9
www.templari.com
3.2.2 KITA with Scroll Vapor Injection
KITA Si - Si 3Phase - Si Cold - Si Cold 3Phase
- Si Plus - Si Plus 3Phase - Si Plus Cold - Si
Plus Cold 3Phase - Mi - Mi 3Phase - Mi
Cold - Mi Cold 3Phase - Mi Plus - Mi Plus
3Phase - Mi Plus Cold - Mi Plus Cold
3Phase - L33 - L42 - L66 - L66 Cold - Li Plus:
Heat pump
W
at
er output t
emper
atur
e +/-2 [°C]
Outdoor air tempe/-1 [°C]
Chiller
W
at
er
outp
ut
temper
atur
e
+/-2
[°C]
Outdoor air tempe/-1 [°C]
3.3 System structure with heat pump
The system with heat pump includes following components:
•
Heat pump
KITA Templari®;
•
Control command of heat pump;
•
Optional hydraulic components, that can be required to
the manufacturer: a heating resistor for the condensate
drain, una a three-way valve for the combined system and
domestic hot water management, mesh filter, switching
relé operating with boiler integration.
The control of machine functions is totally done by command.
3.4 Components
KITA S - S 3phase - S plus - S plus 3phase -
Si Cold - Si plus Cold - Si Cold 3phase - Si
plus Cold 3phase - Mi - Mi 3phase - Mi Cold
- Mi Cold 3phase: circulator Wilo Para 25/8
iPWM
Model
Wilo Para 25/8 iPWM
Voltage - supply frequency
1-230-V 50/60Hz
Energy efficiency index (EEI)
≤0,21
Maximum power
75 W
Maximum current absorption
0,6 A
Maximum head
8,4 m
Minimum pressure input
0,5 bar
Producible water temperature
From -10°C to 95°C
Characteristic curves of the Circulator
Pressure drop in the plate heat exchanger
Water flow in heating [m
3
/h]
[kP
a]