T12 Service Information 9009917 (12-12)
4-63
TROUbLESHOOTING
Vacuum Fan Failed to Turn ON
SteP
action
value(S)
yeS
no
1
•
key on
•
enable scrubbing vacuum fan(s)
•
Is there a pertinent LCd warning or fault message
displayed?
See “LCd
warnings” or
“LCd faults”
Sections
Go to Step #2
2
•
key off
•
See “manual mode” section of this manual
•
activate vacuum fan(s) in manual mode
•
does the vacuum fan(s) turn on?
Go to Step #5
Go to Step #3
3
•
key off
•
See “Self-Test mode”
•
does the Self-Test display output circuits j3-3, or j3-2
as open or shorted?
Correct open
or Short Cir-
cuit Condition
Go to Step #4
4
•
key off
•
See TeSTInG vaCuum fan (SCrubbInG) in the Ser-
vICe section of this manual
•
do the vacuum fan motor pass the testing?
See TeSTInG
vaCuum fan
(SCrubbInG)
Go to Step #5
repair or re-
place vacuum
fan motor
5
•
key off
•
reconnect vacuum fan motor to main wire harness
•
key on
•
enable scrubbing vacuum fan subsystem
•
Test voltage applied to the scrubbing vacuum fan
subsystem as shown on the electrical schematic
•
are the electrical circuits operating as shown on the
electrical schematic?
Go back to
Step #1
Identify volt-
age drop
Location and
repair or re-
place neces-
sary Compo-
nents
Terms:
LCd = Liquid Crystal display
j3-3 = water pu module Connector #3, pin #3
j3-2 = water pu module Connector #3, pin #2