background image

 

 

 

 

 

 

 

 

Optional features (enable with FM1100M): 

 

The memory can save up to 100,350 records;  

 

Offline working mode; 

 

Records exporting using USB; 

 

Optional feature (enable with 2SIM): 

 

•  2SIM cards features (slot 1 for SIM 1 is default);  
•  Including all FM1100M features. 

 

 

2.3

 

Technical features 

 

Part name 

Physical specification 

 

Technical details 

Navigation LED 

LED 

 

Power supply 10...30 V DC  

2W Max 

Energy consumption: 

GPRS: 

 150 mA r.m.s Max., 

Nominal: 

 average 65 mA r.m.s, 

GPS Sleep:  

 average 28 mA, 

Deep Sleep: 

 average

 

less than 

2 mA

2

 

Operation temperature:  

-25⁰C ... +55⁰C 

Storage temperature:  

-40⁰C ... +70⁰C 

Storage relative humidity 5 ... 95 % (no 

condensation) 

Modem LED 

LED 

 

GPS 

GPS antenna connector MCX 

 

GSM 

GSM antenna connector SMA 

female outer shell, female inner 

pin 

 

Socket 2x5 

Tyco Micro MATE-N-LOK™  

4-794628-0 or similar 

 

USB 

Mini USB socket 

 

Table 1. FM1100 specifications 

 

                                                      

2

 When in Deep Sleep mode no data storing and sending is activated. 

Summary of Contents for FM1100

Page 1: ...FM1100 User Manual v1 31 ...

Page 2: ...DATING FIRMWARE VIA GPRS 21 5 OPERATIONAL BASICS 21 5 1 OPERATIONAL PRINCIPALS 21 5 2 SLEEP MODES 22 5 2 1 Sleep mode 22 5 2 2 Deep Sleep mode 22 5 3 VIRTUAL ODOMETER 23 5 4 FEATURES 23 5 4 1 Scenarios 23 5 4 2 Trip 24 5 4 3 Geofencing 24 5 4 4 iButton list 25 5 5 CONFIGURATION 26 5 6 CONFIGURATOR 26 5 7 READ RECORDS 27 5 8 TWO SIM CARDS 28 5 8 1 Operator List 30 5 8 2 Preferred Roaming Operator L...

Page 3: ...R LIST 57 8 1 PARAMETERS VALUE TYPES 57 8 2 SYSTEM PARAMETERS 58 8 2 1 Sleep Mode ID 1000 58 8 2 2 Sleep timeout ID 200 58 8 2 3 Analog Input value range ID 1001 58 8 2 4 Stop Detection Source ID 1002 58 8 2 5 Static Navigation ID 1003 58 8 2 6 Saving Sending without time synchronization ID 201 59 8 3 RECORDS PARAMETERS 59 8 3 1 Sorting ID 1010 59 8 3 2 Active Data Link Timeout ID 1011 59 8 3 3 Se...

Page 4: ... Roaming Network GSM operator code Vehicle MOVING parameters 67 8 5 4 1 Min Period ID 1570 67 8 5 4 2 Min Distance ID 1571 67 8 5 4 3 Min Angle ID 1572 67 8 5 4 4 Min Saved Records ID 1573 67 8 5 4 5 Send Period ID 1574 67 8 5 4 6 GPRS Week Time ID 1575 68 8 5 5 Unknown Network GSM operator code Vehicle on STOP parameters 68 8 5 5 1 Min Period ID 1580 68 8 5 5 2 Min Saved Records ID 1583 68 8 5 5 ...

Page 5: ...Geofence event generating ID 1104 74 8 6 11 6 Radius ID 1105 74 8 6 12 iButton List ID 1610 1659 74 8 7 I O PARAMETERS 74 8 7 1 I O 1 property parameter ID 1300 74 8 7 2 I O 1 priority ID 1301 75 8 7 3 I O 1 High level ID 1302 75 8 7 4 I O 1 Low level ID 1303 75 8 7 5 I O 1 logic operand ID 1304 75 8 7 6 I O 1 averaging length ID 1305 76 8 8 SMS EVENT CONFIGURATION 77 8 8 1 I O 1 element SMS event...

