background image

 

MI-TZG2-XX                                                                                  Rev_25/09/2015

 

 

SPÉCIFICATION

 

TECHNIQUE 

 

C

ONNEXION

 

2

1/2"

 FEMELLE 

NPT 

D

ÉBIT

 

V

ALVE THERMOSTATIQUE

 

30

 

L/

MIN 

[7,9

 GPM

]

 

@

 

60

 PSI

 

T

ÊTE DE PLUIE 

SSTS-08-S  7,9

 

L/

MIN 

[2,1

 GPM

]

 

@

 

60

 PSI

 

D

OUCHETTE 

HS-205 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

3

J

ET DE CORPS

 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

B

EC DÉVIATEUR

 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

É

QUIPEMENT

  E

MBOUTS DE SILICONE ANTI

-

CALCAIRE 

 

3

V

ALVE D

ARRÊT EN CÉRAMIQUE

 

B

OYAU 

SSHE-175 

A

SSEMBLÉ AVEC BOYAUX EN ACIER INOXYDABLE

 

I

NFORMATION

  P

RESSION MINIMALE

 

35

 PSI

 

P

RESSION MAXIMALE

 

80

 PSI

 

A

RRÊT DE SÉCURITÉ

 

100,4°F

 

[38°C] 

C

ONNEXION

 

½’’

 

F

EMELLE

 

B

OYAU DE RACCORDEMENT

  60

CM 

(24’’)

 À HAUT DÉBIT

 

G

ARANTIE À VIE LIMITÉE

 

 

 

 

MI-TZG2-XX                                                                                  Rev_25/09/2015

 

 

TECHNICAL

 

INFORMATION 

 

C

ONNECTION

  2

1/2"

 FEMALE 

NPT 

F

LOW RATE

 

T

HERMOSTATIC VALVE

 

30

 

L/

MIN 

[7,9

 GPM

]

 

@

 

60

 PSI

 

S

HOWER HEAD 

SSTS-08-S  7,9

 

L/

MIN 

[2,1

 GPM

]

 

@

 

60

 PSI

 

H

AND SHOWER 

HS-205 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

3

B

ODY JETS

 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

D

IVERTER SPOUT

 

9,5

 

L/

MIN 

[2,5

 GPM

]

 

@

 

60

 PSI

 

H

ARDWARE

 

A

NTI

-

SCALE SILICON NOZZLES 

 

3

C

ERAMIC SHUT

-

OFF VALVE

 

H

OSE 

SSHE-175 

A

SSEMBLED WITH STAINLESS STEEL BRAIDED HOSES

 

I

NFORMATION

  M

INIMAL PRESSURE

 

35

 PSI

 

M

AXIMAL PRESSURE

 

80

 PSI

 

S

AFETY STOP

 

100,4°F

 

[38°C] 

C

ONNECTION

 

½’’

 

F

EMALE

 

C

ONNECTING HOSES

 

60

CM 

(24’’),

 

HI

 FLOW

 

L

IMITED LIFETIME WARRANTY

 

 

 

Summary of Contents for TZG2 Series

Page 1: ...MI TZG2 XX Rev_25 09 2015 2 INSTALLATION MANUAL USER GUIDE MANUEL D INSTALLATION GUIDE DU PROPRIÉTAIRE TZG2 XX ...

Page 2: ...LÈME SUITE À UNE INSTALLATION ADÉQUATE N HÉSITEZ PAS À CONTACTER VOTRE REVENDEUR ACCRÉDITÉ OU LE SERVICE TECHNIQUE DE TËNZO RESPECTEZ TOUJOURS LE CODE DE PLOMBERIE AINSI QUE LE CODE DU BATIMENT EN VIGEUR MI TZG2 XX Rev_25 09 2015 4 THANK YOU FOR CHOOSING TËNZO TAKE THE TIME TO CAREFULLY READ EACH STEP OF THE INSTALLATION PROCEDURE BEFORE YOU BEGIN AND THAT YOU HAVE ALL THE TOOLS NECESSARY ON HAND ...

Page 3: ...DEUR AUTORISÉ OU DIRECTEMENT AVEC TËNZO À support tenzo ca POUR CONSULTER LA GARANTIE COMPLÈTE VEUILLEZ CONSULTER NOTRE SITE INTERNET AU www tenzo ca MI TZG2 XX Rev_25 09 2015 6 LIMITED LIFETIME WARRANTY TËNZO PRODUCTS ARE COVERED BY A FULL LIFETIME WARRANTY AGAINST MANUFACTURING DEFECTS ALL TRACES OF ABUSE IMPACT USAGE OTHER THAN RESIDENTIAL WILL CANCEL THE WARRANTY ANY MODIFICATION BROUGHT TO TH...

