TEMA TELECOMUNICAZIONI    

                                                                

AD639R VoIP SIP PoE Repeater 

MAS-AD639R-REV00EN 

 

 

 

 

             

       

               Page 12 of 30 

 

1

 Removable 4-pole terminal block (screw connector connected to the electronic module) 

 

+Vout

 

Terminal from which it is possible to withdraw power, POSITIVE 

- (GND)

 

Terminal from which it is possible to withdraw power, NEGATIVE 

A

 

Terminal to power the system, polarity irrelevant

 

C

 

Terminal to power the system, polarity irrelevant 

 
 
 
 
 
 

 

 

 
 

RJ45 LAN port (present on the electronic module) 

 

AD639R requires a LAN cable to connect to the LAN network. If the cable also carries PoE power supply, it will not 
be  necessary  to supply  the  module  with  other  power  sources  (for  max  10W  power).  For  higher  powers  it  will  be 
necessary to power AD639R with a 24Vdc 2A or max 18Vac 2.5A power source. See also appendix 4 at the end of 
the manual for the correct wiring of the LAN cable to the RJ45 connector. 

 

 
 

 

 
 

Removable 9-pole terminal block (screw connector connected to the electronic module) 

 

9 SP1+

  

Output terminal 1st Class-D amplifier, connected to the internal loudspeaker, positive front 

8 SP1-

  

Output terminal 1st Class-D amplifier, connected to the internal loudspeaker, negative front 

 

7 K1.NC 

K1 relay terminal – NC normally closed contact

 

6 K1.CC 

K1 relay terminal – CC central contact 

 

(maximum contacts load max 30V 1.5A)

 

5 K1.NA 

K1 relay terminal – NO normally open contact

 

 

4 K2.CC 

K2 relay terminal – CC central contact 

 

(maximum contacts load max 30V 1.5A) 

3 K2.NA 

K2 relay terminal - NO normally open contact

 

 

2 GND 

Terminal related to the system power supply negative, for the alarm contact

 

1 ING1 

Terminal for detecting the alarm contact

 

 
 
 
 
 
 
 
 
 
 
 

Removable 2-pole terminal block (connector connected to the cable leaving the module) 

 

+

 

Connect here the positive of the flashlight or external device  

- (GND)

 

Connect here the negative of the flashlight or external device 

 

 
 
 
 

 

 

At the "+Vout" output there is a + 12Vdc voltage when the device is powered via PoE, otherwise, at 
this output the voltage will be the same as at the terminals A-C.  The use of "+Vout" is permitted as 
long as it is not exceeded a maximum 200mA current consumption and the load has a protection on 
the input current. Improper use of this output will permanently damage the unit. 
 

Devices  powered  via  PoE  (Power over  Ethernet)  may only  be  connected  with cables  coming  from 
inside  the  building,  they  are  not  allowed  connections  to  LAN  cables  coming  from  outside  the 
building. 

To terminals 1 (ING1) and 2 (GND) must only be connected a relay contact or a button free from any 
voltage to prevent permanent damage to the device. 
 

The  power  supplied  by  this  terminal  is  protected  and  limited  to  300mA  maximum  current,  do  not 
connect devices with a higher power consumption as internal protection would be activated. 

ATTENTION:

  the  voltage  in  these  terminals  is  normally  12Vdc  when  powered  by  PoE  but  may  be 

24Vdc if powered from an external power supply! 

Relay K1 is pre-wired to supply power to terminal 4 which supplies an external flashing light, relay 
K2 is free for other uses by the user. 
 

Summary of Contents for AD639R

Page 1: ...019 First release MM DP DP FL TEMA TELECOMUNICAZIONI IP COMMUNICATION AND SECURITY COMPANY WWW TEMATLC IT Products for VoIP SIP LAN networking Communications Paging Amplifiers Systems and Audio Applications Zone Announcements Night Ringer Multicast general call Background music Standard SIP call or Emergency call SD memory with pre recorded messages Relays for LAN drives ...

Page 2: ...IONE DI CONFORMITÀ CE DECLARATION OF CONFORMITY CE The crossed out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in an unsorted municipal waste in order to provide for the treatment of WEEE Waste Electrical and Electronic Equipment using best available recovery and recycling techniques Specific treatment for WEEE is in...

Page 3: ... Products powered via PoE Power over Ethernet may only be connected with cables coming from the internal network company inside the building are not allowed connections LAN cables coming from outside the building 7 Use for this device only and exclusively original spare parts and consumables supplied by Tema Telecomunicazioni The company is not responsible for damage caused by the use of materials...

Page 4: ...1 8 1 CONNECTING THE AD639R INTERNAL MODULE 11 9 PROGRAMMING 13 9 1 PREPARATION FOR THE SYSTEM PARAMETERS PROGRAMMING 13 9 2 ACCESS TO PROGRAMMING 15 9 3 NETWORK PARAMETERS 16 9 4 SIP PARAMETERS 17 9 5 ALARM INPUT SETTINGS 18 9 6 MESSAGES MANAGEMENT 19 9 7 AUTOMATIC ANNOUNCEMENTS 20 10 MAINTENANCE 22 10 1 SYSTEM 22 10 2 LOGIN CREDENTIALS 23 10 3 DIAGNOSTIC LOGS 23 10 4 MULTICAST AUDIO STREAMING FO...

Page 5: ...umber assigned to AD639R in the night group of the PBX or divert incoming calls in the absence of the PO to the number assigned to AD639R Some models of AD639R can be supplied with a LED or FLASH Xenon optical indicator in different colors to add a light signal to the acoustic signal The luminous indicators are also available separately and can also be mounted later on outside the device with the ...

Page 6: ...D639R FT With transparent Xenon FLASH flashing light AD639R FR With red Xenon FLASH flashing light Optional accessories AA 39E3 DIN Power Supply 220Vac 24Vdc 1 5A AD699 X10B FLASH transparent Xenon flashing light for external connection AD699 L10A Flashing orange LED for external connection AD699 X20R Flashing red Xenon FLASH for external connection AD699 RT Adjustable support in horizontal and ve...

Page 7: ...bined with ease of use and programming P2P SIP Peer to Peer mode for alarm reporting Power supply via PoE Power over Ethernet 802 af with a single UTP cable for the connection or from an external power supply even simultaneously Programming via integrated Web Server interface and password protection Possibility of software firmware update via LAN Integration with local LAN Ethernet LAN 100 BaseT p...

Page 8: ...960 min 16H audio Bandwidth 350Hz 6KHz Power D Class Amplifier 40W on 4 Ohm Acoustic pressure 100dB A SPL Dispersion angle 110 2KHz Audio communication Unidirectional Inputs from buttons or external contacts 1 for alter alarm Integrated relais 2 Relays load capacity Max 30Vdc 1 5A Signalings Active Call Led Installation Wall mount adjustable with optional accessory Container material Halogen free ...

Page 9: ...vice for Multicast streaming sound broadcast In this case the RTP audio broadcast on the network is reproduced amplified to a different volume than that used for the ringer useful for background music or warning messages Finally the status change of an incoming alarm is always monitored to which it is possible to associate a user to call and a message to be played to the answer of the called 6 1 D...

Page 10: ...eaming in unidirectional mode 7 2 RELAY function The internal relays can be used to connect any external flashers In programming it is possible to decide whether they should be activated during the ringing of the incoming call If they are not programmed to be activated during the call they can also be controlled using the Tema ADAM software Audio Domain Access Management software 7 3 Calls generat...

Page 11: ...personnel operate verifying that no cable is live also strictly comply with the indications of the voltage and current values for the power supplies and other parts of the system Follow the instructions given in the block diagram for the correct electrical connection of the system On the following page the detail of each terminal will be shown 9 8 7 6 5 4 3 2 1 C A 4 3 2 1 A C 9 8 7 6 5 4 3 2 1 1 ...

Page 12: ...acts load max 30V 1 5A 3 K2 NA K2 relay terminal NO normally open contact 2 GND Terminal related to the system power supply negative for the alarm contact 1 ING1 Terminal for detecting the alarm contact 4 Removable 2 pole terminal block connector connected to the cable leaving the module Connect here the positive of the flashlight or external device GND Connect here the negative of the flashlight ...

Page 13: ...nect to the web interface of AD639R it is necessary that in the IP addresses configuration of your PC is present the subnet 192 168 0 x where x is any number between 1 and 254 and different from 10 See below how to configure your PC to reach the correct subnet The shown procedure applies to Windows operating systems Open the Windows Control Panel and set the field View by Category Large Icons or S...

Page 14: ...ber the current TCP IP configuration of your computer for any subsequent restore of the correct parameters Click Use the following IP address and type in the appropriate field the following IP address 192 168 0 11 instead of 11 used in the example it is possible to enter any number between 1 and 254 but excluding the 10 which is the default address of the system to be programmed In the Subnet Mask...

Page 15: ...e to change the administrative password for the maximum safety of your device Once logged in it is possbile to change the administrative password for the maximum safety of your device The use is very simple and intuitive it is always visible on the left the menu for selecting the functions to be programmed while on the right is shown the configuration window that is currently active Any change wil...

Page 16: ...f necessary change the network segment of your computer so that it can connect to the new address IP address specify the IP address you want to assign to AD639R Subnet mask indicate the subnet mask to be assigned to AD639R Default gateway indicate the gateway that can enable AD639R to access to internet Primary and secondary DNS server indicate the addresses of two DNS servers you want to use to r...

