ENGLISH
EN
750 (08–02)
11
C:
RINSING AREA
FOR SAFETY: Do not operate machine unless
safety goggles are worn.
NOTE: Use the gulper tool if the area is not equipped
with a floor drain.
1.
Adjust the spray gun to high pressure by pulling
the spray nozzle inward (Figure 15).
FIG. 15
2.
Activate the pump switch. If using the gulper tool,
press the vacuum/blower switch towards the
vacuum symbol (Figure 16).
FIG. 16
3.
Begin rinsing entire area from top to bottom. Turn
the spray nozzle clockwise to pin–point grout lines,
and to clean heavily soiled and hard to reach
areas (Figure 17).
NOTE: Operating the gun at high pressure will
automatically stop injecting cleaning agent.
FIG. 17
FOR SAFETY: When using machine, do not spray
solution into electrical outlets, switches, fuse
boxes or on electrical appliances.
FOR SAFETY: When using machine, never point
spray gun at a person’s face.
4.
To operate the spray gun at low pressure without
dispensing cleaning agent, turn the cleaning agent
on/off lever to the (O) position (Figure 18).
FIG. 18
5.
If solution tank runs dry while operating, you must
operate the spray gun at low pressure to reprime
the pump. DO NOT OPERATE PUMP DRY.
6.
After thoroughly rinsing the entire area, shut the
machine off. Wipe off solution hose and return the
gun to the storage hook.
ATTENTION: Relieve water pressure from spray
gun before disconnecting hose.