Page 4: ...ARRÊT DE SÉCURITÉ 100 4 F 38 C CONNEXION FEMELLE BOYAU DE RACCORDEMENT 60CM 24 À HAUT DÉBIT GARANTIE À VIE LIMITÉE MI TZG2 XX Rev_25 09 2015 8 TECHNICAL INFORMATION CONNECTION 2X 1 2 FEMALE NPT FLOW RATE THERMOSTATIC VALVE 30 L MIN 7 9 GPM 60 PSI SHOWER HEAD SSTS 08 S 7 9 L MIN 2 1 GPM 60 PSI HAND SHOWER HS 205 9 5 L MIN 2 5 GPM 60 PSI 3X BODY JETS 9 5 L MIN 2 5 GPM 60 PSI DIVERTER SPOUT 9 5 L MIN...

Page 5: ... TECHNICAL SERVICE OR YOUR RETAILER IF YOUR OUTLETS ARE AT A DIFFERENT HEIGHT TO ENSURE THAT INSTALLATION OF THE PRODUCT IS POSSIBLE ÉTAPE 1 A L INSTALLATION DE LA COLONNE DE DOUCHE À 25 DU SOL EST UNE HAUTEUR STANDARD POUR UNE PERSONNE MESURANT 5 8 LA HAUTEUR DE LA COLONNE DE DOUCHE EST DÉTERMINÉE PAR LES JETS DE CORPS POUR UNE INSTALLATION ADÉQUATE LE JET DE CORPS DU HAUT DOIT ÊTRE POSITIONNÉ À ...

Page 6: ...E PÉNÈTRE PAS LE MUR B LORSQUE LES MAMELONS SONT FIXÉS DRAINER LES CONDUITS D EAU CETTE ÉTAPE SERT À S ASSURER QU AUCUN DÉBRIS POUVANT AFFECTER LA PERFORMANCE DE LA COLONNE DE DOUCHE NE SE TROUVE DANS LES TUYAUX MI TZG2 XX Rev_25 09 2015 12 STEP 3 A DRILL FOUR HOLES IN THE WALL AT THE REQUIRED HEIGHT FOR EACH SHOWER COLUMN SUPPORT AND INSERT THE WALL ANCHORS PROVIDED IN THE ASSEMBLY KIT B PLACE TH...

Page 7: ...LE TOUT B RACCORDER LE BOYAU D ALIMENTATION DE LA TÊTE DE PLUIE AU BRAS DE DOUCHE ASSUREZ VOUS QUE LE JOINT D ÉTANCHÉITÉ SOIT BIEN EN PLACE C VISSER LA TÊTE DE PLUIE SUR LE BRAS DE DOUCHE MI TZG2 XX Rev_25 09 2015 14 STEP 5 A ASSEMBLE THE SHOWER COLUMN CONNECTING HOSES TO THE WATER OUTLETS NIPPLES ON THE WALL ENSURE THAT THE GASKETS ARE CORRECTLY POSITIONED TIGHTEN BOTH CONNECTORS USING A WRENCH B...

Page 8: ...HE PRESSURE SCREW UNDER THE HOLDER ÉTAPE 6 A VISSER LA FIXATION DE LAITON À LA HAUTEUR DÉSIRÉE À L AIDE DES DEUX VIS FOURNIES DANS LA TROUSSE D ASSEMBLAGE PLACER LE SUPPORT DE DOUCHETTE SUR LA PARTIE DE LAITON ET SERRER FERMEMENT LA VIS SOUS LE SUPPORT MI TZG2 XX Rev_25 09 2015 16 STEP 7 A FIX THE HOSE TO THE HAND SHOWER AND TO THE SPOUT ÉTAPE 7 A RATTACHER LE BOYAU À LA DOUCHETTE AINSI QU AU BEC ...

Page 9: ...UN AUTRES LINGES PUISQUE CEUX CI POURRAIENT DÉTÉRIORER LE FINI DU PRODUIT SI VOUS DÉSIREZ UTILISER UN PRODUIT NETTOYANT ET QUE VOUS N ÊTES PAS CERTAIN DE SON EFFICACITÉ APPLIQUEZ CELUI CI SUR UN LINGE HUMIDE ET ESSAYEZ LE SUR UN ENDROIT PEU APPARENT POUR TOUTE QUESTION SUR NOS PRODUITS OU SI VOUS RENCONTREZ UN PROBLÈME N HÉSITEZ PAS À NOUS CONTACTER IL NOUS FERA UN PLAISIR DE VOUS AIDER MERCI BEAU...

Reviews: