Page 2 of 18
OPERATION
1. Verify the power switch is in the off position. Plug your heater & thermocouple into the rear connectors. Plug the provided line
cord from the console into a standard outlet. Switch on the console.
2. Set your desired temperature setpoint by using the up and down arrow buttons on the TEC-9400 temperature controller.
3. Refer to the following pages for complete operation and auto-tuning of the TEC-9400 temperature controller.
SPARE/REPLACEMENT PARTS
Tempco
Description
Part Number
EHD-124-276
(for 1, 2, and 3-zone units) Fuse (1), rated 1 Amp/ 250V, ¼" x 1¼", fast acting,
BUSS ABC-1-R. Used for TEC-9400 Controller
(located inside rear panel mounted fuseholder)
EHD-124-290
(for 4-zone units) Fuse (1), rated 1.5 Amp/ 250V, ¼" x 1¼", slow acting, BUSS
ABC-1 .5-R. Used for TEC-9400 Controller
(located inside rear panel mounted fuseholder).
EHD-124-300
(for 2-zone units) Fuses (2), rated 8 amps, 250V, ¼" x 1¼", fast acting, BUSS ABC-8-R.
EHD-124-279
(for 3-zone units) Fuses (3), rated 5A, 250V, ¼" x 1¼", fast acting, BUSS ABC-5-R.
EHD-124-282
(for 4-zone units) Fuses (4), rated 4 amps, 250V, ¼" x 1¼", fast acting, BUSS ABC-4-R.
EHD-102-113
(for 120V units) Power output plug (1 per zone), Hubbell HBL4720C, 15A 125V Twist-Lock.
EHD-102-121
(for 240V units) Power output plug (1 per zone), Hubbell HBL4570C, 15A 250V Twist-Lock.
(Type of plug dependent on console model ordered)
TCA-101-104 Type “K” thermocouple mini plug (1 per zone), yellow
TCA-101-105 Type “J” thermocouple mini plug (1 per zone), black
TCA-101-136 Type “CU” mini-plug, white (for 2-wire RTD)
NOTE: For all fuses, use listed BUSS part numbers or equivaliant.