38
Figure 28. Scenarios configuration
Digital Output (open drain grade) usage in scenarios:
Green Driving
DOUT1 is ON (if selected DOUT1) for:
3sec. if detected value is over (0; 30] % from preconfigured allowed value
5sec. if detected value is over (30; 50] % from preconfigured allowed value
7sec. if detected value is over (50; -] % from preconfigured allowed value
After period of time DOUT1 is turned OFF.
Over Speeding
DOUT1 is ON(if selected DOUT1), while vehicle speed exceeds parameter value. DOUT1 is
activated until current speed decreases below parameter value.
Jamming detection (if selected DOUT1)
DOUT1 is ON, while modem is fixing radio frequency jamming. After jamming is over,
DOUT1 is deactivated.
Authorized driving (if selected DOUT2)
DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (configured Ignition Source
=1). After authorizing iButton (iButton ID is read and it matches the ID from the iButton list),
DOUT2 turns OFF. After successful authorization ignition can be turned OFF (configured Ignition
Source =0) for no longer than 30 seconds, otherwise authorization must be repeated.
Immobilizer (if selected DOUT2)
DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (configured Ignition Source
=1). After iButton ID is read (any iButton is attached), DOUT2 turns OFF. After iButton
identification, ignition can be turned OFF (configured Ignition Source =0) for no longer than 30
seconds, otherwise immobilizer must be repeated.