![Templari KITA L Cold Installation And Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/templari/kita-l-cold/kita-l-cold_installation-and-maintenance-manual_1085667018.webp)
18
www.templari.com
KITA M LINE
WITH LEGS
WITH BRACKETS
A: water inlet connection: Ø 1”
B: water outlet connection: Ø 1”
C: condensate drain - outer diameter 40 mm
D: electrical wiring
KITA L LINE
WITH LEGS
WITH BRACKETS
A: water inlet connection: Ø 1”
B: water outlet connection: Ø 1”
C: condensate drain - outer diameter 40 mm
D: electrical wiring
Bottom
view
DATE :
DRAWN BY :
DESCRIPTION:
Giovanni B.
09/03/2020
WITH BRACKETS
CON STAFFE
WITH LEGS
CON GAMBE
A gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
18mm
B liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
KITA M
SPLIT VERSION
259
1012
1271
225
1134
225
1591
121 122
546
92
221
60
585
C
B
A
D
1591
4
132
1041
202
65
1047
65
205
590
6.3 X 27.5
1112
239
241
121 122
640
92
221
60
C
B
A
D
Bottom
view
A gas flow / passaggio refrigerante (gas)
outer diameter /
diametro esterno
: 22mm
B liquid flow / passaggio refrigerante (liquido)
outer diameter /
diametro esterno
: 12mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
WITH LEGS
CON GAMBE
WITH BRACKETS
CON STAFFE
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA L
SPLIT VERSION
06/03/2020
1513
256
1257
325
1133
325
1791
641
88
289
292
1791
61
136 137
C
A
B
D
1292
35
1257
65
297
1056
65
301
1791
75
1367
678
1791
292
88
336
1121
334
61
289
136
137
11 X 36
C
A
B
D
Bottom
view
A gas flow / passaggio refrigerante (gas)
outer diameter /
diametro esterno
: 22mm
B liquid flow / passaggio refrigerante (liquido)
outer diameter /
diametro esterno
: 12mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
WITH LEGS
CON GAMBE
WITH BRACKETS
CON STAFFE
DATE :
DRAWN BY :
DESCRIPTION:
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
Giovanni B.
KITA L
SPLIT VERSION
06/03/2020
1513
256
1257
325
1133
325
1791
641
88
289
292
1791
61
136 137
C
A
B
D
1292
35
1257
65
297
1056
65
301
1791
75
1367
678
1791
292
88
336
1121
334
61
289
136
137
11 X 36
C
A
B
D
Bottom
view
DATE :
DRAWN BY :
DESCRIPTION:
Giovanni B.
09/03/2020
WITH BRACKETS
CON STAFFE
WITH LEGS
CON GAMBE
A gas flow /
passaggio refrigerante (gas)
outer diameter /
diametro esterno:
18mm
B liquid flow /
passaggio refrigerante (liquido)
outer diameter /
diametro esterno:
12mm
C condensate drain /
scarico condensa
outer diameter /
diametro esterno:
40mm
D electrical wiring /
passaggio cavi ele�rici
TEMPLARI SRL - HEAT PUMP TECNOLOGY
Via Pitagora, 20A - 35030 Rubano (PD)
Tel. +39 049 5225929 - www.templari.com
KITA M
SPLIT VERSION
259
1012
1271
225
1134
225
1591
121 122
546
92
221
60
585
C
B
A
D
1591
4
132
1041
202
65
1047
65
205
590
6.3 X 27.5
1112
239
241
121 122
640
92
221
60
C
B
A
D
Summary of Contents for KITA L Cold
Page 1: ...AIR WATER version Installation and maintenance manual T H E H E A T P U M P...
Page 5: ......
Page 65: ...65 www templari com...
Page 66: ...66 www templari com...
Page 67: ...67 www templari com...