Tema Telecomunicazioni AA-539 Technical Manual And Installation Manual Download Page 13

TEMA TELECOMUNICAZIONI SRL

                                

               

Doorphone AA-539 

MAS-AA539-REV02EN 

 

   

 Page 13 of 57 

 
5.  OPERATION 

 

When, in standby condition, someone press the call button on the AA-539 base system or is dialed a  number on 
the  AA-539K  numeric  keypad,  the  doorphone  automatically  generates  a  telephone  call  through  the  connected 
internal extension of the PBX. 
 
In systems equipped with video camera, this is activated at the beginning of the call and the images made available 
on the connected monitor, until the end of the conversation. There are other operating modes available, such as to 
keep it always on or off. 
 
The  visitor  begins  to  listen  from  the  louspeaker  of  AA-539  the  result  of  his  access  request  whether  or  not 
accompanied by a  voice  message. The  visitor will then  hear the first ringing control tone, then the reply from the 
operator who was called by AA-539. 
 
The  operator  who  answered  may  then  decide  to  activate  the  electric  lock  directly  typing  the  correct  sequence  of 
programmed  DTMF digits (door opener code). After the opening pulse, the audio connection can be automatically 
closed or the operator himself can type on the keyboard of his phone the hang up code or simply hang up (AA-539 
will  detect  the  reorder  tone).  In  addition,  a  programmable  conversation  time-out  provides  to  limit  the  maximum 
duration of the call. When there are  less than 30 seconds after the expiry of timeout, AA-539 will play a warning 
tone. It is possible to extend the duration of the call by typing the recharge time code. 
 
It is also possible for the operator or other extensions, to reach the telephone number where AA-539 is connected 
for example to make a programming, to change the operating mode or to directly activate the two integrated relays. 
 
It is possible, within certain limits, to adjust the  loudspeaker output level and the microphone sensitivity of AA-539 
in order to better adapt to the acoustic characteristics of the area or environment where it is installed. It may be the 
case  that  when  AA-539  is  installed  in  particular  area  or  gates,  the  audio  conditions  are  particularly  "difficult"  and 
you  hear  the  typical  Larsen  effect  due  to  feedback  during  the  conversation.  The  characteristics  and  the 
loudspeaker  level  and  microphone  adjustments  of  AA-539  are  made  at  the  factory  and  normally  allows  to 
overcome these situations without having to take other special precautions. Finally, there is the possibility to enable 
the noise reduction to improve the calls audio quality. 
 
AA-539  allows  to  manage  the  two  built-in  electromechanical  relays  in  two  different  modes,  active  with  normally 
closed  contact  and  active  with  normally  open  contact.  In  the  first  case,  when  the  operator  gives  the  activation 
command,  the  relay  is  activated  while  in  the  second  case,  the  exchange  of  the  relay  (normally  activated)  is 
deactivated at the reception of the command. 
 
AA-539  and  its  expansion  modules  AA-539K,  AA-539R  have  the  possibility  to  activate  an  internal  heating  circuit 
that can be inserted via an internal jumper. AA-539 and its expansion modules also have the possibility to activate 
the  label  holder  backlighting  or  keyboard  backlighting  in  a  fixed  way  or  in  some  cases  also  automatically  when 
switching  between  Day  and  Night  mode.  The  backlight  is  activated  permanently  via  an  internal  jumper  and 
automatically through the built-in second relay (by properly connecting power supply and contacts). 
 

5.1. 

Numeric keypad expansion 

 
Adding the AA-539K  expansion it  is possible to  have the telephone keypad that allows some additional services. 
There  is  for  example  the  possibility  for  the  visitor  to  directly  call  a  phone  number,  or  to  call  the  numbers 
(appropriately  pre-programmed  in  the  parameters)  of  the  Speed  Dial  operating.  See  for  example  the  case  of  a 
possible  visitor  who  goes  to  the  entrance  of  a  building  site  and  among  the  dozens  of  companies  on  the  job  site 
must conctat one in particular: just provide a legend in the proximity of the device that has the instructions and the 
various  numbers  to  call  to  get  in  touch  with  the  person  of  each  company.  The  same  operation  mode  may  be 
applicable in public facilities, large buildings and other environments. The calls (if allowed by the appropriate class 
of service of the extension number assigned to AA-539 on the PBX) can also be made to mobile phones or trunks 
and not only just to the extensions of PBX to which it is connected. 

 

It is also possible to compose only the final part of the number using the operation mode with a root number. In this 
case the system prepends to the dialed  number on the keypad a pre-programmed prefix. For example, if the root 
number  is  "3"  and  the  user  types  on  the  keyboard  "14",  the  system  will  associate  the  prefix  and  dial  the  number 
"314".  This service is also found useful to mask the true extension number of the person to contact. 

 

In addition, this field or service may be used to avoid to make calls directly from the system, when equipped with a 
AA-539K  keypad,  engaging  the  external  lines  of  the  connected  PBX.  In  fact,  if  a  visitor  will  try  to  make  dial 
02123456,  the  system    will  call  302-123456  preventing  the  external  call.  The  direct  dialing  mode  is  NOT  an 
alternative to the speed dialing mode and can both work. 

Summary of Contents for AA-539

Page 1: ...damage caused by the use of materials that they have not supplied 2 The device has been carefully manufactured and tested In any case the product is not recommended for use in situations in which incorrect operating may result in damage to persons and or property 3 We recommend that you carefully read all this manual before starting to use the device 4 Do not expose the device to sunlight and prot...

Page 2: ...l requirements and other relevant requirements of the R TTE Directive 1999 5 EC 2006 95 EC 2004 108 EC The product is in conformity with the followings standards and or other normative documents HEALT SAFETY EN 60950 1 2006 A11 2009 A1 2010 A12 2011 EMC EN 55022 2010 EN 55024 2010 EN 61000 3 2 2006 EN 61000 3 3 2008 TERMINALE DI ES 203 021 Access and Terminals AT Harmonized basic TELECOMUNICAZIONE...

Page 3: ...ling techniques Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants and other hazardous substances into the waste stream while recycling leads to reduction of disposal of waste and the negative impacts on environment and human health That is priority is given to reuse of WEEE in its components subassemblies and consumables As the final holder the user has an...

Page 4: ...539K 26 8 3 3 CONNECTING THE SYSTEM EXPANSION AA 539R 27 8 3 4 CONNECTION OF THE BASE SYSTEM AA 539C WITH CAMERA 28 8 4 DESCRIPTION OF THE TERMINAL BLOCKS OF RELAYS 29 8 4 1 SOLID STATE RELAYS AND ELECTROMECHANICAL RELAYS 29 8 5 DESCRIPTION AND EXAMPLES OF OPERATION MODES WITH THE INTERNAL RELAYS CONNECTIONS 30 8 5 1 CASE 1 DRIVE OF TWO ELECTRIC LOCKS WITH SYSTEM POWERED WITH EXTERNAL POWER SUPPLY...

Page 5: ...TEMA TELECOMUNICAZIONI SRL Doorphone AA 539 MAS AA539 REV02EN Page 5 of 57 9 7 EXAMPLES OF PROGRAMMING OPERATOR COMMANDS 50 10 INFORMATIONS FOR THE WALL INSTALLATION OF THE SYSTEMS 52 ...

Page 6: ...n without the request for access from an outside visitor The base system in version with electromechanical relays is the model AA 539 The base system in version with electromechanical relays and amplified audio is the model AA 539A The base system in version with solid state relays is the model AA 539H The base system in version with solid state relays and amplified audio is the model AA 539HA The...

Page 7: ...thout the intervention of the operator eg useful to service personnel or external assistance which for work reasons frequently comes out and return back in company Since the system has only one button it is suggested to use this service only with the AA 539K expansion Up to 200 programmable access codes to allow to access to the company directly from the doorphone without the intervention of the o...

Page 8: ...nual Adapter for connecting the output video over twisted pair AA 539K expansion consists of the parts included in the following list An AA 539K module full numeric keypad Cable for connection to the base unit AA 539 A special key for the front panel screws AA 539R expansion consists of the parts included in the following list An AA 539R module Legend A special key for the front panel screws It is...

Page 9: ...cal SS solid state cells with gray background indicate the services obtained with AA 539 powered only by the telephone line The following table shows for each system with camera the main features that characterize it and the required needed configuration AA 539C AA 539AC AA 539HC AA 539HAC Amplified Audio Yes Yes Doorphone and conversation Yes Yes Yes Yes Relay drive EM EM SS SS Fixed Backlight Au...

Page 10: ...AA 539K is connected and powered directly from the base unit via a supplied cable expanding the functions of the base system Expansion AA 539K Expansion AA 539R Numbers of buttons Telephone Keypad Yes Door opening codes Yes Button matching to the phone number Yes keys from 1 to 9 Direct number dialing Yes Speed dial Yes Possibility of filter prefix digits Yes Backlighting Yes legend and keyboard Y...

Page 11: ...12V Difference of potential between 3 power sources that can be connected to AA 539 system relay 1 relay2 1500V Insertion type terminals for relays and other Possibility to use cables up to 1 5mm 2 or AWG16 Material of the container INOX steel 316L Steel button Mounting type Flush mounting wall mounting with accessory AA 549 S IP grade of protection IP66 with system correctly installed Operating T...

Page 12: ...input and the common point of the dedicated connector TB6 Time to detect the change state Closing or opening of the external contact for at least 100 milliseconds any activations for less time will be ignored Voltage for detection of the state of the contacts max 12VDC the system has this voltage on the input terminals for detecting the closing of the contacts Current for detection of the state of...

Page 13: ... built in electromechanical relays in two different modes active with normally closed contact and active with normally open contact In the first case when the operator gives the activation command the relay is activated while in the second case the exchange of the relay normally activated is deactivated at the reception of the command AA 539 and its expansion modules AA 539K AA 539R have the possi...

Page 14: ...meters of the system the system restores the Day mode The active mode is stored in the system also when system is powered off and then when it reactivate itself its active mode will be restored if the phone line is disconnected and then reconnected for example 6 2 DAY NIGHT mode with call repetition to the same number To activate this mode should be set up properly its parameter parameter 118 The ...

Page 15: ... Speed Dial service The Speed Dial feature single digit of the keyboard behaves as pressing a button on the base system and it is also adjusted according to the parameter 118 about the operation in Day Night mode Day Night with repeating calls or Group mode In practice for the user it is as were added 10 more buttons that can be used By directly dialing the number to call on the keyboard may be po...

Page 16: ...iar with the various preset access codes It is possible to set up to three access codes for each relay one common always active if set one vaild only in Day mode and another one for Night mode only The parameters to set are 124 125 126 for the relay 1 and 164 165 166 for the relay 2 Since the system have only one button is advides to use this function only with AA 539K expansion because with only ...

Page 17: ... doorphone through a video surveillance system of the gate or if some vehicle arrived at the entrance driveway or as announcer to serve certain areas of warehouses without using a more complex system of public address audio diffusion Calling the extension number connected to the AA 539 system it will answer after the number of rings specified by the parameter 136 In conversation the caller has the...

Page 18: ...s or from the input 3 3 beeps For each input it is possible to define a code acquisition acknowledgment of the alarm signal that the called person must type to inform AA 539 of taking charge of the alarm as notified These codes are defined in the parameters 192 193 194 respectively for input 1 2 3 If the called number is busy or does not answer or in any other case in which AA 539 still does not r...

Page 19: ...n parameter 119 close call 2 Activate the door opener contact of the relay 2 Used to activate the second relay during communication it is a code from 1 to 4 digits default 2 Defined in parameter 141 Warning the function is also regulated by the parameter 144 that should be set to 0 to allow the operator for the function described here 3 Set the DAY mode Sets AA 539 so that the pressure of the call...

Page 20: ...h the system in conversation the Led follows the level of voice and also indicates the presence or absence of dialing tones In the second mode of operation that can be set using the parameter 156 when the system is busy the Led lights steadily and remains lit for the duration of the conversation Below are showed the parts on the system and their function The model shown below is the model AA 539C ...

Page 21: ... to the edges between the back box and the wall itself there is the possibility to insert between frame and box then flush with the wall a special accessory called AA 549 C This one improves the aesthetics of the system in the case the wall is made of a material that can not be cut or not match to the inner metal box Moreover this flat frame applied between the wall and the aluminum frame of the s...

Page 22: ...may be left between the wall and the front of the system For installation of this accessory see the steps on the previous page The inner recessed metal box is the anchoring element of the plain frame and of the front of the system when closed with the special front screws RAIN SHIELD cover Accessory option AA 549 T This shield of non invasive looking can be added to the system to protect it from r...

Page 23: ... consider whether or not to use the four holes labeled B You must use A holes anyway Open also the holes C that you want to use for the passage of cables in the same way Place the protection metal box SC directly on the wall to mark the holes to be made for fixing it Perform drillings on the wall for the provided anchors for fixing finally place the metal box and tighten the screws of the anchors ...

Page 24: ...legend areas The front panel of the expansion includes a backlit transparent field useful to give informations for visitors The model AA 539R specially designed possesses even two areas Because the informations to be presented can be variables for text and graphical form TEMA has provided a practical system of information badges customizing in a file can be edited directly by the person that insta...

Page 25: ...e in a particularly noisy environment FC Polarized connector for connection of the expansion cable to the AA 539K systems For details of the connection of the signals on terminal blocks TB1 and TB3 for the relays see section 8 4 Once that the rear metallic box of the system is arranged in the wall take the front panel with the electronic board insert the two transparent plastic pins present on fra...

Page 26: ...cian Take the cables that have been prepared by one of the outgoing access on the base system and start connecting Remove connect and replace the terminals according to the connections to be made To make the connections never remove the system board from the front panel but just remove the insertion connectors H Jumper for internal heating circuit L Jumper for backlighting circuit FC Polarized con...

Page 27: ...red by one of the outgoing access on the base system and start connecting Remove connect and replace the terminals according to the connections to be made To make the connections never remove the system board from the front panel but just remove the insertion connectors H Jumper for internal heating circuit L Jumper for backlighting circuit TBE2 Terminals for connection of an additional power sour...

Page 28: ... terminals for connecting the telephone pair described above This accessory is suitably protected against accidental contacts being electrically insulated from its metal parts with the use of a special protective thermoformed shield Immediately near the operator monitor must be connected on the same pair another balun who will present the video signal to the monitor on a male BNC connector which c...

Page 29: ...tainly independent of the number of drives compared to electromechanical component The two types of relays when used in the circuits of AA 539 allow to get the use of the system in different conditions as described below The systems equipped with electromechanical relays have the following characteristics to operate the relays is necessary that the system is powered with external power adapter AA ...

Page 30: ... note that is needed to connect the terminal blocks TB1 TB3 TB4 as shown the power supply is unique and common The telephone line must be connected on the TB2 terminal block The connections to be made during the stages of installation are shown in dashed lines In this example the correct values of the parameters involved in the management of the relays could be parameter 138 0 the relay1 is activa...

Page 31: ...upply of AA 539H that feeds itself from the telephone line connected to the terminal block TB2 The connections to be made during the stages of installation are shown in dashed lines This mode of operation can not be achieved with systems equipped with electromechanical relays In this example the correct values of the parameters involved in the management of the relays could be parameter 138 0 the ...

Page 32: ...Note the distinct connections on the blocks TB1 TB3 and TB4 The telephone line must be connected on the TB2 terminal block The connections to be made during the stages of installation are shown in dashed lines Using the possibilities of connection of the power supplies and loads offered by AA 539 it is possible to get a great flexibility of use in driving loads with different electrical characteri...

Page 33: ...s the possibility of bringing the external power supply to the terminal block TB1 3 4 and to re take it to power to the system from the terminal TB1 1 2 to the terminal TB4 1 2 allows to make all the necessary connections without ever being forced to insert two wires into a single terminal block a practice to be avoided in electrical systems where and when possible In this example the correct valu...

Page 34: ...ion of the relay1 that a person is entered in the warehouse Automatically every time a visitor will open the gate is carried out an alert for the present TB3 is designed for use only contact relay2 the system is powered on TB4 on TB1 connects the electric lock and on TB2 the telephone line In this example the correct values of the parameters involved in the management of the relays could be parame...

Page 35: ...he system is correctly placed in Night mode For this service is needed to bring the same system power supply from TB1 to TB4 and then to establish a connection also between TB5 and TB3 as per drawing The telephone line must be connected on the TB2 terminal block Caution with the system set up in this mode the jumper L on the board must be left open In this example the correct values of the paramet...

Page 36: ...der normal conditions AA 539 continuously monitors the status of its three inputs and the respective external contacts connected In case a contact is triggered AA 539 stores it in a non volatile memory EEPROM and provides to start the notification cycle In event of physical disconnection of the telephone line with AA 539 power off the phone alerts will be resumed at the system power on Note perfor...

Page 37: ...wer the only base system with AL 39AL on TB4 Connect the base system with the keyboard expansion using the FC flat cable supplied with the expansion module Then connect the terminal TB5 of the base AA 539 with the terminal TBE3 of the expansion AA 539R see next page for details AA 539 AA 539K three AA 539R modules Keep in mind the power consumption of all modules that are going to be connected wit...

Page 38: ... Page 38 of 57 AA 539 AA 539R AA 539R Power supply 12Vac AA 539R AA 539R AA 539R Power supply 12Vac 8 5 9 Connecting AA 539R modules in cascade starting from a AA 539 base module 8 5 10 Connecting AA 539R modules in cascade starting from a AA 539R powered module ...

Page 39: ... instructions Call the number where AA 539 is connected Wait for the AA 539 answer Insert 3 time star key Wait for a long confirmation beep Insert programming password code default 1234 Wait for a long confirmation beep Insert 110 parameter 110 Wait for a long confirmation beep Insert 220 parameter value Wait for a short confirmation beep Insert confirm data and store it Wait for a long confirmati...

Page 40: ...pound key digit It is a special parameter for signaling only and it has not an associated value AA 539 will play 2 series of beep tones You must count the number of beeps played This number is the firmware version installed The firmware version is always composed by 2 digit the first one is the number of the first series of beep the second one is the numbers of the second series of beeps A pause o...

Page 41: ...meter 123 This number may be associated to a guardian or to an available person that can be available Range max 16 digits values 0 9 pause of 0 5 seconds 119 Call closing command Command to hang up the current conversation to force the system in standby mode It may be equal to the open relay1 code parameter 120 Range max 3 digits values 0 999 0 127 Conversation time extension Command to keep alive...

Page 42: ...x 1 digit value 0 4 0 159 Answer code from AA 539K keyboard Code to digit on the AA 539K expansion to force AA 539 to answer at an incoming call when the parameter 158 is set to value 4 Range max 4 digits values 0 9999 00 138 Relay 1 activation mode Relay 1 activation mode 0 Activated from the telephone command or from access code It remains active for the time set in the parameter 137 eg opening ...

Page 43: ...ameter 128 to allow the visitor to insert the rest of the access code 125 Access code to activate Relay 1 in NIGHT mode As above for relay 1 in NIGHT mode 126 Access code always valid for Relay 1 As above for relay 1 code always valid in all operating modes 164 Access code to set ON Relay 2 in DAY mode External access code to activate relay 2 in DAY mode Range from 1 to 5 digits only one button eg...

Page 44: ... 600 103 Min busy tone reorder time Indicates the minimum duration time in milliseconds of presence of busy tone reorder The value must be smaller than the tone to be recognized Range max 4 digits values 10 9999 50 104 Max busy tone reorder pause time Indicates the maximum duration time in milliseconds of the absence of busy reorder tone The value must be greater than the absence of tone to be rec...

Page 45: ...ed Range max 1 digit values 0 1 1 Keep enabled 143 Camera Activation 0 Standard mode 1 Activation subjected to the presence of the number dialed by the caller in the table defined in the parameters 241 250 Range max 1 digit values 0 1 0 171 Camera operating modes Indicates how AA 539 manages the camera It can be always off always on or activated only during the conversation with the visitor as a r...

Page 46: ...nge max 2 digits values 0 9 3 187 Interval between attempts alarms notification Indicates the interval in seconds between one notification attempt and the next for each alarm Range max 4 digits values 0 9 300 188 Detection mode of the contact associated with the input 1 Defines how AA 539 detects the activation of contact 1 0 to the closure of a normally open contact 1 to the opening of of a norma...

Page 47: ...r for notify alarm 2 Range max 16 digits values 0 9 pause of 0 5 seconds 253 Number to call associated with the input contact 3 Telephone number for notify alarm 3 Range max 16 digits values 0 9 pause of 0 5 seconds 254 9 5 Standard greeting messages AA 539 can play up to two concatenated messages as messages of greeting alert to the visitor Each voice message can have a maximum duration of 7secon...

Page 48: ... N Same as parameter 70 but for the 4 key 215 Speed Dial 5 N Same as parameter 70 but for the 5 key 216 Speed Dial 6 N Same as parameter 70 but for the 6 key 217 Speed Dial 7 N Same as parameter 70 but for the 7 key 218 Speed Dial 8 N Same as parameter 70 but for the 8 key 219 Speed Dial 9 N Same as parameter 70 but for the 9 key 178 Code from additional keypad for issue of DTMF tones Code to ente...

Page 49: ...s composed of 4 digits In addition it is necessary to insert an additional digit that will be the number of the relay which is activate according to the following convention 0 No activate relays 1 Activate relay 1 2 Activate relay 2 3 Activate relays 1 2 Range 5 digit values 0 9 3199 Additional access code number 199 It contains the additional access code number 199 and its associated realy The co...

Page 50: ...consider the dialing of certain numbers as valid or not and then allow or ignore the dialing Note The entered digits can also be considered as a prefix to enable disable all the numbers that begin with a certain sequence and must end with the same character star For example entering 1 in the parameter 230 and 9 in the parameter 231 all the selections starting with 9 digit number will not be consid...

Page 51: ...tion Enter 114 parameter of the number associated with Night button Wait for the long beep of confirmation Enter 0 3451234567890 number to call including the area code prefix to get the trunk line and a pause of 0 5 seconds between the trunk line get and number dialing Wait for the short beep of confirmation Enter Wait for the long beep of confirmation Enter 0 or hang up hang up The system is now ...

Page 52: ...t is mandatory to recess his metallic back box to the wall then securing the front panel To facilitate the finishing and the system wall junction there is the possibility to use the wall cover metal frame accessory called AA 549 C1 If the accessory is not provided the front panel of the system with its frame will simply go directly to the wall fixed to the metallic recessed back box To have a rain...

Page 53: ...e cables between one back box and the other without having to run other pieces of corrugated tube To facilitate the finishing and the system wall junction there is the possibility to use the wall cover metal frame accessory called AA 549 C2 with 2 positions side by side If the accessory is not provided the front panel of the systems with its frame will simply go directly to the wall fixed to the m...

Page 54: ...e cables between one back box and the other without having to run other pieces of corrugated tube To facilitate the finishing and the system wall junction there is the possibility to use the wall cover metal frame accessory called AA 549 C3 with 3 positions side by side If the accessory is not provided the front panel of the systems with its frame will simply go directly to the wall fixed to the m...

Page 55: ...TEMA TELECOMUNICAZIONI SRL Doorphone AA 539 MAS AA539 REV02EN Page 55 of 57 Page for the installation of a single system with the overall dimensions of the various solutions ...

Page 56: ...TEMA TELECOMUNICAZIONI SRL Doorphone AA 539 MAS AA539 REV02EN Page 56 of 57 Page for the installation of two side by side adjacent systems ...

Page 57: ...TEMA TELECOMUNICAZIONI SRL Doorphone AA 539 MAS AA539 REV02EN Page 57 of 57 Page for the installation of three side by side adjacent systems ...

Reviews: