SCRUBBING
3-23
7200 330045 (10--99)
6. Install the screw holding the left front of the
recovery tank to the frame in the area of the
operators compartment. Leave loose for
now.
7. Install the air flush valve mount bracket on
the front of the recovery tank. Tighten all
three screws to 18 -- 24 Nm (15 -- 20 ft lb).
8. Reinstall the vacuum fan on the recovery
tank. Reconnect the vacuum fan to the main
electrical harness. Tighten the hardware to
18 -- 24 Nm (15 -- 20 ft lb).
9. Reinstall the tank cover and plastic hinge
rod.