Page 17: ...sion which obviously must have been already created on the PBX Volume it is possible to set the volume used to reproduce the sound of Night Ringer It is also the volume used to reproduce the prerecorded announcements Ampli on indicates whether to activate the amplifier during the call Relay 1 for the entire duration of the call it is possible to keep the relay1 activated It can be used for example...

Page 18: ...ity an appointed operator A prerecorded message is played back to the called party It is possible to invert this logic so the triggering of the signaling can occur following the opening of the contact connected to the input AD639R continuously monitors the status of the contact and in the event of activation it will begin to call the person who will manage the situation detected on the programmed ...

Page 19: ... the relative option is active in the alarm programming screen par 9 5 and when the corresponding input is activated The message is broadcasted before making a call to a telephone Finally the Night Ringer message is the one reproduced during the general night call par 9 4 Audio Multicast Streaming By enabling this feature AD639R will listen to the specified address port and can reproduce on its sp...

Page 20: ...onds set It is also possible to manually activate the message with the Activate now button or stop playback with the Stop button If the manual activation mode is only used it is not necessary to indicate the start time The message reproduced is the alarm announcement message found in the Messages management section Periodic activation from table if this function is activated it is possible to indi...

Page 21: ...elf in the document In the example it was indicated that on September 7 of each year message 1 should be reproduced at 09 00 message 2 at 12 30 and message 3 at 17 30 It is possible to program messages from 1 to 6 but the system only uses message number 1 NOTE1 the volume of reproduction in the case of broadcast on local loudspeaker is the one set as the volume of ringer in the programming mask SI...

Page 22: ...TEMA using the Browse Update Once you ve uploaded the new version the device must be restarted License enter in this field the license key to activate any additional services such as the use of messages over 16 seconds Backup and restore it is possible to save the current settings to restore them in case of a programming error or device replacement Reset to factory settings all settings are lost a...

Page 23: ...it is possible to change the login credentials 10 3 Diagnostic logs To identify small configuration problems it is possible to activate a diagnostic summary on the activity of the VoIP channel of the device Simply connect via TCP port 9991 with Telnet or a terminal like Hyperterminal It is also possible to view the history of activities for each module by clicking Last log The log is deleted when ...

Page 24: ... up to 16 multicast addresses with its own playback volume The audio supported by this mode is in the G 711 aLaw or µLaw G722 or linear 16 bit high quality format proprietary format spread through the AD615 S with an AD696 BM microphone base a phone with function keys for multicast transmissions or an Intercom AA 540 Example 1 In a plant there are two systems connected to the same network switch F...

Page 25: ... A luminous indicator or a Flash available in the catalog can be connected to the system to add a light signal in addition to the acoustic signal Is the sound played as a call repeater fixed No it is possible to replace it at any time remotely via Web Browser between different supplied audio files It is also possible to insert one customized by the customer in the 8KHz 16bit wav audio format as sp...

Page 26: ... For example in a school it can reproduce the sound of the bell for the beginning and the end of the lessons in a factory the notice of beginning end of the working time It is possible to import an Excel file for an annual programming UTP cat 5 6 cable PO and internal network phones PoE Switch IP PBX SIP SERVER 1st Relay 2nd Relay Free for other uses LED light indicator Camera with Motion Detectio...

Page 27: ...relay Tema code AA 36 as shown in the diagram For correct connection refer to the AA 36 technical manual AA 36 Protected Power Relay Actuator 250Vac 16A 4KVA command in AC DC 12V 24V 1 contact Led contacts protected by electric arcs Ideal for driving loads up to 4 000W 230Vca Max Load 4KW SIP telephone for multicast audio streaming calls e g Grandstream GXP2130 or GXP2140 with 4 function keys to t...

Page 28: ...e previous recording simply select the audio track crawl from start to finish press the Delete button and repeat the recording With this procedure it is also possible to delete small parts of silence or sound inside the track 3 To save the recording click on File Export Audio give a name and select in the WAV Microsoft 16 bit PCM format drop down list The saved file is ready to be used on all devi...

Page 29: ...e wires some additional millimeter Hold with one hand the wires and with the other pull the smoothing sheath Straighten the wires previously individually pair twisted Compose the color sequence following the pattern Level the length of the cables into place Insert the tightened wires into RJ45 connector holding them between your fingers until they are channeled into the guides inside the connector...

Page 30: ...TEMA TELECOMUNICAZIONI AD639R VoIP SIP PoE Repeater MAS AD639R REV00EN Page 30 of 30 Notes ...

Reviews:

Related manuals for AD639R