B.
Mold Purge (optional feature not included on all units).
The mold or system purge
system contains several solenoid valves and check valves. When activated and supplied
with compressed air, the mold or system purge system will expel process water from the
mold to the drain. Advantage mold or system purge systems are supplied as a factory
installed option or a field retrofitted kit.
1.
On selecting the mold purge feature, the controller checks to determine if
the pump is running. If it is, then the Unable To Mold Purge Message will be
displayed.
2.
When the pump is not running and when Mold Purge is enabled (refer to Section
3.13 for more information on enabling Mold Purge) Mold Purge is activated by
selecting the mold purge item from the Utilities menu. Mold purge is started
immediately. When mold purge is activated the following screen will show.
3.
Press the back button or the stop button to stop the Mold Purge.
C.
Manual Vent.
Manual venting is achieved by fully opening the cooling valve. To initiate a
manual vent, advance to the Utilities screen and select the Manual Vent item.
1.
Press the Select button to start the venting.
2.
To stop the venting, press the Back button. On release, the screen will return to
the Home screen.
D.
Software Version.
The software version number is the current version of the controller’s
software. This number came be useful when troubleshooting at times.
Summary of Contents for Veteran VT LXG Series
Page 2: ......
Page 6: ...Page 6 THIS PAGE INTENTIONALLY BLANK ...
Page 20: ...Page 20 THIS PAGE INTENTIONALLY BLANK ...
Page 42: ...Page 42 THIS PAGE INTENTIONALLY BLANK ...
Page 48: ...Page 48 THIS PAGE INTENTIONALLY BLANK ...
Page 68: ...Page 68 THIS PAGE INTENTIONALLY BLANK ...
Page 95: ...END 2021 TEMPTEK INC RE 20210323 ...
Page 96: ......