background image

Vacuum Oil & Fluid ExtractOr manual 

18ltr

Model no: 

tP6908

thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SaFEty

 

‰

  

WarninG!

 ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this 

equipment.

 

9

   Familiarise yourself with the extractors application and limitations, as well as the specific potential hazards peculiar to this product.

 

9

   Maintain the extractor in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use genuine parts only. non authorised parts will invalidate the warranty.

 

9

   Use only to extract engine or transmission oils, or similar non-Corrosive fluids. Unit may also be used for the transfer of water. 

 

9

   ensure safety eye protection and protective clothing are worn when using this product.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

   Maintain correct balance and footing. ensure the floor is not slippery and wear non slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   dispose of waste liquids in accordance with local authority regulations.

 

8

  

dO nOt

 store fluids in the TP6908 container. once used to extract fluid, it must be emptied into an approved receptacle as soon as   

 possible.

 

8

  

dO nOt

 over tip the extractor when emptying as this may cause fluid to enter the inner pump chamber. See fig.1 

 

8

  

dO nOt

 use to extract hazardous or harmful chemicals, solvents, petrol, diesel, kerosene, alkaline    

 

 

 

  or acids. If by chance such fluids are used in the unit, it must be immediately drained and thoroughly    

 

 

 

  cleaned. Use with prohibited fluids will invalidate your warranty.

 

8

  

dO nOt

 dismantle, tamper or adapt the extractor for any purpose other than for which it is designed.

 

8

  

dO nOt

 use the unit if it has been dropped or mishandled, check the unit to ensure there is no  

 

 

 

 

 damage.

 

9

   Keep the extractor clean and store in a safe dry location. 

dO nOt

 store in areas of high temperature, direct  

    

  sunlight, rain or snow.

2.  intrOductiOn

18ltr Capacity device constructed from composite materials. largest capacity manual extractor on the market. 

Uses manual pump to generate vacuum. Suitable for the extraction of all types of engine, transmission and 

lubricating oil from cars, motorcycles, marine engines, stationary engines and industrial machinery. Also 

suitable for low viscosity fluids such as water. Supplied with Ø5.8 and Ø6.7mm suction probes and Ø9.8mm 

extension tube. Uses probes to extract engine oil through the dipstick tube. Unit can be tipped passed 90° for 

easier emptying. Fitted with three castor wheels enabling easy manoeuvrability when the unit is full.

3.  SPEciFicatiOn

Model no: ..................................................................TP6908

Capacity: .........................................................................18ltr

extension Tube: .......................................................

Ø9.8mm

Suction Probes: ...............................................

Ø5.8, Ø6.7mm

4.  OPEratiOn

4.1.    

Oil  ExtractiOn

4.1.1. 

  

Ensure the vehicle is on level ground and run the engine for approximately 5 minutes to warm the oil 

 

 

and allow any contaminants within the oil to thoroughly mix and turn the engine off.

4.1.2.   

Remove the vehicle’s oil dipstick.

4.1.3.   

Select and insert the appropriate diameter probe (fig.2) into the dipstick hole until it reaches the  

 

 

 

 

 

bottom of the sump.

4.1.4.   

Connect the main suction tube (fig.3) to both the pump inlet and required probe (fig.2).

4.1.5. 

  

Raise the handle to its highest limit and pump it fully several times to create a vacuum which will  

 

 

 

 

 

automatically begin to extract the oil/fluid. observe the oil/fluid as it rises up the chamber and  

 

 

 

 

 

stop pumping when the fluid is 6”(150mmm) from the top. The unit will continue to fill and will  

 

 

 

 

 

automatically shut off when the internal float valve operates.

 dO nOt 

continue to pump after the unit   

 

 

 

 

has shut off as this may result in liquid entering the inner pump chamber. If this should occur refer to    

 

 

 

TP6908 Issue 1 11/12/18

Original Language Version

© Jack Sealey limited

Refer to 

instructions

 Wear eye 

protection

 Wear protective 

gloves

 Wear safety 

footwear

 Wear protective 

clothing

Reviews: