background image

 

 

                                                                                                               Rev_02-2018

 

11 

STEP

 

#1 

A

 

~

 

T

EMPORARILY  SCREW  THE  CASING  TO  THE  INSIDE  OF  YOUR  PARTITION  ON  THE  STUDS

.

 

L

EAVE 

APPROXIMATELY 

1"

 

(2.5

 CM

)

 OUTSIDE

.

 

T

HIS SECTION WILL BE USED TO FILL THE THICKNESS OF THE WALL 

(

WALL

,

 GLUE AND TILES

). 

B

 

~

 

C

ONNECT  THE  SUPPLIES  OF  HOT  AND  COLD  WATER  PIPES  TO  THE  CASING

,

  ENSURING  NOT  TO 

REVERSE  THEM

.

 

T

HEN  CONNECT  THE  EXTERNAL  COMPONENT  TO  THE  TEMPERED  WATER  OUTLET 

(

SHOWER HEAD

,

 BODY JET OR OTHERS

).

 

B

EFORE CLOSING THE WALL

,

 CONNECT THE VALVE SYSTEM AND 

COMPLETE A WATER PRESSURE TEST

ÉTAPE

 

#1

 

A

 

~

 

V

ISSER TEMPORAIREMENT LE BOITIER À L

'

INTÉRIEUR DE VOTRE CLOISON SUR LES COLOMBAGES

.

 

L

AISSER DÉPASSER CELUI

-

CI D

'

ENVIRON 

1’’

 

(2.5

CM

)

 À L

'

EXTÉRIEUR

.

 

C

ETTE PARTIE SERVIRA À COMBLER 

L

'

ÉPAISSEUR DU MUR 

(

MUR

,

 COLLE

,

 TUILES

). 

B

 

~

 

C

ONNECTER  LES  TUYAUX  D

'

ALIMENTATION  D

'

EAU  CHAUDE  ET  FROIDE  SUR  LE  CAISSON  EN 

S

'

ASSURANT DE NE PAS INVERSER CEUX

-

CI

.

 

R

ACCORDER LA SORTIE D

'

EAU TEMPÉRÉE À LA COMPOSANTE 

EXTERNE 

(

TÊTE  DE  PLUIE

,

  JETS  DE  CORPS  OU  AUTRES

).

 

A

VANT  DE  FERMER  LE  MUR

,

  CONNECTER  LE 

SYSTÈME DE VALVE ET PROCÉDER À UN TEST DE PRESSION D

'

EAU AVANT DE TERMINER LE MUR

 

 

 

 

 

                                                                                                               Rev_02-2018

 

12 

STEP

 

#2 

A

 

~

 

L

EAVE A GAP OF 

1/8''

 BETWEEN THE TILES AND THE CASING TO APPLY A PROPER SILICONE JOINT

.

 

 

B

 

~

 

O

NCE THE WALL IS CLOSED AND THE TILES ARE INSTALLED

,

 MAKE SURE THAT THE CASING DOES NOT 

EXCEED THE FINISHING

.

 

I

F REPOSITIONING OF THE CASING IS NEEDED

,

 REMOVE THE SCREWS AFFIXED IN 

S

TEP 

#1

 AND MAKE THE NECESSARY ADJUSTMENTS

C

 

~

 

I

T  IS  NECESSARY  TO  MAKE  A  SILICONE  JOINT  BETWEEN  THE  CASING  AND  TILES

.

 

D

O  NOT  USE 

CERAMIC GROUT

,

 ONLY SILICONE WILL ENSURE A MAXIMUM TIGHTNESS AGAINST WATER LEAKAGE

D

 

~

 

O

NCE YOUR WALL IS FINISHED

,

 IT IS NECESSARY TO DRAIN THE HOT AND COLD WATER LINES

ÉTAPE

 

#2 

A

 

~

 

L

AISSER UN ESPACE DE MINIMUM 

1/8''

 ENTRE LA BOITE MÉTALLIQUE ET LES TUILES DE 

CÉRAMIQUE

.

 

 

B

 

~

 

U

NE FOIS VOTRE MUR FERMÉ ET VOS TUILES POSÉES

,

 ASSUREZ

-

VOUS QUE LE BOITIER MÉTALLIQUE 

NE  DÉPASSE  EN  AUCUN  CAS  LE  MUR  FINI

.

 

S

I  VOUS  DEVEZ  MODIFIER  LA  POSITION  DE  LA  BOITE 

MÉTALLIQUE

,

 RETIRER LES VIS APPOSÉES À L

'

ÉTAPE 

#1

 ET FAITES L

'

AJUSTEMENT NÉCESSAIRE

C

 

~

 

I

L EST NÉCESSAIRE DE FAIRE UN JOINT DE SILICONE ENTRE LA BOITE MÉTALLIQUE ET LES TUILES

.

