ELECTRICAL
4-20
7200 330045 (10--99)
CIRCUIT BREAKERS
RESETABLE CIRCUIT BREAKERS
Circuit breakers are resetable electrical circuit
protection devices designed to stop the flow of
current in the event of a circuit overload. Once a
circuit breaker is tripped, reset it manually by
pressing the reset button after the breaker has
cooled down.
If the overload that caused the circuit breaker to
trip is still present, the circuit breaker will continue
to stop current flow until the problem is corrected.
The circuit breakers are located on the operator
console.
The chart below shows the circuit breakers and
the electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB1
10 A
Machine power
CB2
10 A
Battery discharge
indicator
CB3
15 A
Head lights
CB4
10 A
Power wand
CB5
10 A
Horn
CB6
10 A
Instrument panel
CB7
20 A
Vacuum Fan
CB7
40 A
Heavy duty vacuum fan
CB8
25 A
Scrub brush motor
CB9
25 A
Scrub brush motor
Summary of Contents for 7200
Page 1: ...330045 Rev 02 3 02 Service Manual 7200 ...
Page 4: ...GENERAL INFORMATION 1 2 7200 330045 10 99 ...
Page 18: ...GENERAL INFORMATION 1 16 7200 330045 3 02 ...
Page 20: ...CHASSIS 2 2 7200 330045 10 99 ...
Page 76: ...CHASSIS 2 58 7200 330045 10 99 ...
Page 78: ...SCRUBBING 3 2 7200 330045 10 99 ...
Page 156: ...SCRUBBING 3 80 7200 330045 10 99 ...
Page 158: ...ELECTRICAL 4 2 7200 330045 10 99 ...
Page 222: ...ELECTRICAL 4 66 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 1 5 2 3 4 ...
Page 223: ...ELECTRICAL 4 67 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 1 5 2 3 4 ...
Page 224: ...ELECTRICAL 4 68 7200 330045 3 02 WIRE HARNESSES GROUP 000000 008237 ...
Page 238: ...ELECTRICAL 4 82 7200 330045 10 99 ...
Page 245: ......
Page 246: ......
Page 255: ...ELECTRICAL 4 97 7200 330045 10 99 ...