ELECTRICAL
4-75
7200 330045 (10--99)
When the operator releases the squeegee button,
the controller will run the squeegee and the brush
head actuators to the up positions. It will then run
the following procedure:
1. Turn on the vacuum fan and lower the
squeegee actuator.
2. Wait for the actuator to stall, flag error for
always stalled, early stall, or never stalled.
3. Raise squeegee.
4. Drop scrub head about 2 inches.
5. Run head actuator up.
6. Wait for the actuator to stall, flag error for
always stalled, early stall, or never stalled
7. Check brush motor current with brush
motors off. Flag error for current sensed.
8. Turn on the brush motors.
9. Flag error for zero current, low current, or
high current.
10. Turn off the brush motors.
11. Cycle and test the ES
t
pump output.
12. Cycle and test the ES
t
air flush output.
13. Cycle and test the Vacuum fan output.
14. Cycle and test the Scrub brush motor
output.
15. Cycle and test the Hour meter output.
16. Cycle and test the water valve output.
17. Blink the squeegee light (green) for system
passed, blink the overflow light (red) for
system failed.
Summary of Contents for 7200
Page 1: ...330045 Rev 02 3 02 Service Manual 7200 ...
Page 4: ...GENERAL INFORMATION 1 2 7200 330045 10 99 ...
Page 18: ...GENERAL INFORMATION 1 16 7200 330045 3 02 ...
Page 20: ...CHASSIS 2 2 7200 330045 10 99 ...
Page 76: ...CHASSIS 2 58 7200 330045 10 99 ...
Page 78: ...SCRUBBING 3 2 7200 330045 10 99 ...
Page 156: ...SCRUBBING 3 80 7200 330045 10 99 ...
Page 158: ...ELECTRICAL 4 2 7200 330045 10 99 ...
Page 222: ...ELECTRICAL 4 66 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 1 5 2 3 4 ...
Page 223: ...ELECTRICAL 4 67 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 1 5 2 3 4 ...
Page 224: ...ELECTRICAL 4 68 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 ...
Page 238: ...ELECTRICAL 4 82 7200 330045 10 99 ...
Page 245: ......
Page 246: ......
Page 255: ...ELECTRICAL 4 97 7200 330045 10 99 ...