Device Management
- 77 -
8.5.2 Configure the SNMP
8.5.2.1 Configuration guidance
The SNMP configuration tasks of Tenda smart PoE switch series are given below:
Procedure
Configure
the
tasks
Specification
1
Enable
the
SNMP functions
Mandatory
SNMP agent function of the switch is disabled by default.
2
Set the SNMP
Community
String
Optional.
The Read only community string
of switch is “public” by
default, and the Read & Write community string is
“private”.
3
Set the SNMP
Trap
Optional.
SNMP Trap function of the switch is disabled by default.
If the switch is not required to aggressively report to
SNMP administrator in case of failure or error, it is
unnecessary to carry out this procedure.
8.5.2.2 Configure the tasks
Please enable the SNMP function prior to other operations described in this section.
Enable the SNMP functions
Configuration procedures:
1.
Log in to the Web network management of the switch, and then go to
Device
management
>
SNMP
configuration page;
2.
SNMP: Click the drop-down box, and select the
Enable
3.
Click
OK