Page 6: ...s not responsible for any harm caused by using wrong cables for PC FM1100 connection 1 2 Instructions of safety This chapter contains information on how to operate FM1100 safely By following these requirements and recommendations you will avoid dangerous situations You must read these instructions carefully and follow them strictly before operating the device The device uses a 10 V 30 V DC power s...

Page 7: ...eral Packet Radio Service GPS Global Positioning System GSM Global System for Mobile Communications SMS Short Message Service AC DC Alternating Current Direct Current I O Input Output Record AVL data stored in FM1100 memory AVL data contains GPS and I O information AVL packet data packet that is being sent to server during data transmission AVL packet contains from 1 to 50 records 2 BASIC DESCRIPT...

Page 8: ...or 1 MB internal Flash memory 16 MB optional Built in movement sensor Interface features Power supply 10 30V USB port 3 digital inputs 1 analog input 2 open collector digital outputs 1Wire temperature sensor 1Wire iButton LEDs indicating device status Special features Any element event triggers external sensor input speed temperature etc Highly configurable data acquisition and sending Multiple Ge...

Page 9: ...ower supply 10 30 V DC 2W Max Energy consumption GPRS 150 mA r m s Max Nominal average 65 mA r m s GPS Sleep average 28 mA Deep Sleep average less than 2 mA2 Operation temperature 25 C 55 C Storage temperature 40 C 70 C Storage relative humidity 5 95 no condensation Modem LED LED GPS GPS antenna connector MCX GSM GSM antenna connector SMA female outer shell female inner pin Socket 2x5 Tyco Micro M...

Page 10: ...10 Figure 1 FM1100 view dimensions tolerance 2mm ...

Page 11: ...nditions 0 Supply voltage V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 DIN3 2 5 V Analog Input Input Voltage Recommended Operating Conditions Range1 0 10 V Input resistance Range1 120 kOhm Measurement error 1 43 Additional error 12 mV Input Voltage Recommended Operating Conditions Range2 0 30 V Input resistance Range2 146 7 kOhm Measurement error 1 75 Additional error 36 mV Ou...

Page 12: ...lute Maximum Ratings VALUE CHARACTERISTIC DESCRIPTION Min Typ Max Unit Supply Voltage Absolute Maximum Ratings 32 32 V Drain Source clamp threshold voltage Absolute Maximum Ratings Idrain 2mA 36 V Digital Input Voltage Absolute Maximum Ratings 32 32 V Analog Input Voltage Absolute Maximum Ratings 32 32 V 3 CONNECTION PINOUT ACCESSORIES 3 1 How to insert SIM card into FM1100 device Gently open FM11...

Page 13: ...13 Remove FM1100 case Insert SIM card as shown Step for FM1100M 2SIM version Insert SIM cards as shown Lower slot is for SIM 1 upper slot is for SIM2 Attach top housing cover Device is ready ...

Page 14: ...avl1 teltonika lt downloads FM11 vcpdriver_v1 3 1_setup zip Installing drivers Extract and run VCPDriver_V1 3 1_Setup exe This driver is used to detect FM1100 device connected to the computer Click Next in driver installation window figures below Figure 2 Driver installation window This will launch device driver installation wizard In the following window click Next button again Figure 3 Driver in...

Page 15: ...use Deep sleep mode Or GPS antenna short circuited 3 4 Status LED Behaviour Meaning Blinking every second Normal mode Blinking every 2 seconds Deep sleep mode Blinking fast for a short time Modem activity Blinking fast constantly Boot mode Off Device is not working Or Device firmware being flashed 3 5 Socket 2 5 DIN 1 IGNITION 5 10 Ucc_DALLAS DIN 2 4 9 DIN 3 OUT 1 3 8 DATA_DALLAS OUT 2 2 7 AIN 1 V...

Page 16: ...R IGNITION INPUT 6 GND VCC 10 30 V DC Ground pin 10 30 V DC 7 AIN 1 Analog input channel 1 Input range 0 30V 0 10V DC 8 DATA_DALLAS Data channel for Dallas 1 Wire devices 9 DIN 3 Digital input channel 3 10 Ucc_DALLAS 3 8 V output for Dallas 1 Wire devices max 20mA Table 2 Socket 2x5 pinout description 3 6 USB Mini USB connector Figure 6 Mini USB type B connector FM1100 connected to PC creates an S...

Page 17: ...ermometer DS1820 DS18S20 and DS18B20 and I Button type DS1990A Figures 8 and 9 show FM1100 and 1 wire device connection schemes Left row of pins 1 3 4 1 2 2 J1 J2 J3 U1 Right row of pins 1W PWR FM1100 pin10 1 1W Data FM1100 pin8 2 1 Vpp 5 Volts DC power source for external digital sensor GND FM1100 pin6 3 2 Output from external digital sensor Digital Input 4 Figure 8 Digital thermometer DS1820 and...

Page 18: ...uel level sensor calibration is needed Calibration is needed because most fuel tank sensors are not linear Calibration is performed by measuring voltage dependence on volume of fuel in tank Alarm buttons door sensors etc Alarm buttons door sensors ignition etc return two states high or low voltage Digital inputs are used to read this information Figure below shows how to connect alarm button door ...

Page 19: ...t input signal or to immobilize engine starter Note that they are available as 12 V or 24 V Figure 14 Automotive relay pinout 4 FIRMWARE 4 1 Updating firmware using USB cable FM1100 functionality is always improving new firmware versions are developed Current module firmware version can be retrieved from Configurator See configuration description for details Contact sales manager to get the latest...

Page 20: ...are filled start the update Device needs some time to send IMEI and Firmware version so do not be afraid if IMEI will not show up immediately disconnect and after 1 2 minutes try to connect again Update process may take up to several minutes Figure 15 FM1100 firmware updater screen Figure 16 FM1100 firmware updating finished When you see a table like in Figure 15 it means that the firmware is flas...

Page 21: ...ways use this IP Server port 5009 always the same Always use this port Module number is GSM number of SIM card in worldwide standard for example 37069912345 Enter your APN APN chap login and password After entering all parameters click Add Module To operate multiple devices enter new IMEI and GSM number and click Add Module again Otherwise click Next and if all data is correct in next window click...

Page 22: ... Sleep mode and Sleep timeout is reached Device must be synchronized time with GPS satellites No movement by movement sensor is detected Ignition DIN1 is off FM1100 exits sleep mode when if ONE of following conditions are true Movement by movement sensor is detected Ignition DIN1 is turned on 5 2 2 Deep Sleep mode While in deep sleep mode FM1100 sets GPS receiver to sleep mode and turns off GSM GP...

Page 23: ...ent can be also used with Trip feature read chapters 5 4 2 and 5 15 2 for more details 5 4 Features Using available features can greatly increase FM1100 usability options 5 4 1 Scenarios Four scenarios are available on FM1100 device Digital Output No 1 is used by scenarios Green Driving or Over Speeding Digital Output No 2 is used by scenarios Authorized Driving or Immobilizer Green Driving Scenar...

Page 24: ... etc 5 4 2 Trip Trip customizable feature enables user extended monitoring of performed trips from engine start at present location to engine stop at arrived location log their start and stop points view driven total distance4 Event will be generated included into send records only when trip starts and finishes Note Scenarios and Trip features are activated DOUTs are activated only if DIN1 1 ignit...

Page 25: ...25 5 4 4 iButton list iButton list is used to enter authorized iButton ID codes which are used to authenticate driver in Authorized driving and Auto Geofencing options ...

