PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
Check the brush motor fuse E paragraph D 5.1.
2
2
1
E2.1.1 The machine won’t start
E2.1 Troubleshooting
If there is no continuity replace the key contact.
Recharge the batteries.
Check battery voltage (B, BT).
4
Otherwise go to point 2
5
Check continuity of the brush motor protector.
E2.1.2 The brush doesn’t rotate
3
1
Check whether the display on the instrument
panel shows error code MOS.
If working correctly go to point 5.
Otherwise replace the main contactor.
Check the main contactor, see paragraph D 5.1,
D 6.1.
Check the continuity of the wiring.
Otherwise replace the protector or the motor.
If intact, go to point E 1.3.4
6
7
Check that squeegee the is clean and intact
8
Check continuity of the wires.
9
E2.1.3 No suction on the machine
If the hose is dirty or damaged, clean it or replace it
Replace the instrument panel board, see
paragraph C4.2, D6.1, D8.1.
Otherwise go to point 2
If everything is OK, go to point 3.
Otherwise replace the blades.
10
5
Check operation of the brush contactor, see
chapter D5.
Check the brush actuator, refer to the wiring
diagram.
1
2
Replace the brush motor.
Check the brush motor.
If the motor is intact go to point 10.
If there is continuity go to point 9.
3
Replace the squeegee.
If the squeegee is clean and intact, go to point 4.
Check that the suction hose is clean and intact B
3.2, B 3.4.
4
Otherwise restore continuity.
Otherwise replace it.
Check the lid gasket, see paragraph B 5.1.
4
Check that the squeegee blades are clean and
intact.
If shown, check that the contactor contact has not
remained closed see D5.
Otherwise adjust it or replace it.
If OK go to point 3.
If blown, replace them.
Replace the brush switch.
If it is working correctly, go to point 7.
If the carbon brushes are intact go to point 8.
Otherwise replace the carbon brushes.
Check the brush motor carbon brushes, see
chapter A2.
If it is working correctly, go to point 6.
Otherwise replace or adjust the microswitch.
Check operation of the brush actuator
microswitch, see paragraph D 2.1.
If the microswitch is working go to point 5.
If there is continuity, go to point 4.
3
Check the instrument panel fuse on the wiring
board, see paragraph D 5.1, D 6.1.
Otherwise replace the fuse.
If the fuse is intact go to point 4.
TROUBLESHOOTING
E2
If OK, go to point 3
If there is voltage, go to point 2
Check the key contact, “BT” only, see paragraph
C 4.2, C 4.3.
71 of 73