9.7 Terminal block wiring KITA L33/L42/L66
Different variants of terminal block are available according to the
necessity of managing optional devices. Here below the available
versions are listed.
Version 1 - No optional accessories.
C4
NO8
NO9
NO10
NO11
NO12
RX-/TX-
RX+/TX+
GND
Vout
RX-/TX-
RX+/TX+
GND
C1
NO1
NO2
NO3
C2
NO4
NO5
NO6
NO7
C3
NC7
G
G0
B1
B2
B3
B4
B5
B6
B7
GND
+Vdc
+Vdc
GND
+5 Vref
GND
Y1
Y2
Y3
Y4
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DIC1
B8
B9
B10
B11
B12
GND
ID8
ID9
ID10
IDC2
B1
Subcooling
B2
radiant probe
B3
domestic probe
B4
return probe
B5
flowmeter
B6
Head compressor probe
B7
flow probe
B8
outside t. probe
B9
drain probe
B10 suction probe
B11 transducer high
B11 +5V
B11 GND
B12 transducer low
B12 +5V
B12 GND
DI1 summer-winter
DI2 thermal sensor
DI3 press. switch high
DI8 remote on-off
DI10 flow switch
Y2
int fan air-air
Y3
PWM Circulator
GND
+5VR
The B2 and B3 probe must be connected to the prewired cable
provided with the heat pump and locate inside of it.
Version 2 - A relè to manage DHW or auxiliary
integration.
If you want to manage a 3-way valve to domestic management
or for the ignition of an electrical resistance / boiler, the terminal
presents the relè K3 suitabe for this management.
For standard connections make reference to the table shown in
version 1. Here below is shown the table with the contacts for
the connection of the relé K3
K3
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
Relè K3
MANAGEMENT DHW / RESISTANCE / BOILER
A1
Relè coin. To contact NO6 of µPC
A2
Relè coin. To Neutral of external unit.
14
Contact normally open (Na)
12
Contact normally close (Nc)
11
Common Contact ( C )
Connection 3-way valve Templari - de pala
Phase open (BROWN)
Phase close (BLU)
14
12
11
Neutral (BLACK)
Earth (YELLOW - GREEN)
Earth
Neutral
Phase
3-WAY VALVE
DOMESTIC LINE
EXTERNAL UNIT RELÈ K3
3 way:
Brown = Phase open
Black = Neutral
Blu = Phase close
Y/G = Earth
K3
Version 3 - Two relès, to manage DHW and
auxiliary integration.
If you want to manage a 3-way valve for the domestic
management and in the same time the ignition of an electrical
resistance / boiler, the terminal presents two relès: K1 for the
management DHW and K3 for the auxiliary integration.
For standard connections make reference to the table shown in
version 1. Here below is shown the table with the contacts for
the connection of relès K1 e K3.
K3
K1
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
Relè K1
MANAGEMENT DHW
A1
Relè coil. To contact NO9 of µPC
A2
Relè coil. To Neutral of external unit.
14
Contact normally open (Na)
12
Contact normally close (Nc)
11
Common Contact ( C )