C. Measuring Resistance
(see figure 5)
Warning
To avoid damage to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before measuring resistance.
To avoid possible injury, please do not attempt to input
v o l t a g e s h i g h e r t h a n 6 0 V D C o r 3 0 V A C .
To measure resistance, connect the Meter as follows:
20
Model 72-1016: OPERATING MANUAL
Insert the red test lead into the terminal and the
black test lead into the
COM
terminal.
Set the rotary switch to
, press
SELECT
b u t t o n t o s e l e c t
m e a s u r e m e n t m o d e .
Connect the test leads across with the object being
measured. The measured value shows on the display.
1 .
2 .
3 .
(Figure 5)