 

N

PAS UTILISER DE COULIS À CÉRAMIQUE

,

 SEULEMENT LE SILICONE ASSURERA UNE ÉTANCHÉITÉ MAXIMALE 

CONTRE LES FUITES

D

 

~

 

U

NE FOIS  VOTRE  MUR  ÉTANCHE

,

  IL  EST  IMPORTANT  DE  DRAINER  LES  LIGNES  D

EAU  CHAUDE  ET 

FROIDE

 

 

Summary of Contents for FL3VD-HC-XX

Page 1: ...Rev_02 2018 2 INSTALLATION MANUAL USER GUIDE MANUEL D INSTALLATION GUIDE DU PROPRIÉTAIRE Models Modèles ...

Page 2: ...O DAMAGES IF YOU FIND ANY DEFAULT WHATSOEVER IMMEDIATELY CONTACT YOUR ACCREDITED DEALER PLEASE LEAVE THE PRODUCT IN ITS ORIGINAL PACKAGING UNTIL READY TO INSTALL NO PRODUCT WILL BE ACCEPTED IF IT IS NOT IN THE ORIGINAL PACKAGING WE STRONGLY ADVISE YOU TO CONTACT A COMPETENT AND LICENSED INDIVIDUAL FOR THE INSTALLATION IN THE CASE THAT YOU WERE TO PERCEIVE ANY ANOMALY ON THE PRODUCT AFTER THE INSTA...

Page 3: ...TED LIFETIME WARRANTY AGAINST MANUFACTURING DEFECTS ALL TRACES OF ABUSE IMPACT OR USAGE OTHER THAN RESIDENTIAL WILL CANCEL THE WARRANTY ANY MODIFICATION BROUGHT TO THE LIMITED LIFETIME PRODUCT OR ANY IMPROPER INSTALLATION ACCORDING TO THE GUIDE WILL ALSO NOT BE COVERED BY THE WARRANTY IN EACH CASE TËNZO WILL REPAIR EXCHANGE OR MAKE A PROPER ADJUSTMENT TO HONOR ITS WARRANTY THE WARRANTY PERIOD FOR ...

Page 4: ...PSI 5 5 BAR Rev_02 2018 8 MAINTENANCE CLEANING YOUR TËNZO PRODUCT IS MANUFACTURED WITH HIGH QUALITY MATERIALS AND REQUIRES NO PARTICULAR MAINTENANCE HOWEVER A WEEKLY MAINTENANCE WITH A NON ABRASIVE SOFT SOAP FREE OF BLEACH AMMONIAC OR CITRUS BASED IS RECOMMENDED TO CLEAN STAINS CAUSED BY RESIDUAL SOAP OR MINERALS CONTAINED IN WATER A SOLUTION OF WATER AND VINEGAR 50 50 IS RECOMMENDED FOR THE MAINT...

Page 5: ...Rev_02 2018 9 SIZE AND HEIGHT OF INSTALLATION DIMENSION ET HAUTEUR D INSTALLATION Rev_02 2018 10 ...

Page 6: ...NER LE MUR Rev_02 2018 12 STEP 2 A LEAVE A GAP OF 1 8 BETWEEN THE TILES AND THE CASING TO APPLY A PROPER SILICONE JOINT B ONCE THE WALL IS CLOSED AND THE TILES ARE INSTALLED MAKE SURE THAT THE CASING DOES NOT EXCEED THE FINISHING IF REPOSITIONING OF THE CASING IS NEEDED REMOVE THE SCREWS AFFIXED IN STEP 1 AND MAKE THE NECESSARY ADJUSTMENTS C IT IS NECESSARY TO MAKE A SILICONE JOINT BETWEEN THE CAS...

Page 7: ... RACCORDEMENTS BIEN CONNECTÉS FAITE QUELQUES TESTS POUR VOUS ASSURER QU IL N Y AIT AUCUNE FUITE Rev_02 2018 14 STEP 4 A A SILICONE JOINT ON THE TOP AND THE SIDES OF THE CASING IS NECESSARY LEAVE THE BOTTOM FREE OF SILICONE TO ALLOW DRAINAGE IN CASE OF LEAKAGE B SLIDE THE PLATE INSIDE OF THE CASING AND FIRMLY PRESS AGAINST IT TO BOND THE SILICONE TO THE PLATE ÉTAPE 4 A UN JOINT DE SILICONE DE CHAQU...

Page 8: ...a tu re Rev_02 2018 16 DÉPANNAGE Alimentation des conduits d eau froide et chaude sont inversé Interchanger les boyaux d alimentation d eau 1 Boyau d alimentation coincé à l arrière Assurez vous que les boyaux d alimentation sont bien positionnés 2 Pression d eau inférieur à 35psi V alve thermostatique A Alimentation d eau par aqueduc ville Aucune solution possible B Alimentation d eau par puis Au...

Page 9: ...___________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ _...