background image

 

 

 

 

39 

 

 

5.14.2

 

Trip settings 

Trip  window  offers  user  to  configure  Trip  feature.  If  Trip  is  enabled  configuration  of 

parameters are enabled.  

Start  Speed  –  GNSS  speed  has  to  be  greater  than  the  specified  Start  Speed  in  order  to 

detect Trip Start.  

Ignition Off Timeout – timeout to wait if ignition was off, to detect Trip stop.  
Continuous  distance  counting  –  Not  or  Continuous  can  be  chosen.  For  this  feature  I/O 

Odometer must be enabled (see Figure 26).  

If I/O Odometer is enabled and Continuous distance counting variable is set to Continuous, 

Trip

 

distance

  is  going  to  be  counted  continuously  (

from  Trip  start  to  Trip  stop

).  This  value  is 

written to I/O Odometer value field. When Trip is over and next Trip begins, Odometer value is 
reset to zero. When the next trip starts counting continuously starts from the beginning again.  

If  I/O  Odometer  is  enabled  and  Continuous  Distance  Counting  variable  is  set  “Not”,  then 

the distance is going to be counted only between every record made. This value is written to I/O 
Odometer value field and reset to zero every new record until Trip stops. If later all Odometer 
values are summed up manually, the user gets the distance driven during the whole period of the 
Trip. 

 

 

Figure 29. Trip configuration 

 

 

Figure 30. Trip continuous distance counting parameter example 

Summary of Contents for FM3600

Page 1: ...FM3620 User Manual V1 5 ...

Page 2: ... ACCESSORIES 17 4 FIRMWARE 21 4 1 UPDATING FIRMWARE USING USB CABLE 21 5 OPERATIONAL BASICS 22 5 1 OPERATIONAL PRINCIPALS 22 5 2 SLEEP MODES 22 5 2 1 Sleep mode 22 5 2 2 Deep Sleep mode 23 5 3 VIRTUAL ODOMETER 23 5 4 FEATURES 24 5 4 1 Scenarios 24 5 4 2 Trip 25 5 4 3 Geofencing 25 5 4 4 iButton list 25 5 5 CONFIGURATION 25 5 6 CONFIGURATOR 25 5 7 READ RECORDS 27 5 8 SYSTEM SETTINGS 29 5 9 RECORDS ...

Page 3: ...D 1000 59 8 2 2 Sleep timeout ID 200 59 8 2 3 Analog Input value range ID 1001 59 8 2 4 Stop Detection Source ID 1002 59 8 2 5 Static Navigation ID 1003 60 8 2 6 Ignition Source ID 1004 60 8 2 7 GNSS FIX Timeout for Time Synchronization via NTP ID 1007 60 8 2 8 Saving Sending without time synchronization ID 201 60 8 2 9 GNSS System ID 202 60 8 3 RECORDS PARAMETERS 61 8 3 1 Sorting ID 1010 61 8 3 2...

Page 4: ...on list checking scenario ID 1608 73 8 6 10 Trip ID 1280 74 8 6 11 Start Speed ID 1281 74 8 6 12 Ignition Off Timeout ID 1282 75 8 6 13 Trip Continuous distance counting ID 1283 77 8 6 14 Geofencing 78 8 6 15 AutoGeofencing 80 8 6 16 iButton List ID 7000 7499 81 8 7 I O PARAMETERS 81 8 7 1 I O 1 Priority ID 2000 81 8 7 2 I O 1 High level ID 2001 81 8 7 3 I O 1 Low level ID 2002 82 8 7 4 I O 1 even...

Page 5: ...s not responsible for any harm caused by using wrong cables for PC FM3620 connection 1 2 Instructions of safety This chapter contains information on how to operate FM3620 safely By following these requirements and recommendations you will avoid dangerous situations You must read these instructions carefully and follow them strictly before operating the device The device uses a 10 V 30 V DC power s...

Page 6: ...ment This document contains information about the architecture possibilities mechanical characteristics and configuration of the FM3620 device Acronyms and terms used in document PC Personal Computer GPRS General Packet Radio Service GNSS Global Positioning System GSM Global System for Mobile Communications SMS Short Message Service AC DC Alternating Current Direct Current I O Input Output Record ...

Page 7: ...t power supply cable with a 2x3 connection pins GNSS antenna GSM 3G antenna USB cable Li Po battery 3 7 1800mAh A card which contains URL to download FM3620 device drivers and Configurator software 2 2 Basic characteristics GSM GPRS 3G features UMTS HSPA GSM GPRS EDGE module UMTS HSPA bands depending on module o HE910 D 850 900 1700 1900 2100 MHz o UE910 EUD 900 1800 900 2100 MHZ HSUPA rate up to ...

Page 8: ...r input speed temperature etc Highly configurable data acquisition and sending Multiple Geo fence areas Sleep mode Deep sleep mode Configurable scenarios available Real time process monitoring Authorized number list for remote access Firmware update over GPRS or USB port Configuration update over GPRS SMS or USB port TCP IP or UDP IP protocol support Up to 3584 records storing Radio frequency jamm...

Page 9: ...n temperature 25 C 55 C Storage temperature 40 C 70 C Storage relative humidity 5 95 no condensation System LED LED Navigation LED LED GNSS GNSS antenna connector MCX GSM 3G GSM 3G antenna connector SMA female outer shell female inner pin Socket 2x3 Tyco Micro MATE N LOK 4 794628 0 or similar USB Mini USB socket Table 1 FM3620 specifications 2 When in Sleep mode FM unit turns OFF GNSS module 3 Whe...

Page 10: ...10 Figure 1 FM3620 view dimensions tolerance 2mm ...

Page 11: ...0 mA Sleep average on 12V 23 mA Sleep average on 24V 8 9 mA Ucc 12V all modules fully working 700 mA Ucc 24V all modules fully working 330 mA Digital Input Input resistance DIN1 DIN2 15 kOhm Input Voltage Recommended Operating Conditions 0 Supply voltage V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Analog Input Input Voltage Recommended Operating Conditions Range1 0 10 V...

Page 12: ...imum Ratings 32 32 V Drain Source clamp threshold voltage Absolute Maximum Ratings Idrain 2mA 36 V Digital Input Voltage Absolute Maximum Ratings 32 32 V Analog Input Voltage Absolute Maximum Ratings 32 32 V 3 CONNECTION PINOUT ACCESSORIES 3 1 How to insert SIM card and attach battery into FM3620 device Gently open FM3620 case using screwdriver ...

Page 13: ...13 Remove FM3620 case Insert SIM card as shown Attach battery With screwdriver attach cover Attach top housing cover Device is ready ...

Page 14: ...avl1 teltonika lt downloads FM33 vcpdriver_v1 3 1_setup zip Installing drivers Extract and run VCPDriver_V1 3 1_Setup exe This driver is used to detect FM3620 device connected to the computer Click Next in driver installation window figures below Figure 2 Driver installation window This will launch device driver installation wizard In the following window click Next button again Figure 3 Driver in...

Page 15: ...S antenna short circuited 3 4 Modem LED Behavior Meaning Blinking every second Normal mode Blinking every 2 seconds Deep sleep mode Blinking fast for a short time Modem activity Blinking fast constantly Boot mode Off Device is not working Or Device firmware being flashed 3 5 Status LED Behavior Meaning Permanently off Device off Blinking every 1 second Net search Not registered turning off Slow bl...

Page 16: ...r 1 Wire devices max 20mA Table 2 Socket 2x3 pinout description digital input status 0 2 V FALSE 2 5 V 30 V TRUE The described PINOUT is used only for FM3620_C2 hardware configuration 3 7 FM3620_C1 Socket 2 3 Figure 5 2 3 socket pinout Pin Nr Pin Name Description 1 VCC 10 30 V DC Power supply for module Power supply range 10 30 V DC Energy consumption GPRS 200 mA r m s Max 2 DIN 1 AIN Digital inpu...

Page 17: ...r FM3620_C1 hardware configuration 3 8 USB Mini USB connector Figure 6 Mini USB type B connector FM3620 connected to PC creates an STM Virtual COM Port which can be used as a system port to flash firmware and configure the device Figure 7 COM Ports 3 9 Accessories 1 Wire devices for FM3620_C2 One of the realized features is 1 Wire data protocol which enables connection of thermometer DS1820 DS18S2...

Page 18: ...C power source for external digital sensor GND FM3620 pin4 3 2 Output from external digital sensor Digital Input 4 Figure 8 Digital thermometer DS1820 and TTJ100 connection scheme Figure 9 I Button DS1990A connection scheme Note Teltonika does not provide any additional equipment like panic buttons door sensors or others ...

Page 19: ...gure 10 shows the connection scheme to the FM3620 and fuel tank sensor through Analog input 1 After the connection to the tank fuel level sensor calibration is needed Calibration is needed because most fuel tank sensors are not linear Calibration is performed by measuring voltage dependence on volume of fuel in tank Figure 10 Fuel Tank sensor connection Alarm buttons door sensors etc Alarm buttons...

Page 20: ...ion Immobilizer relay When connected as shown below FM3620 disables engine starter when output is OFF More details about relays can be found below Figure 13 Immobilizer relay connection Relays An ordinary automotive relay is used to invert input signal or to immobilize engine starter Note that they are available as 12 V or 24 V Figure 14 Automotive relay pinout ...

Page 21: ...y one firmware must be in folder Connect FM3620 to PC with the USB cable Launch Firmware Updater select COM port to which device is connected click connect and when IMEI and Firmware version fields are filled start the update Device needs some time to send IMEI and Firmware version so do not be afraid if IMEI will not show up immediately disconnect and after 1 2 minutes try to connect again Update...

Page 22: ...de If 3G coverage is not available the device sends data through GPRS network FM3620 can also be configured to send data over GPRS and SMS only This mode can be used to save bills or in the areas where 3G is not available The least preferred data sending mode is SMS which is mostly used in areas without GPRS coverage or GPRS usage is too expensive 3G GPRS and SMS settings are described in further ...

Page 23: ...ut set Device must be synchronized time with GNSS satellites or via NTP No movement by motion sensor is detected Ignition DIN1 is off Min Record Saving Period Data Acquisition Mode settings must be bigger than Active Data Link Timeout parameter that FM3620 could close GPRS 3G link Send period Data Acquisition Mode settings minus Active Data Link Timeout must be more than 90 sec that FM3620 could c...

Page 24: ...on is ON DIN1 1 Vehicle speed is equal or higher than 10km h Harsh cornering is monitored only when following conditions are fulfilled Ignition is ON DIN1 1 Vehicle speed is equal or higher than 30km h Note Green Driving Scenario is a factor on various cars and various drivers testing phase and can be subject to changes Teltonika is constantly working on improvement of the functionality of the dev...

Page 25: ... information FM3620 configuration is performed via FM3620 Configurator program FM3620 Configurator version can be downloaded from http avl1 teltonika lt downloads FM36 Contact sales manager to get the latest FM3620 Configurator version FM3620 configurator operates on Microsoft Windows OS and uses MS Net Framework 3 5 or higher Please ensure that MS Net Framework 3 5 or later is installed on your P...

Page 26: ...is configuration mode it is only required to enter network parameters In Advanced Configuration mode FM3620 is more configurable Figure 18 Configurator window FM3620 Configurator is divided into main areas 1 main button area 2 information area 3 settings menu 4 parameters and values menu 5 recommended configuration values ...

Page 27: ... symbol length If keyword is set every time user reconnects FM3620 to USB port user will be asked to provide valid keyword when connecting FM3620 to configurator User is given 5 attempts to enter keyword After entering valid keyword counter resets to 5 If user disconnects FM3620 using Disconnect button and does not disconnect from USB port after reconnecting using Connect button configurator does ...

Page 28: ...VL Preview track of the imported data Generate reports of the imported data More details on how to use TAVL application please refer to TAVL3 application user manual v1 4 documentation or its later versions FM3620 version can be still used as a standard FM3620 It can be configured to acquire and send data to server It will be possible to store up to 3854 data records if GSM is not available at the...

Page 29: ...e Level the ignition is considered to be turned on o Digital Input DIN1 ON ignition on DIN1 OFF ignition off o Movement if accelerometer movement sensor detects movement then ignition is on if movement stops ignition is off Stop Detection Source Vehicle on Stop mode Vehicle Moving mode Ignition recommended If ignition configured Ignition Source is logic low If ignition configured Ignition Source i...

Page 30: ... Link Timeout is used to set timeout of link between FM3620 and AVL application termination If FM3620 has already sent all records it waits for new records before closing link If new records are generated in the period of this timeout and minimum count to send is reached they are sent to AVL application This option is useful when GSM operator charge for link activation Server Response Timeout is u...

Page 31: ...ord are not set in every SMS sent to FM3620 device two spaces before command have to be used space space command Command structure with set login and password login space password space command example opa opa getgps Phone numbers have to be written in international standard without using or 00 signs in prefix If no numbers are entered configuration and sending commands over SMS are allowed from a...

Page 32: ...FM3620 module from unauthorized access Module accepts messages only from a list of authorized numbers and with proper module login and password Numbers must be without or 00 prefix If no authorized numbers are entered module accepts messages from all numbers 5 12 GSM settings Operator list Operators list FM3620 can work in different modes use different settings according to the operator list defin...

Page 33: ...12 and are switched when GSM operator changes e g vehicle passes through country boarder If current GSM operator is defined as Home Operator device will work in Home Data Acquisition mode if current operator is defined as Roaming Operator device will work in Roaming Data Acquisition mode and if current operator code is not written in Operator list but there is at least one operator code in the ope...

Page 34: ... mode ONLY Figure 26 Data Acquisition Mode configuration Operator search is performed every 15 minutes Depending on current GSM operator Home Roaming or Unknown mode can be changed faster than every 15 minutes This process is separate from operator search Movement criteria are checked every second ...

Page 35: ...bytes kilobytes transmitted per session During the session FM3620 makes connection and transmits data to a server FM3620 tries to handle the session as much as possible it never closes session by itself Session can last for hours days weeks or session can be closed after every connection in certain GSM networks this depends on GSM network provider GPRS Context Week Time defines session re establis...

Page 36: ... than 10km h then FM3620 checks if angle difference between last record and current record is equal or higher than Angle based acquire value If so saves the record to memory These checks are performed every second Note Keep in mind that FM3620 operates in GMT 0 time zone without daylight saving FM3620 is able to collect records using four methods at the same time time distance angle and speed base...

Page 37: ...a acquisition depending on angle Min angle Speed based data acquiring Min speed delta records are being acquired when speed difference between last recorded coordinate and current position is greater than defined value Entering zero disables data acquisition depending on speed 5 14 Features settings For more information about available Scenarios Trip Geofencing and iButton list refer to 5 4 chapte...

Page 38: ... fixing radio frequency jamming After jamming is over DOUT1 is deactivated Authorized driving if selected DOUT2 DOUT2 is continuously OFF Dout2 turns ON if Ignition turns ON configured Ignition Source 1 After authorizing iButton iButton ID is read and it matches the ID from the iButton list DOUT2 turns OFF After successful authorization ignition can be turned OFF configured Ignition Source 0 for n...

Page 39: ...ce is going to be counted continuously from Trip start to Trip stop This value is written to I O Odometer value field When Trip is over and next Trip begins Odometer value is reset to zero When the next trip starts counting continuously starts from the beginning again If I O Odometer is enabled and Continuous Distance Counting variable is set Not then the distance is going to be counted only betwe...

Page 40: ...is considered to have entered the area while track 2 is not Track Nr 1 Track Nr 2 Figure 31 Geofence border Shape can be rectangle or circle Priority priority of Geofence event low high or panic These levels define priority of event information sending to server See I O element description for more details about priorities Generate event On entrance On exit On Both choose when record will be gener...

Page 41: ...ource becomes high it will disable AutoGeofenze Zone iButton if iButton is attached it will disable AutoGeofence Zone Edit iButton List if list is not empty attached iButton is tested against an iButton list if match is found AutoGeofence zone is disabled Priority Priority of generated event which will be applied to saved record Exit Event Event generation on Geofence exit On Both Event generation...

Page 42: ...ered This event can be triggered by Green Driving OverSpeeding Authorized Driving Immobilizer Trip start stop Geofence AutoGeofence I O event When any of the above events is triggered FM3620 sends a configured SMS message to a defined phone number If SMS events is activated but there are no numbers defined in SMS events PreDefined Numbers list figure 34 then the device will not send any messages ...

Page 43: ... EventText For example if FM3620 is configured to send an SMS figure 35 when Digital Input 1 reaches High level with priority High and configured to generate event on both range enter and exit figure36 then the sent SMS is 2012 6 7 12 00 00 Digital Input 1 Figure 35 Configured Digital Input 1 SMS Event ...

Page 44: ...mory until it wakes up from Deep Sleep mode and GSM modem starts working normally After it wakes up all the messages that are saved in memory will be sent but keep in mind that only 10 messages can be saved in memory all other messages will not be saved until there is room in device memory 5 14 4 1 SMS events configuration Scenarios To configure SMS events for scenarios open Scenarios window and E...

Page 45: ...ble Trip feature figure 39 Then go to GSM SMS SMS Events settings and Enable Trip SMS event After enabling SMS Events figure 43 trip event will be triggered and message sent when Trip starts GNSS speed exceeds the speed in Start Speed ex 5 km h and when Trip stops that is ignition is turned off longer then the time written in Ignition Off Timeout ex 60 seconds Figure 39 Trip Start Stop SMS event c...

Page 46: ...ne The Geofence zone must be configured to generate an event On Exit On Enter or On Both figure 41 If No Event is selected then it is not possible to turn on SMS events If several zones are created then SMS events can be turned on separately for each zone entering different text message Figure 41 Geofence SMS event configuration Figure 42 Geofence SMS event configuration ...

Page 47: ...43 AutoGeofence configuration Figure 44 AutoGeofence SMS event configuration I O events FM3620 sends SMS event message when a configured I O property enters and or exits its configured High Low boundaries or Hysteresis event generation is chosen Monitoring does not generate event so SMS event could not be configured Every IO element SMS event can be configured to send individual message to differe...

Page 48: ...put 1 Voltage mV 0 30 V 3 Digital Output 1 Logic 0 1 4 Digital Output 2 Logic 0 1 5 GNSS PDOP Probability 10 0 500 6 GNSS HDOP Probability 10 0 500 7 External Voltage Voltage mV 0 30 V 8 GNSS Power States 0 short circ 1 connected Parameter defines if GNSS antenna is short circuit All the time value will be sent 1 The only condition to get value 0 then antenna is damaged and short circuit Note if y...

Page 49: ...l I O elements generate and send record to server only if appropriate conditions are met Nr Property Name Description 26 Geofence zone 01 Event 0 target left zone 1 target entered zone 27 Geofence zone 02 Event 0 target left zone 1 target entered zone 28 Geofence zone 03 Event 0 target left zone 1 target entered zone 29 Geofence zone 04 Event 0 target left zone 1 target entered zone 30 Geofence zo...

Page 50: ...AVL packet priority can be low high or panic Regular packets are sent as Low priority records When low priority event is triggered FM3620 makes additional record with indication that the reason for that was I O element change When High priority is selected module makes additional record with high priority flag and sends event packet immediately to the server by GPRS Panic priority triggers same ac...

Page 51: ...ettings Setting Value Priority low high High level maximum threshold Low level minimum threshold Generate event on interval enter on interval exit on both enter and exit Average constant 1 232 4 Bytes Figure 49 Digital Input event generation example 5 15 3 Hysteresis Figure 50 Hysteresis parameter configuration Note I O element s Movement sensor Averaging constant is interpreted as Start Move Time...

Page 52: ...sleep mode 6 1 SMS command list Command Description Response getstatus Modem Status information Yes getweektime Current device time Day of Week and amount of minutes passed since start of week Yes getops List of currently available GSM operator Yes getcfgtime Date and Time of last successful configuration Yes ggps Google Map Link information Yes getgps Current GPS data and time Yes cpureset Reset ...

Page 53: ...CAN info by SMS Yes 6 1 1 getstatus Response details Description Data Link Indicate module connection to server at the moment 0 Not connected 1 connected GPRS Indicate if GPRS is available at the moment Phone Voice Call status 0 ready 1 unavailable 2 unknown 3 ringing 4 call in progress 5 asleep SIM SIM Status 0 ready 1 pin 2 puk 3 pin2 4 puk2 OP Connected to GSM Operator numerical id of operator ...

Page 54: ...e Example Last Configuration was performed on 2010 4 15 5 45 19 6 1 5 getgps Response details Description Gps Indicates valid 1 or invalid 0 Gps data Sat Count of currently available satellites Lat Latitude Last good Latitude Long Longitude Last good Longitude Alt Altitude Speed Ground speed km h Dir Ground direction degrees Date Current date Time Current GMT time Example GPS 1 Sat 7 Lat 54 71473 ...

Page 55: ...umber of broken records CF Profile CRC Fail counter FG Failed GPRS counter FL Failed link counter UT UPD Timeout counter SMS Sent SMS Counter NOGPS No GPS Timer GPS GPS receiver state 0 OFF 1 restarting 2 ON but no fix 3 ON and operational 4 sleep mode SAT Average satellites RS Reset Source Identification 1 Low Power 2 W Watchdog 3 I Watchdog 4 Software reset 5 Power On 6 Pin Reset MD Data Mode st...

Page 56: ...be found in chapter number 8 Parameter List Example setparam 1245 127 0 0 1 will change configured IP address 6 1 13 getparam 1271 X 212 X X values can be 1 2 3 If X 1 Operator codes from 0 19 are read from configuration and sent via SMS If X 2 Operator codes from 20 39 are read from configuration and sent via SMS If X 3 Operator codes from 40 49 are read from configuration and sent via SMS If X a...

Page 57: ...isabled 1 enabled Time Sync Indicates time synchronization on the device 0 not synchronized 1 synchronized Example FLUSH SMS Accepted 11 records found on FLASH Minimum Records to Send 1 GPRS Enabled 1 Time Sync 1 6 1 17 sn Enables or disables Static navigation 1 enable 0 disable 6 1 18 banlist Gives a list of all banned operators Example when no operators are banned 0000 00s 0 000 6 1 19 crashlog ...

Page 58: ... information to possible solutions when operating as unexpected Download Terminal from http avl1 teltonika lt Downloads Software Terminal zip After launching terminal choose baud rate 115200 and hardware control none Select COM port which is assigned to Virtual COM Port Click on Start Log button and save a new file Then click Connect to start receiving messages from FM3620 Also you can log NMEA da...

Page 59: ...ue Recommended value Goes with depends on parameters Value type 0 2 U8 8 2 2 Sleep timeout ID 200 Sleep timeout is time after which FM3620 goes to sleep or deep sleep if other requirements are met It is measured in minutes Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 3000 U8 8 2 3 Analog Input value range ID 1001 Analog input measuring resolution and r...

Page 60: ...eout is set too 60s default value and during this time GPS FIX is received use default GNSS time synchronization method However if the GPS time FIX is not received a FM is going to get time using NTP server Device will activate GPRS context and create UDP connection to destination port 123 using SNTP protocol Minimum value Maximum value Recommended value Goes with depends on parameters Value type ...

Page 61: ... an active data link if the device doesn t send any data for a very long time even if active data link timeout is set to maximum value The amount of time that an operator keeps the link open depends solely on the operator For example if active data link timeout is set to maximum 259200 seconds 72 hours and the device sends data to server every 86400 seconds 24 hours the operator might disconnect t...

Page 62: ...sword ID 1244 Parameter defines APN password In case operator does not use password for login value should be empty Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 30 char string GPRS content activation ID 1240 APN Name ID 1242 APN username ID 1243 S8 30 8 4 5 Domain ID 1245 Parameter defines AVL data destination server IP address Example 212 47 99 62...

Page 63: ...GPRS content activation ID 1240 U8 8 4 9 SMS Login ID 1252 User login is used to ensure module security Used in every SMS that is sent to device Example ba321 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char SMS Password ID 1253 S8 5 8 4 10 SMS Password ID 1253 User password is used to ensure module security Used in every SMS that is sent to dev...

Page 64: ...ecommended value Goes with depends on parameters Value type 1 digit 16 digits S8 17 If SMS data sending is enabled ID 1250 first value in a list is server GSM number The SMS with 24 coordinates is sent to this number Deleting Authorized phone numbers do no write any value is configuration SMS command Example setparam 1260 8 4 15 SMS Event PreDefined Numbers ID 150 159 In this field are written GSM...

Page 65: ...0 Min Saved Records ID 1543 GPRS Week Time ID 1545 U32 8 5 1 4 GPRS Week Time ID 1545 This parameter manages when it is allowed to open GPRS context When module starts it is prohibited to open the context When modem s GPRS context is closing for example changing network it is allowed to open it only at a defined time It is possible to allow connections every 10 minutes up to once per day Example v...

Page 66: ...s is greater than parameters value If value is 0 it means no records by min distance will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 Min Period ID 1550 Min Angle ID 1552 Min Speed ID 1556 GPRS Week Time ID 1555 U32 8 5 2 3 Min Angle ID 1552 This parameter indicates angle in degrees in order to acquire new record If angle difference bet...

Page 67: ...ime ID 1555 U8 8 5 2 7 Send Period ID 1554 This parameter indicates frequency time interval in seconds of sending data to server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 GPRS Week Time ID 1555 U32 8 5 2 8 GPRS Week Time ID 1555 Read 8 5 1 4 8 5 3 Roaming Network GSM operator code Vehicle on STOP parameters 8 5 3 1 Min Period ID 1560 This pa...

Page 68: ...Distance ID 1571 This parameter indicates distance in meters in order to acquire new record Record is stored when the distance between previous records is greater than parameter s value If value is 0 it means no records by min distance will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 Min Period ID 1570 Min Angle ID 1572 Min Speed ID 157...

Page 69: ...d ID 1576 GPRS Week Time ID 1575 U8 8 5 4 6 Min Saved Records ID 1573 This parameter defines minimum number of records in one data packet that can be sent to server It has higher priority than Data Send Period ID 1574 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 Min Period ID 1570 Min Distance ID 1571 Min Angle ID 1572 Min Speed ID 1576 GPRS Week...

Page 70: ...5 Read chapter 8 5 1 4 8 5 6 Unknown Network GSM operator code Vehicle MOVING parameters 8 5 6 1 Min Period ID 1590 This parameter indicates time interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Distance ID 1591 Min Angle ID 1592 Min...

Page 71: ...f value is 0 it means no records by min distance will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 255 1 Min Period ID 1590 Min Distance ID 1591 Min Angle ID 1592 Min Speed Source ID 1597 GPRS Week Time ID 1595 U16 8 5 6 5 Min Speed Source ID 1597 This parameter defines Source for speed difference calculation 0 GPS 1 LVCAN Minimum value Maximu...

Page 72: ...oes with depends on parameters Value type 0 3 0 U8 8 6 2 Max Acceleration Force ID 1602 It is max allowed acceleration force which can be reached while accelerating without triggering harsh acceleration event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25 0 85 0 25 Green Driving scenario ID 1600 Float 8 6 3 Max Braking Force ID 1603 It is max allowed ...

Page 73: ...o can be enabled to work with 3 different ways Dout not control scenario value 1 Dout1 controls scenario value 2 Dout2 controls scenario value 3 To disable Jamming detection scenario value 0 is used Minimum value Maximum value Default value Goes with depends on parameters Value type 0 3 0 U8 8 6 8 Immobilizer scenario ID 1607 Immobilizer detection scenario can be enabled to work with 3 different w...

Page 74: ... be enabled to work with 3 different ways Dout not control scenario value 1 Dout1 controls scenario value 2 Dout2 controls scenario value 3 To disable OverSpeeding scenario value 0 is used Minimum value Maximum value Default value Goes with param 0 3 0 8 6 12 Jamming detection scenario ID 1606 Jamming detection scenario can be enabled to work with 3 different ways Dout not control scenario value 1...

Page 75: ... Default value Goes with param 0 3 0 Trip ID 1280 8 6 15 Ignition Off Timeout ID 1282 This parameter represents timeout to wait if ignition is off in order to detect TRIP STOP and generate event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 OverSpeeding scenario ID 1601 OverSpeeding scenario can be enabled to work with 3 different ways Dout not co...

Page 76: ...6 17 Immobilizer scenario ID 1607 Immobilizer detection scenario can be enabled to work with 3 different ways Dout not control scenario value 1 Dout1 controls scenario value 2 Dout2 controls scenario value 3 To disable Immobilizer detection scenario value 0 is used Minimum value Maximum value Default value Goes with param 0 3 0 8 6 18 iButton list checking scenario ID 1608 iButton list checking de...

Page 77: ...t1 controls scenario value 2 Dout2 controls scenario value 3 To disable OverSpeeding scenario value 0 is used Minimum value Maximum value Default value Goes with param 0 3 0 8 6 20 Jamming detection scenario ID 1606 Jamming detection scenario can be enabled to work with 3 different ways Dout not control scenario value 1 Dout1 controls scenario value 2 Dout2 controls scenario value 3 To disable Jam...

Page 78: ...rt 8 6 10 is presented a table with the IDs of all the rest Geofence zones 8 6 23 1 Frame border ID 1020 Geofence border thickness measured in meters Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1000000 1000 All Geofencing parameters U32 8 6 23 2 Geofence Zone 1 Shape ID 1030 Geofence shape parameter can be circle value 0 rectangle value 1 Minimum valu...

Page 79: ...528 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 180 180 All Geofencing parameters Float 8 6 23 6 Geofence Zone 1 Latitude Y1 ID 1034 Parameter has two meanings dependent on zone shape If shape is a rectangle then ID 1034 is left down corner Y coordinate If shape is a circle then ID 1034 is center of that circle Y coordinate Minimum value Maximum value R...

Page 80: ...ers have the same logic as shown in GeoFence Zone 1 GeoFence Zone Number Geofence Zone s parameters 1 1030 1036 2 1040 1046 3 1050 1056 4 1060 1066 5 1070 1076 8 6 24 AutoGeofencing 8 6 24 1 Activation Timeout ID 1102 Parameter represents AutoGeofencing activation timeout in seconds Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 60 Priority ID 1103...

Page 81: ... ID 1103 Deactivate by ID 1100 U32 8 6 25 iButton List ID 7000 7499 Read 5 4 4 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 FFFFFFFF FFFFFFFF iButtons list checking ID 1608 Deactivate by ID 1100 U64 8 7 I O parameters I O properties are additional data sources which are recorded along with usual GPS data 8 7 1 I O 1 Priority ID 2000 Parameter defines I...

Page 82: ...32 8 7 4 I O 1 event generation type ID 2003 Parameter defines when event is sent 0 on range exit 1 on range entrance 2 both 3 monitoring 4 hysteresis 5 on changes Minimal value Maximum value Recommended value Goes with depends on parameters Value type 0 4 3 I O 1 Priority ID 2000 I O 1 High level ID 2001 I O 1 Low level ID 2002 I O 1 averaging length ID 2004 S8 8 7 5 I O 1 averaging length ID 200...

Page 83: ... Value 2100 2104 I O 11 GSM Operator 2110 2114 I O 12 Speed Km h 2120 2124 I O 13 iButton ID 2130 2134 I O 14 Mode 2140 2144 I O 15 GSM Signal 2150 2154 I O 16 Deep Sleep 2160 2164 I O 17 Cell ID 2170 2174 I O 18 Area Code 2180 2184 I O 19 Dallas Temperature 1 2190 2194 I O 20 Dallas Temperature 2 2200 2204 I O 21 Dallas Temperature 3 2210 2214 I O 22 Battery Voltage 2220 2224 I O 23 Battery Charg...

Page 84: ... event IDs are listed in the next table Element name default SMS Event Text ID Digital input 1 5100 Digital input 2 5101 Analog Input 1 5102 Digital Output 1 5103 Digital Output 2 5104 GNSS PDOP 5105 GNSS HDOP 5106 External Voltage 5107 GNSS Power 5108 Movement Sensor 5109 Odometer Value 5110 GSM Operator 5111 Speed 5112 iButton ID 5113 Data Mode 5114 GSM Signal 5115 Deep Sleep 5116 Cell ID 5117 A...

Page 85: ...gricultural Machinery Flags 5153 LVC Harvesting Time 5154 LVC Area of Harvest 5155 LVC Mowing Efficiency 5156 LVC Grain Mown Volume 5157 LVC Grain Moisture 5158 LVC Harvesting Drum RPM 5159 LVC Gap Under Harvesting Drum 5160 LVC Security State Flags 5161 LVC Tacho Total Vehicle Distance 5162 LVC Trip Distance 5163 LVC Tacho Vehicle Speed 5164 LVC Tacho Driver Card Presence 5165 LVC Driver1 States ...

Page 86: ... Vehicles Can adapter LV CAN200 9 1 Purpose of Light Vehicles Can Adapter LV CAN200 LV CAN200 is used to listening data from light vehicles With this adapter FM3620 device is able to collect and send vehicle data Figure 53 connection block diagram FM3620 shares the same USB port for connecting adapter and configuring device with PC LV CAN200 Technical characteristics PARAMETER VALUE Supply voltage...

Page 87: ...nd LV CAN200 program number can be set remotely using SMS command lvcansetprog X X is new program number value 9 2 2 Selecting LV CAN200 program number manually Steps to set program number Hold SWITCH down till LED stars blinking Release the SWITCH Then LED starts blinking and counting first digit of program number one blink means digit 1 two blink digit 2 etc To stop counter push SWITCH Release t...

Page 88: ...nnect Light Vehicles Can adapter Pin 1 and Pin 2 to cars CAN bus CAN interface location of the supported light vehicle is described on mounting scheme Connect car power supply lines to Pin 3 positive Pin 4 Negative Pins 9 10 connection is optional it depends on exact car model For exact pinout see sticker on Light Vehicles Can adapter Figure 55 LV CAN200 Adapter connection cable pinout ...

Page 89: ...PC USB cable to FM3620 Device Figure 57 It is very important not to disconnect FM3620 from power source during this operation because if FM3620 is reconnected all received CAN bus data will be lost FM3620 remembers received data from LV CAN200 and at the end of the procedure when SCAN button is pressed user will see all CAN data which is sent by adapter Enable CAN data which needs send to server a...

Page 90: ...t to the server By default all CAN elements are disabled and FM3620 records only GPS data It is possible to set CAN message priority On Low Priority On High Priority and On Panic Regular packets are sent as Low priority records When low priority event is triggered FM3620 makes additional record with indication what was the reason for that was CAN element change When High priority is selected modul...

Page 91: ... Table 9 1 ACQUIRED PARAMETRS IO ID Category name signal name Size Bytes Param IO ID Value range 65265 Cruise Control Vehicle Speed Vehicle Speed 1 2290 0 250 km h 61443 Electronic Engine Controller 2 Accelerator Pedal Position 1 2300 0 100 65257 Fuel Consumption Total Fuel Used 4 2310 0 99999999liters 65276 Dash Display Fuel Level liters 2 2320 0 100 liters 61444 Electronic Engine Controller 1 En...

Page 92: ...l level liters 2320 2324 Engine RPM 2330 2334 Vehicle distance 2340 2343 Fuel level proc 2350 2354 Program number 2360 2363 Table 9 3 LV CAN200 IO parameters configuration Parameter ID Parameter name Available values 2xx0 Priority 0 IO element disabled 1 Low priority 1 High priority 3 Panic priority 2xx1 Generation type 0 Event on exit 1 Event on entrance 2 Event on both 3 Monitoring 4 Hysteresis ...

Page 93: ...btained via SMS SMS Text lvcangetprog Response CAN Program Nr XXX 9 7 Get LV CAN info by SMS Full LV CAN information via SMS SMS Text lvcangetinfo Response Prog 139 SWRevison 6 KernVer 10 KernVar 49 MdlID 8884443332221110 9 8 References 1 Light Vehicles Can adapter LV CAN200 Supported cars 2 Cars mounting scheme ...

Page 94: ...e first position most electronics of the vehicle are available Check if power is still available when you turn off any of vehicles devices Ignition is connected to the ignition relay output As alternative any other relay which has power output when ignition is on may be chosen 9 12 Connecting Ground Wire Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame If th...

Page 95: ...ees GNSS antenna must be placed sticker facing down Figure 59 Correct GNSS antenna mounting It is recommended to place GNSS antenna behind dashboard as close to the window as possible A good example of GNSS antenna placement is displayed in a picture below area colored green Figure 60 Correct placement of FM3620 9 14 Module Installation Module should not be seen or easily reached Module should be ...

Page 96: ...Priority Geofence Priority Event Generation parameters Fixed LVCAN Param ID Fixed IO Priority values 3 2016 02 02 1 3 Minor correction 4 2016 02 09 1 4 DIN1 number correction in C2 hardware modification pinouts description 5 2016 02 09 1 5 DIN1 and DIN2 placement correction in C1 hardware modification pinouts description ...

Reviews: