PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
1
Move the machine to the tank draining area, and empty the solution tank and the dirty water tank.
2
Move the water delivery control to zero
3
Move the machine onto flat and dry flooring.
4
Press the emergency switch.
5
Remove the brush motor cover, unscrewing the four screws
A
on the sides.
6
Lower the head to simplify the dismantling operations.
7
Disconnect the cables
B
on the motor and the thermal cables
C
.
A1.3 Replacing the brush motor
Dismantling
Fig. 13
A
A
CHEM
Ͳ
DOSE
CONNECTOR
B
C
Fig. 14
8 of 73