_R wheel Er
(PRISM_R wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The PRISM - movement is not located in the
default position after the reset.
BLADE wheel Er
(4_BLADE wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is
defective (or its driving IC on the main PCB). The BLADE - movement is not located in the
default position after the reset.
BLADE_ROT wheel Er
(4_BLADE_ROT wheel_ error) This message will appear after the reset of the fixture if the
head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper
motor is defective (or its driving IC on the main PCB). The BLADE_ROT - movement is not
located in the default position after the reset.