Page 26: ...rocess starts from starting FM1100 Configurator program and then connecting to FM1100 device via Connect button located on the top left corner of configurator If connected successfully IMEI Version fields which were empty now are filled with certain numbers depending on Modem IMEI and firmware version of your device figure below FM1100 has one user editable profile which can be loaded from device ...

Page 27: ... valid keyword when connecting FM1100 to configurator User is given 5 attempts to enter keyword After entering valid keyword counter resets to 5 If user disconnects FM1100 using Disconnect button and does not disconnect from USB port after reconnecting using Connect button configurator does not ask for keyword ATTENTION If you have entered a keyword disconnected from the configurator and then late...

Page 28: ...on how to use TAVL application please refer to TAVL3 application user manual v1 4 documentation or its later versions FM1100M version can be still used as a standard FM1100 It can be configured to acquire and send data to server It will be possible to store up to 100 000 data records if GSM is not available at the moment It will send data later when GPRS is available again Note that FM1100M can ha...

Page 29: ...d in SIM1 slot default lower slot in SIMholder it is closer to PCB When FM1100 connected to configurator select in GSM Operator List section as shown on the Figure 22 FM11XX Configurator window 2SIM mode setup There is Operator List for SIM1 and SIM2 and Preferred Roaming Operator List for SIM1 and SIM2 Figure 22 FM11XX Configurator window 2SIM mode setup ...

Page 30: ...aming Operator Lists Higher placed operator in the operators list has higher priority If there are no available operators from SIM1 or SIM2 Operator lists or the lists are empty FM1100 scans the network and tries to connect Unknown operator If the connection is lost FM1100 will return to Home and try to connect to Home operators as it has the highest priority FM1100 every 15 min checks a possibili...

Page 31: ...31 Figure 23 Dual SIM connection algorithm ...

Page 32: ... Internal movement sensor detects movement GPS GPS fix is available and vehicle speed is lower than 5 km h GPS fix is available and vehicle speed is higher than 5 km h While GPS fix is unavailable Object Motion Detection Settings are working like in Msensor mode Static Navigation Mode is a filter which filters out track jumps when the object is stationary If Static navigation filter is disabled it...

Page 33: ...ers TCP or UDP Some operators use specific authentication for GPRS session CHAP or PAP If any of these is used APN should be entered as chap APN or pap APN I e if operator is using APN internet with CHAP authentication it should be entered as chap internet Information about APN and authentication type should be provided by your GSM operator Figure 26 GPRS configuration 5 12 GSM settings SMS part E...

Page 34: ...binary SMS to a phone number which is a server phone number the server can interpret and understand binary code so the data can be read and you can view it on the server SMS login and password and authorized number list are used to protect FM1100 module from unauthorized access Module accepts messages only from a list of authorized numbers and with proper module login and password Numbers must be ...

Page 35: ...hrough country boarder If current GSM operator is defined as Home Operator device will work in Home Data Acquisition mode if current operator is defined as Roaming Operator device will work in Roaming Data Acquisition mode and if current operator code is not written in Operator list but there is at least one operator code in the operator list device will work in Unknown Acquisition mode This funct...

Page 36: ... performed every 15 minutes Depending on current GSM operator Home Roaming or Unknown mode can be changed faster than every 15 minutes This process is separate from operator search Movement criteria are checked every second Figure 30 Data Acquisition Mode configuration ...

Page 37: ...smitted per session During the session FM1100 makes connection and transmits data to a server FM1100 tries to handle the session as much as possible it never closes session by itself Session can last for hours days weeks or session can be closed after every connection in certain GSM networks this depends on GSM network provider GPRS Context Week Time defines session re establish schedule if sessio...

Page 38: ... without daylight saving FM1100 is able to collect records using three methods at the same time time distance and angle based data acquisition Time based data acquiring Min period records are being acquired every time when defined interval of time passes Entering zero disables data acquisition depending on time Min time period Distance based data acquiring Min distance records are being acquired w...

Page 39: ...owed value 7sec if detected value is over 50 from preconfigured allowed value After period of time DOUT1 is turned OFF Over Speeding DOUT1 is ON while vehicle speed exceeds parameter value DOUT1 is activated until current speed decreases below parameter value Authorized driving DOUT2 is continuously OFF Dout2 turns ON if Ignition turns ON Din1 1 After authorizing iButton iButton ID is read and it ...

Page 40: ...s Trip distance is going to be counted continuously from Trip start to Trip stop This value is written to I O Odometer value field When Trip is over and next Trip begins Odometer value is reset to zero When the next trip starts counting continuously starts from the beginning again If I O Odometer is enabled and Continuous Distance Counting variable is set Not then the distance is going to be count...

Page 41: ...is considered to have entered the area while track 2 is not Track Nr 1 Track Nr 2 Figure 36 Geofence border Shape can be rectangle or circle Priority priority of Geofence event low high or panic These levels define priority of event information sending to server See I O element description for more details about priorities Generate event On entrance On exit On Both choose when record will be gener...

Page 42: ...becomes high it will disable AutoGeofenze Zone iButton if iButton is attached it will disable AutoGeofence Zone Edit iButton List if list is not empty attached iButton is tested against an iButton list if match is found AutoGeofence zone is disabled Priority Priority of generated event which will be applied to saved record Enter Event Event generation on Geofence entrance Exit Event Event generati...

Page 43: ...ered This event can be triggered by Green Driving OverSpeeding Authorized Driving Immobilizer Trip start stop Geofence AutoGeofence I O event When any of the above events is triggered FM1100 sends a configured SMS message to a defined phone number If SMS events is activated but there are no numbers defined in SMS events PreDefined Numbers list figure 1 then the device will not send any messages ...

Page 44: ...tal Input 1 reaches High level with priority High and configured to generate event on both range enter and exit figure 2 then the sent SMS is 2012 6 7 12 00 00 Digital Input 1 Figure 40 Configured Digital Input 1 SMS event The SMS Text field can be altered and any text can be entered Maximum message length is 90 symbols numbers letters and symbols in ASCII except for comma ...

Page 45: ...rios will automatically appear near the SMS event window figure 3 Note that Green Driving can t work together with Over Speeding and Authorized Driving can t work together with Immobilizer scenario only one of them could be enabled After enabling SMS events different message texts can be written for different scenarios Figure 41 Scenarios SMS event configuration When any of the scenarios events oc...

Page 46: ...n Exit On Enter or On Both figure 5 If No Event is selected then it is not possible to turn on SMS events If several zones are created then SMS events can be turned on separately for each zone entering different text message Figure 43 Geofence SMS event configuration AutoGeofence SMS events for AutoGeofence are configured the same as in Geofence AutoGeofence and its SMS event configuration is next...

Page 47: ...hosen Monitoring does not generate event so SMS event could not be configured Every IO element SMS event can be configured to send individual message to different numbers Figure 45 I O SMS event configuration 5 16 I O settings When no I O element is enabled AVL packet comes with GPS information only After enabling I O element s AVL packet along with GPS information contains current value s of enab...

Page 48: ... 0 500 15 HDOP 2 Probability 10 0 500 16 Odometer Value Virtual Odometer 4 Distance between two records m 17 Sleep mode 1 0 not deep sleep mode 1 GPS sleep mode 2 deep sleep mode 18 Cell ID 2 GSM base station ID 19 Area Code 2 Location Area code LAC it depends on GSM operator It provides unique number which assigned to a set of base GSM stations Max value 65536 20 Movement Sensor 1 0 not moving 1 ...

Page 49: ...d FM1100 records only GPS coordinates Priority AVL packet priority can be low high or panic Regular packets are sent as Low priority records When low priority event is triggered FM1100 makes additional record with indication that the reason for that was I O element change When High priority is selected module makes additional record with high priority flag and sends event packet immediately to the...

Page 50: ...ng up I O parameters as it is shown below Figure 47 I O settings 5 16 2 Event Generating Events happen when the value of enabled I O intersects thresholds enter exit or on both predefined by High and Low level thresholds Table below defines all available values of I O settings Setting Value Priority low high High level maximum threshold Low level minimum threshold Generate event on interval enter ...

Page 51: ...leep mode and user tries to send SMS message it cannot arrive to FM1100 device because GSM GPRS module is disabled most of the time wake up depends on Send Period parameter FM1100 will receive the SMS when it wakes up exits deep sleep mode 6 1 SMS command list Command Description Response getstatus Modem Status information Yes getweektime Current device time Day of Week and amount of minutes passe...

Page 52: ...st 20 operator codes 2 send from 21st to 40th operator codes 3 send all other operator codes sn Static navigation 1 enable 0 disable Yes banlist Banned operators information Yes crashlog Device last information before unexpected reset Yes delete_all_sms Deletes all SMS No setsimslot SMS forced SIM switching 0 SIM 1 1 SIM 2 No getsimslot SIM 1 SIM 2 info Yes 6 1 1 getstatus Response details Descrip...

Page 53: ...1 DOW 4 Time 12 58 Weektime 6538 6 1 3 getops Response details Description LIST Returns list of current available allowed operators Example GSM OP LIST 0 24602 6 1 4 getcfgtime Response details Description Date Time Returns last performed configuration date and time Example Last Configuration was performed on 2010 4 15 5 45 19 6 1 5 getgps Response details Description GPS Indicates valid 1 or inva...

Page 54: ...umber of Sent Records BR Number of broken records CF Profile CRC Fail counter FG Failed GPRS counter FL Failed link counter UT UPD Timeout counter SMS Sent SMS Counter NOGPS No GPS Timer GPS GPS receiver state 0 OFF 1 restarting 2 ON but no fix 3 ON and operational 4 sleep mode SAT Average satellites RS Reset Source Identification 1 Low Power 2 W Watchdog 3 I Watchdog 4 Software reset 5 Power On 6...

Page 55: ...umber 8 Parameter List Example setparam 1245 127 0 0 1 will change configured IP address 6 1 13 getparam 1271 X 212 X X values can be 1 2 3 If X 1 Operator codes from 0 19 are read from configuration and sent via SMS If X 2 Operator codes from 20 39 are read from configuration and sent via SMS If X 3 Operator codes from 40 49 are read from configuration and sent via SMS If X any other Operator cod...

Page 56: ...rds to send GPRS Enabled State of the GPRS connection 0 disabled 1 enabled Time Sync Indicates time synchronization on the device 0 not synchronized 1 synchronized Example FLUSH SMS Accepted 11 records found on FLASH Minimum Records to Send 1 GPRS Enabled 1 Time Sync 1 6 1 17 sn Enables or disables Static navigation 1 enable 0 disable 6 1 18 banlist Gives a list of all banned operators Example whe...

Page 57: ...minal choose baud rate 115200 and hardware control none Select COM port which is assigned to Virtual COM Port Click on Start Log button and save a new file Then click Connect to start receiving messages from FM1100 Also you can log NMEA data directly To get NMEA data simply enter the following command into the command field log_nmea 1 0a F 8 Parameter List 8 1 Parameters value types S8 Signed Char...

Page 58: ...aximum value Recommended value Goes with depends on parameters Value type 1 3600 U8 8 2 3 Analog Input value range ID 1001 Analog input measuring resolution and range can be defined as 0 10V value 0 or 1 30V value 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 8 2 4 Stop Detection Source ID 1002 Device can operate and change its working mode accor...

Page 59: ...259200 U32 8 3 3 Server Response Timeout ID 1012 Defines time period in seconds for server response to sent records Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 300 U8 ATTENTION Some GSM operators may disconnect the device from an active data link if the device doesn t send any data for a very long time even if active data link timeout is set to maximu...

Page 60: ... SIM1 ID 1243 Parameter defines APN username In case operator does not use username for login value should be empty Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 30 char string GPRS content activation SIM1 ID 1240 APN Name SIM1 ID 1242 APN Password SIM1 ID 1244 S8 30 8 4 4 APN Password SIM1 ID 1244 Parameter defines APN password In case operator doe...

Page 61: ...ID 209 Parameter defines GPRS data transport protocol Module can use TCP or UDP transport protocol to send data to server For TCP protocol value is 0 for UDP protocol value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 GPRS content activation SIM1 ID 1240 U8 8 4 9 GPRS content activation SIM2 ID 202 Parameter allows or does not allow GPRS usage I...

Page 62: ...242 APN username SIM1 ID 1243 S8 30 8 4 13 SMS Login ID 1252 User login is used to ensure module security Used in every SMS that is sent to device Example ba321 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char SMS Password ID 1253 S8 5 8 4 14 SMS Password ID 1253 User password is used to ensure module security Used in every SMS that is sent to d...

Page 63: ...e Number must be entered without or 00 Example 37060012346 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 digit 16 digits S8 17 8 4 19 Operator List for SIM1 ID 1271 X Parameter defines operator list According to this list module selects operating profile GSM operator codes are comma separated First in a list is Home Operator Code then Preferred Roaming ...

Page 64: ...D 1544 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 GPRS Week Time ID 1545 U8 8 5 1 3 Send Period ID 1544 This parameter indicates frequency time interval in seconds of sending data to server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1543 GPRS Week Time ID 1545 U32 8 5 ...

Page 65: ...interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Distance ID 1551 Min Angle ID 1552 GPRS Week Time ID 1555 U32 8 5 2 2 Min Distance ID 1551 This parameter indicates distance in meters in order to acquire new record Record is stored w...

Page 66: ... parameters 8 5 3 1 Min Period ID 1560 This parameter indicates time interval in seconds in order to acquire new record If value is 0 it means no records by min period will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 U32 8 5 3 2 Min Saved Records ID 1563 This parameter defines minimum number of records in one data packet that can be s...

Page 67: ... Week Time ID 1575 U32 8 5 4 3 Min Angle ID 1572 This parameter indicates angle in degrees in order to acquire new record If angle difference between last recorded coordinate and current position is greater than defined value new record is stored This parameter is operational when speed is higher than 10km h If value is 0 it means no records by min angle will be saved Minimum value Maximum value R...

Page 68: ...igher priority than Data Send Period ID 1584 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 GPRS Week Time ID 1585 U8 8 5 5 3 Send Period ID 1584 This parameter indicates frequency time interval in seconds of sending data to server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records I...

Page 69: ... records by min angle will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 180 Min Period ID 1570 Min Angle ID 1572 GPRS Week Time ID 1575 U16 8 5 6 4 Min Saved Records ID 1593 This parameter defines minimum number of records in one data packet that can be sent to server It has higher priority than Data Send Period ID 1594 Minimum value Maximum v...

Page 70: ...out triggering harsh braking event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25 0 85 0 35 Digital Output No 1 usage scenarios ID 1600 Float 8 6 3 Max Angular Velocity ID 1604 It is max allowed cornering angle which can be reached while cornering without triggering harsh cornering event Minimum value Maximum value Recommended value Goes with depends ...

Page 71: ...ate event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 65535 Trip ID 1280 U16 8 6 9 Trip Continuous distance counting ID 1283 For this feature I O 11 ODOMETER must be enabled If I O ODOMETER is enabled and Continuous distance counting variable is set to Continuous value 1 TRIP distance is going to be counted continuously from TRIP start to TRIP stop an...

Page 72: ...ng zone value 2 d On both value 3 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 3 All Geofencing parameters U8 8 6 10 5 Geofence Zone 1 Longitude X1 ID 1033 Parameter has two meanings dependent on zone shape If shape is a rectangle then ID 10333 is left down corner X coordinate If shape is a circle then ID 1033 is center of that circle X coordinate Samp...

Page 73: ...036 is not used Minimum value Maximum value Recommended value Goes with depends on parameters Value type 90 90 All Geofencing parameters Float Other 4 GeoFence zone s parameters have the same logic as shown in GeoFence Zone 1 GeoFence Zone Number Geofence Zone s parameters 1 1030 1036 2 1040 1046 3 1050 1056 4 1060 1066 5 1070 1076 8 6 11 AutoGeofencing 8 6 11 1 Enable Disable ID 1101 Enable value...

Page 74: ... ID 1103 U8 8 6 11 6 Radius ID 1105 Parameter represents radius of circle with center device coordinates after activating AutoGeofence feature Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1000000 100 Enable Disable ID 1101 Deactivate by ID 1100 U32 8 6 12 iButton List ID 1610 1659 Read 5 4 4 Minimum value Maximum value Recommended value Goes with depen...

Page 75: ...ue Maximum value Recommended value Goes with depends on parameters Value type 2147483648 2147483647 1 I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 Low level ID 1303 I O 1 logic operand ID 1304 I O 1 averaging length ID 1305 S32 8 7 4 I O 1 Low level ID 1303 Parameter defines low value of triggered I O property This parameter is used to set thresholds for I O properties to generate...

Page 76: ... operand ID 1304 S32 Other I O property elements can be configured in same logic All I O element parameters are listed in the next table I O Element Number I O element parameters I O 0 Digital input 1 1300 1305 I O 1 Digital input 2 1310 1315 I O 2 Digital input 3 1320 1325 I O 3 Analog input 1330 1335 I O 4 Digital output 1 1340 1345 I O 5 Digital output 2 1350 1355 I O 6 PDOP 1360 1365 I O 7 HDO...

Page 77: ... I O element SMS events can be configured in same logic All I O element SMS event IDs are listed in the next table Element name default SMS Event Text ID Digital Input 1 100 Digital Input 2 101 Digital Input 3 102 Analog Input 103 Digital Output 1 104 Digital Output 2 105 GPS PDOP 106 GPS HDOP 107 External Voltage 108 GPS Power 109 Movement Sensor 110 Odometer Value 111 GSM Operator 112 Speed 113 ...

Page 78: ... Driving 125 OverSpeeding 126 Authorized Driving 127 Immobilizer 128 Trip 129 Geo Zone 1 130 Geo Zone 2 131 Geo Zone 3 132 Geo Zone 4 133 Geo Zone 5 134 Auto Geofence 135 Reserved 136 Reserved 137 Reserved 138 Reserved 139 ...

Page 79: ...he first position most electronics of the vehicle are available Check if power is still available when you turn off any of vehicles devices Ignition is connected to the ignition relay output As alternative any other relay which has power output when ignition is on may be chosen 9 4 Connecting Ground Wire Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame If th...

Page 80: ...rees GPS antenna must be placed sticker facing down Figure 52 Correct GPS antenna mounting It is recommended to place GPS antenna behind dashboard as close to the window as possible A good example of GPS antenna placement is displayed in a picture below area colored green Figure 53 Correct placement of FM1100 9 6 Module Installation Module should not be seen or easily reached Module should be firm...

Page 81: ... 2012 02 02 0 18 Corrections in Terminal screen 17 2012 02 03 0 19 Corrected Min Max Values of Active Data Timeout APN APN Username Operator list Min Period Min send period start speed max cornering velocity frame border For Circle X2 High level Low level Average name from Max Conering Angle to Max Angular Velocity enable disable autogeofencing parameters values Added new SMS command readops 18 20...

Page 82: ...s in chapters 8 5 6 1 8 5 6 2 and 8 5 6 3 28 2013 01 17 1 28 FM1100M and FM1100M 2SIM versions support added 29 2013 03 13 1 29 AIN measurement error and additional error values added 30 2013 07 18 1 31 Updated I O settings ...

Reviews: