Call..
: number or IP address of the phone to contact when the alarm condition is triggered. The input could
be also used as “door opener”: enter the number of the relay preceded by #. For exampe #1 activate the
relay 1, #2 activate the relay 2. The activation time is the one entered in the activation time filed.
•
Attempts:
number of call attempts (max 999)
•
Separation:
separation, in seconds, between a call attempt and the other (max 999).
•
Delay:
it is the minimum time, in seconds, before validating the input. It could be useful, for example, to
mask an open door switch. Supposing the maximum time of a pedestrian gate is 30 seconds, at the end of
this time (if the switch would be still active) an alarm will be send to the reception.
•
Inversion:
the contact is normally open and the alarm occurs at the closing of the same. Enabling this flag it
is possible to instruct the device to behave in the opposite way (the contact is normally closed and the
alarm occurs at the opening).
•
Stop code
:
:
code to dial on the phone calling to accept and acknowledge the alarm (max 3 digits).
•
Announce:
whe activating this input, a prerecorded message will be played on the speaker. See messages
management.
In the screenshot are represented up to six inputs, but only the first three are available on this model, other fields